Installing solar photovoltaic systems requires specialized skills and knowledge. The installer assumes all risk
of injury, including risk of electric shock. Module installation should be performed only by a qualified installer.
All modules come with a permanently attached junction box and 4mm²wire. Jayu Solar can provide
customers with fitted cables for ease of installation, if desired.
When disconnecting wires connected to a photovoltaic module that is exposed to sunlight, an electric arc
may occur. Arcs can cause burns, start fires or otherwise create safety problems. Exercise caution when
disconnecting wiring on modules exposed to sunlight.
Photovoltaic solar modules convert light energy to direct-current electrical energy, and are designed for
outdoor use. Proper design of support structures is the responsibility of the system designer and installer.
Do not attempt to disassemble the module, and do not remove any attached nameplate
or components. Doing so will void the warranty.
Do not use mirrors or other hardware to artificially concentrate sunlight on the module.
Safety precautions for installing a solar photovoltaic system
Solar modules produce electrical energy when light shines on the front surface. The DC voltage may exceed 30V.
If modules are connected in series, the total voltage is equal to the sum of the individual module voltages. If
modules are connected in parallel, the total current is equal to the sum of individual module current
Keep children well away from the system while transporting and installing mechanical and electrical
components.
Completely cover the module with an opaque material during installation to keep electricity from being
generated.
Abide with the safety regulations for all other components used in the system, including wiring and cables,
connectors, charging regulators, inverters, storage batteries and rechargeable batteries, etc.
Use only equipment, connectors, wiring and support frames suitable for use in a solar electric systems.
Always use the same type of module within a particular photovoltaic system.
Modules rated for use in this application class may be used in systems operating at greater than 50V DC or
240W, where general contact access is anticipated. Modules qualified for safety through this part of
IEC61730 and IEC61730-2 and within this application class are considered to meet the requirements for
safety classⅡ. Under normal conditions, a photovoltaic module is likely to experience conditions that
produce more current and/or voltage than reported at standard test conditions. Accordingly, the value of Isc
and Voc marked on this module should be multiplied by of 1.25 when determining component voltage ratings,
conductor current ratings, fuse sizes, and size of controls connected to the PV output.
The recommend maximum series fuse is 15A(156 module).
The modules have been evaluated for a maximum positive loading of 5400pa.
Do not wear metallic rings, watchbands, ear, nose, or lip rings, or other metallic devices
while installing or troubleshooting a photovoltaic systems.
Be sure to use appropriate safety equipment (insulated tools, insulated gloves, etc) approved
for use in electrical installations.
Application class A: meet the requirements for safety class II.
North of Peigong Road, East of Hankang Road, Peixian Economic,Development Zone, Xuzhou City, Jiangsu Province, 221000, P.R. China
Website:
www.jayusolar.com
1/13
Xuzhou Jiayu Solar Energy Technology Co.,Ltd.
Email: ranfeng@jayusolar.com
Installation Manual
Tel: +86 13151232006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JY360M6-Aa-5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Jayu JY360M6-Aa-5

  • Page 1 Module installation should be performed only by a qualified installer. All modules come with a permanently attached junction box and 4mm²wire. Jayu Solar can provide customers with fitted cables for ease of installation, if desired.
  • Page 2: Mechanical Installation

    Installation Manual MECHANICAL INSTALLATION Selecting the location Select a suitable location for installation of the module. The module should be face sun, reduce loss from exterior sunshine and raise export power. Detailed information on optimal module orientation will depend on the sunlight and specific system design. For the optimal annual output from the solar module, we suggest the mounting angle be equal to the latitude of the city where the modules are being installed.
  • Page 3: Dimensions (Mm)

    Installation Manual Figure1: Jayu Solar Module installed with screw fitting method Chart 1 Mono&Poly-silicon module mechanical drawing Dimensions(mm) Module type Cell quantity 6*12 1956*992 1676 1176 6*12 1956*992 1676 1176 6*10 1650*992 35\40\50 1370 6*10 1650*992 1370 6*10 1640*992 35\40\50...
  • Page 4: Clamp Fitting

    Installation Manual Module can be mounted on a horizontal or an inclined plane. We recommend type “M8” stainless steel screws fix up on the bracket which we already fix up. Insert screw into flat gasket, insert screw into installation hole both on the modules and supporting frame. Insert screw into flat gasket and spring gasket, then apply nut on the screw and tighten securely.
  • Page 5 Installation Manual Chart 2 The Guide for Fixing Modules Cell Dimensions(mm) Module type Module quantity 0.5~2 2.5~3 JYXXXM6-Aa-5 6*12 1956*992 156 Mono-silicon JYXXXM6-Ab-5 6*10 1640*992 0.5~2 2.5~3 White JYXXXM6-Ac-5 1482*992 0.5~2 2.5~3 0.5~2 2.5~3 JYXXXM6-Ad-5 1325*992 JYXXXP6-Aa-5 0.5~2 2.5~3 6*12 1956*992 JYXXXP6- Ab-5 0.5~2...
  • Page 6 Installation Manual According to installation position as shown in table2,put PV modules on the aluminum rails. Press clamps into the groove of aluminum rails. To ensure clamps is stuck. Use a mid-clamp connect 2 modules as shown in figure 2.Use an end-clamp to fix the edge module as shown in figure 1. Use hexagon screwdriver to tighten the clamp on the rail securely.
  • Page 7 Installation Manual Roof Mount When installing a module on a roof top or building, ensure that it is securely fastened and cannot fall as a result of wind or snow loads. Provide adequate ventilation under a module for cooling. A minimum air gap of 93mm is recommended between the modules and mounting surface.
  • Page 8: Electrical Installation

    Installation Manual Do not stand or step on module. Do not drop the module or allow objects to fall on the module. Do not place any heavy objects on the module. Inappropriate transport and installation may damage the module glass or frame. ELECTRICAL INSTALLATION Grounding There are ground holes and marking along either edge of the frame.
  • Page 9: Maintenance

    Caution: Electrical shock hazard! Do not touch bare conductors or other potentially energized parts. MAINTENANCE Jayu Solar recommends the following maintenance items to ensure optimum performance of the module: Clean the glass surface of the module as necessary. Use water and a soft sponge or cloth for cleaning. A mild, non-abrasive cleaning agent can be used if necessary.
  • Page 10: Disclaimer Of Liability

    No responsibility is assumed by Jayu Solar for any infringement of patents or other rights of third parties, which may result from use of the PV product. No license is granted by implication or otherwise under any patent or patent rights.
  • Page 11 Cell size Umpp Impp Pmpp Model (mm) (V) (A) (V) (A) (W) JY360M6-Aa-5 47.89 9.66 39.96 9.02 360.00 18.55 JY355M6-Aa-5 47.68 9.49 39.66 8.95 355.00 18.30 JY350M6-Aa-5 47.45 9.40 39.36 8.89 350.00 18.04 JY345M6-Aa-5 47.31 9.31 38.96 8.84 345.00 17.78 JY340M6-Aa-5 47.03...
  • Page 12 Cell size Umpp Impp Pmpp Model (mm) (V) (A) (V) (A) (W) JY355P6-Aa-5 48.53 9.41 39.31 9.03 18.30 JY350P6-Aa-5 48.35 9.33 39.02 8.96 18.04 JY345P6-Aa-5 48.19 9.25 38.88 8.88 17.78 JY340P6-Aa-5 47.89 9.19 38.64 8.81 17.52 JY335P6-Aa-5 47.59 9.13 38.40 8.73 17.26 JY330P6-Aa-5...
  • Page 13 Cell size Umpp Impp Pmpp Model (mm) (V) (A) (V) (A) (W) JY265P6-Ac-5 36.58 9.44 29.54 8.97 18.03 JY260P6-Ac-5 36.32 9.31 29.25 8.89 17.69 JY255P6-Ac-5 36.01 9.22 28.95 8.81 17.35 JY250P6-Ac-5 35.71 9.10 28.79 8.68 17.01 JY245P6-Ac-5 35.40 9.02 28.57 8.58 16.67 JY240P6-Ac-5...