Sequental cum combination timer with rs-232 communication (12 pages)
Summary of Contents for Novatek-electro RN-16TM
Page 1
NOVATEK-ELECTRO LTD Research-and-Manufacture Company RN-16TM LIGHT-SENSITIVE MULTIFUNCTIONAL DAILY-WEEKLY TIMER SERVICE MANUAL www.novatek-electro.in...
Page 2
Output terminals of the RN-16TM may commutate the power load up to 3,5 kW (16A). If total power load connected to the RN-16TM is more than 3,5 kW (16A) then it will be necessary to commutate the required power load with a use of appropriate contactor NOVATEK-ELECTRO RN-16TМ...
- 3 - (magnetic starter). The RN-16TM should operate with the magnetic coil of contactor and thus the required power load will be turned ON/OF. Please kindly note that the contactor is not a part supplied along with the RN-16TM.
The mains power supply 240V 50Hz should be connected to «(1-1) – (2-2)» terminals of the RN-16TM. For wiring convenience terminals 1-1 are the one connection point and 2-2 terminals - another connection point. Output contacts have changeover relay 3 – 4.
LED light “ON” in the left upper corner of the front panel (Figure 1; point – 1). Current operation mode of the RN-16TM is marked by green LEDs “F”, “U”, “H” on the front panel (Figure 1; point – 7).
Page 6
Wednesday at 6:00 in the morning. So when voltage disappeared contacts 3-4 opened. As soon as the power load restore and return back to normal values RN-16TM will turn ON the power load again but according to the preprogrammed schedule of operation. So at 6:00 when the power return –...
Page 7
Notes: To set the time it’s necessary to input all digits including “0”. For example 7:35 morning time should be set as 07:35. After setting the schedule of events for RN-16TM it’s necessary to connect the power load to the output contacts of RN-16TM.
Page 8
◄► Set the voltage 9 Press and while keeping 221.5 button pressed set the shown on voltmeter (blinking dot) required value, then release the button when the setting is done NOVATEK-ELECTRO RN-16TМ...
(blinking dot) required value, then release the button when the setting is done 19 Press and save the Press and exit the dE.55 selected value in the menu (blinking dot) device memory (Save and Exit) 3. CURRENT TIME SETTING NOVATEK-ELECTRO RN-16TМ...
(blinking to current of minutes minutes position) 9 Press and Exit the menu CLOC if the time was set successfully 4. SETTING THE TIME SCHEDULE 1 Perform steps CLOC previous section 3. ◄► 2 Select Е01. item Е01._ NOVATEK-ELECTRO RN-16TМ...
Page 11
Luxmeter ON and expose to equally lightened surface or wall. Make sure that there are no undesired shadows on it. Then set the the values shown on Luxmeter into the RN-16TM according to the point 3 of section “5”.
Page 12
(those that are valid and the deleted (not active events) settings also). To set the time schedule for the RN-16TM it’s recommended to prepare first such a table and then to preprogamm the device.
Page 13
IF THE POWER LOAD IS MORE THEN 16A (3.5 KW). THE RELAY MUST OPERATE WITH THE POWER LOAD USING THE ADDITIONAL MAGNETIC CONTACTOR THAT WILL COMMUTATE ANY REQUIRED POWER LOAD NOTES: TERMINALS 3 AND 4 MAY BE USED IN THE SIGNALIZATION CIRCUITS NOVATEK-ELECTRO RN-16TМ...
–45 to +75 ºC and exposed to no more than 80% of relative humidity when there are no fumes in the air that exert a deleterious effect on package and the RN-16TM material. The Buyer must provide the protection of the timer against mechanical damages in transit.