User’s & Technical Manual – SIGHTGLASS LED LUMINAIRE SL60 PRECAUTIONS! There are no serviceable parts inside the SL60 unit. Not to be opened by any unauthorized person. All repairs to the device must be carried out by the manufacturer, or a qualified service engineer.
Any defect caused by modification, alteration, abuse, misuse or incorrect installation. Any defect of the product caused by improper repair by third party other than GELEC and GELEC's authorized distributors. Any incompatibility of the products with subsequent technical innovations or ...
This manual is a complete guide to the SL60 with information on unit user maintenance, unit installation and instructions on how to operate it. Do not touch any part of the SL60 the manual does not cover. Keep the manual for immediate reference. It should help in solving any operational questions you may have.
SIGHTGLASS LED LUMINAIRE SL60 GENERAL DESCRIPTION SL60 is a powerful and compact LED luminaire, for sightglasses to DIN28120 / 28121 / 11851 in safe areas. The optimum solution for the internal illumination of tanks, pipelines, silos, mixers and any closed vessel in industry that requires visual inspection during process stages.
Page 8
User’s & Technical Manual – SIGHTGLASS LED LUMINAIRE SL60 MAIN FEATURES High intensity illumination with low power consumption. Appropriate for high temperature applications and IP65 protection. Customized solutions and material alternations according your needs. Independent of vessel’s internal pressure/vacuum.
User’s & Technical Manual – SIGHTGLASS LED LUMINAIRE SL60 ADAPTING FLANGES The sandblasted stainless steel (AISI 304) adapting flanges are the mounting component between the luminaire and the sightglass. Permanite sealing gaskets waterproof the luminaire housing and provide thermal insulation from the vessel’s temperature, giving the ability to use the luminaire in difficult industrial conditions.
Page 10
User’s & Technical Manual – SIGHTGLASS LED LUMINAIRE SL60 TYPE Bxx* - DIN28120 (DN80-DN200) This flange is appropriate only for DIN28120 sightglasses. It has a common shape for these applications and with two mounting fins provides extra stability in vibrating environment.
Page 11
User’s & Technical Manual – SIGHTGLASS LED LUMINAIRE SL60 TYPE Cxx* - DIN11851 (DN50 & DN65) Flange appropriate for DIN11851 sightglasses with nominal diameter DN50 and DN65. Note that this flange covers the whole glass and it is appropriate for sightglasses used only for lighting.
Page 12
60mm above the glass, depending on your sightglass dimensions and your application needs. Advise the below tables to find which SL60 adapting flange type, matches each sightglass standard and its nominal diameter. CUSTOMIZED TYPES...
User’s & Technical Manual – SIGHTGLASS LED LUMINAIRE SL60 SL60 VERSIONS AND ORDERING Below are the main versions of SL60, which combine with one of the adapting flanges. - SL60 MAIN VERSIONS - SL60-WW100 SL60-WW200 SL60-WW300 Operating voltage 15..27 V AC , 12..40 V DC...
SIGHTGLASS LED LUMINAIRE SL60 INSTALLATION If any liquid spills into the SL60 cabinet, disconnect the unit immediately. Have the unit checked by a qualified service engineer before using it again. Always follow the instructions given by the manufacturer and use the SL60 in accordance to its specifications.
Page 15
User’s & Technical Manual – SIGHTGLASS LED LUMINAIRE SL60 Follow the below steps for the correct mounting of the SL60 luminaire. Ensure that you have all parts of the package as shown at the exploded view of the luminaire. Note that some steps of this procedure may have already been done from the manufacturer.
Page 16
User’s & Technical Manual – SIGHTGLASS LED LUMINAIRE SL60 INSTALLATION ON THE SIGHTGLASS The drawings are according to DIN standards, but consider them as indicative. There may be differences between different sightglass manufacturers. Always advise the manufacturer’s mechanical drawings of your sightglass before drilling a sightglass and ensure that any modifications will not affect its safety and operating standards.
User’s & Technical Manual – SIGHTGLASS LED LUMINAIRE SL60 PHOTOMETRIC DATA Sightglass LED Luminaire SL60-WW100 Lamp: Warm White 2600-3700 K Lamp Output: 1 lamp, rated Lumens: 100 Input Wattage: Photometry: Type C CIE Class: Direct Cutoff Class: 5 x 5...
Page 21
User’s & Technical Manual – SIGHTGLASS LED LUMINAIRE SL60 Sightglass LED Luminaire SL60-WW200 Lamp: Warm White 2600-3700 K Lamp Output: 1 lamp, rated Lumens: 200 Input Wattage: Type C Photometry: Direct CIE Class: Cutoff Class: 5 x 5 Nema Type:...
Page 22
User’s & Technical Manual – SIGHTGLASS LED LUMINAIRE SL60 Sightglass LED Luminaire SL60-WW300 Lamp: Warm White 2600-3700 K Lamp Output: 1 lamp, rated Lumens : 300 Input Wattage: Type C Photometry: Direct CIE Class: Cutoff Class: 5 x 5 Nema Type:...
User’s & Technical Manual – SIGHTGLASS LED LUMINAIRE SL60 TECHNICAL SPECIFICATIONS TECHNICAL DATA Dimensions L x W x H (mm) 60 x 60 x 50 / (2.36 x 2.36 x 1,96 in) Weight (depending on adapting flange) 780 / 960 gr.
And the following European Harmonized Standards have been applied: CE, EN60598 EEC NORMS The product “P/I LEVEL TRANSDUCER” type “SL60” is designed and produced by the manufacturer “GELEC Co. LP” to be in compliance with the EEC norms applying to it. GELEC Industrial Electronics PAGE 25...