Page 1
POSITION CONTROLLER WITH POSITIVE AND NEGATIVE QUOTAS, HB 237.16 AND MANAGEMENT OF 8 OUTPUTS PROGRAMMABLE WITH UP TO 9 PROGRAMS (OHFWURQLF ,QVWUXPHQW 2 3 7 H 1 6 User Manual Supplement to "Installation, maintenance and servicing manual"...
You are urged, therefore, to read the manual carefully and, if you have any queries, to contact QEM for further explanations by sending the assistance fax contained in the manual.
1 - 3 RESPONSIBILITY AND VALIDITY RESPONSIBILITY QEM declines all responsibility for any injury to persons or damage to things resulting from the failure to observe the instructions and rules in this manual and the "Installation, maintenance and servicing manual". It is furthermore specified that the customer/purchaser is bound to use the instrument according to the instructions provided by QEM and, if any doubts arise, to send a written query to QEM.
1 - 4 DESCRIPTION OF OPERATION The instrument HB 237.16 controls the position of one axis and governs the activation and de-activation of 8 totally programmable outputs. The quotas for each single output can be set in a maximum of 9 programs that can be called only from the keyboard.
Page 7
HB 237.16 Quality in Electronic Manufacturing CHAPTER 2 OPERATOR/MACHINE INTERFACE Description of keyboard Description of inputs Description of outputs Pag. 7 di 27...
HB 237.16 Quality in Electronic Manufacturing 2 - 1 DESCRIPTION OF KEYBOARD Function Normal operation: Pressed for one second, gives access to choice of program to be executed. Data input: confirms the displayed data. Normal operation: not used. Data input: resets displayed data to zero.
HB 237.16 Quality in Electronic Manufacturing 2 - 2 DESCRIPTION OF INPUTS Characteristics of inputs Refer to the chapter entitled "Electrical characteristics" in the "Hardware stgructure" booklet enclosed with this manual. Operating logic Activation mode Name Polarizer Description Programmable input 1. Its function depends on the type of programming made in the "FI" set-up parameter.
Page 10
HB 237.16 Quality in Electronic Manufacturing COUNT INPUTS Name Operating logic Polarizer Description N / P "Phase 1" input incremental transducer. N / P "Phase 2" input incremental transducer. For details of the count inputs, refer to the chapter entitled "Electrical characteristic" in the "Hardware structure"...
Page 11
HB 237.16 Quality in Electronic Manufacturing Charatteristics of output expansions (option L6 or U6) Refer to the chapter entitled "Electrical characteristics" in the Hardware structure" booklet enclosed with this manual. Minimum activation Operating logic Name Polarizer time [ms] Descrizione Quota 3. With set-up parameter "L3" set on "0", the output is activated when the count reaches the value of the quota set as parameter "3"...
HB 237.16 Quality in Electronic Manufacturing CHAPTER 3 SETTING UP FOR OPERATION Programming (set-up) Pag. 12 di 27...
Page 13
HB 237.16 Quality in Electronic Manufacturing 3 - 1 SET-UP As these parameters set the operating mode of the instrument, access is restricted to the installer only; a password must be entered for access to programming as follows: Description Keyboard Display Access the set-up programming.
Page 14
HB 237.16 Quality in Electronic Manufacturing FUNCTION DISPLAY DESCRIPTION 0 = No function. 1 = Continuous loading of the preset quota. 2 = Impulse loading of the preset quota on the count when input I1 is activated. 3 = Impulse loading of the preset quota on the count when input I1 is de-activated.
Page 15
HB 237.16 Quality in Electronic Manufacturing FUNCTION DISPLAY DESCRIPTION Preset Quota This is the value loaded on the count when input I1 is activated or I 1 2 3 4 Min. -99999 the CLEAR key is pressed when the parameter "FC" is set on "2".
Page 16
HB 237.16 Quality in Electronic Manufacturing FUNCTION DISPLAY DESCRIPTION 0 = Output disabled. 1 = The output is activated when the count is equal to or greater than the value introduced in the work program (quota 2). The count increases (UP).
Page 17
HB 237.16 Quality in Electronic Manufacturing FUNCTION DISPLAY DESCRIPTION These displays appear if the parameter "Expansion enabling" is set on 1 0 = Output disabled. 1 = The output is activated when the count is equal to or greateer than the value introduced in the work program (quotas 3÷8).
Page 18
HB 237.16 Quality in Electronic Manufacturing FUNCTION DISPLAY DESCRIPTION These displays appear if the parameter "Expansion enabling" is set on 1 0 = Output U3 is normally de-activated. Output U3 logic status 1 =Output U3 is normally activated. 0 = Output U4 is normally de-activated.
Page 19
HB 237.16 Quality in Electronic Manufacturing CHAPTER 4 Work programs and auxiliary functions Operation graphs and tables Pag. 19 di 27...
HB 237.16 Quality in Electronic Manufacturing 4 - 1 WORK PROGRAMS AND AUXILIARY FUNCTIONS INTRODUCING A SINGLE WORK PROGRAM (SET-UP "nP" SET ON "1") Description Keyboard Display Access introduction of work program. 2 3 4 5 × 2 sec. Example with set-up parameter "FU1" set on "1".
Page 21
HB 237.16 Quality in Electronic Manufacturing INTRODUCING MORE THAN ONE WORK PROGRAM (SET-UP "nP" > DI "1") Description Keyboard Display Access to introduction of work programs. P r n r 1 × 2 sec. A request is made to introduce the program in which to enter the the = ON new work quotas (max.
Page 22
HB 237.16 Quality in Electronic Manufacturing Description Keyboard Display The request is made to introduce the delta for activating the third 3 d 1 2 3 output enabled in set-up (min. 0 - max. 9999). The operator can introduce its value and confirm with ENTER.
Page 23
HB 237.16 Quality in Electronic Manufacturing INTRODUCING A VALUE ON THE COUNT It is possible to modify the value of the count displayed by the instrument (axis position) by introducing the required value. This function is especially useful during installation and calibration.
Page 24
HB 237.16 Quality in Electronic Manufacturing 4 - 2 OPERATION TABLES AND GRAPHS OUTPUT FUNCTIONS GRAPH Pag. 24 di 27...
Page 25
HB 237.16 Quality in Electronic Manufacturing OUTPUT FUNCTIONS GRAPH Pag. 25 di 27...
HB 237.16 Quality in Electronic Manufacturing CHAPTER 5 ASSISTANCE Input and output troubleshooting How to complete the technical assistance fax form Warranty Pag. 26 di 27...
We need your help if we are to provide you with a quick, efficient and high-quality service. Whenever you need the assistance of QEM in dealing with any technical problems that may arise in your applications and the problem persists even though all the instructions in the "Installation, maintenance and servicing manual"...
Page 28
HB 237.16 Quality in Electronic Manufacturing SPACE FOR YOUR NOTES Pag. 28 di 27...