Water Heater Preparation
2. Remove the four mounting screws and plastic washers
bottom of the water heater and retain for use in the next step.
3. Install the two L brackets ⑤ to the bottom of the water heater with the
screws and washers
face to the outside of the water heater.
Pipe Cover Installation
4. Temporarily fit the pipe cover enclosure to the L brackets ⑤, using two
screws ⑦ (one per side). DO NOT fully tighten the screws as they will be
removed again in a later step.
5. Loosen the screws of the back bottom frame ① and move the frame into
its final position. Then, re-tighten the screws.
6. Select two suitable fixing points through the back of the bottom frame ①
and mark off their position on the wall.
7. Remove the pipe cover enclosure from the water heater and drill two
holes in the wall as marked. If using the wall anchors ⑨ supplied, a 5 mm
(0.2 in.) diameter hole to the depth of 25 mm (1.0 in.) is required.
8. Gently tap the wall anchors ⑨ into the drilled holes until flush with the
wall surface.
9. Press plastic retaining clips ⑥ through the panel and into the
L bracket.
10. Refit and secure the pipe cover enclosure to the L brackets ⑤ using the
screws ⑦ and plastic washers ⑧.
11. Secure the pipe cover to the wall through the back bottom frame ① with
two screws ⑩.
Front Panel Installation
12. Attach the front panel ④ to the pipe cover enclosure by inserting
the four tab hooks on the front panel
left panel ② and right panel ③ (see tab hook and slot detail
below).
Insert Tab Into Slot
13. DO NOT perform the following instructions on Australian
installations: To secure the front panel ④ to the pipe cover
enclosure, open the four tabs at the top and bottom corners
and secure with screws ⑦and plastic washers ⑧ . Next, close the tabs.
NOTE: Some models do not include plastic covers, for these applications secure front panel to the pipe cover
enclosure with screws ⑦and plastic washers ⑧ .
Rinnai Corporation continually updates materials, and as such, content is subject to change without notice. Local, state, provin-
cial, federal and national fuel gas codes must be adhered to prior to and upon installation.
Pipe Cover Enclosure Installation Instructions
A
removed in step 2, ensuring the tab of the L brackets
B
into the slots
Tab Fully Inserted
Into Slot