Landmark Technic User Guide Signal Processor...
User Guide Landmark Technic Signal Processor Contents Introduction About this guide About the Landmark Technic Processor Unpacking the processor Nomenclature Specification Installation and Removal Fitting the unit onto a DIN rail Removing the unit from a DIN rail Electrical connections Cable connector assembly Using the Configurator Installation...
Page 6
Landmark Technic User Guide Signal Processor Fig. 1 Landmark Technic Signal Processor...
User Guide Landmark Technic Signal Processor Introduction 1.1 About this guide This guide gives the information necessary for you to operate a Landmark Technic Signal Processor. Information regarding installation is contained within the Installation Guide. More detailed information regarding servicing, repair and calibration of the processor is contained in the Service Manual.
Page 8
Landmark Technic User Guide Signal Processor no time function current output output scaling averager peak picker alarm alarm output emissivity track / hold config command RS 232 input serial i/o Fig. 2 LM Technic - Functional Block Diagram Page 2...
User Guide Landmark Technic Signal Processor Specification Input/output accuracy: <0.1% of span Input/output drift: <0.1% of span/°C Quantisation: 16 bit Sampling: 10ms Signal retransmission range: Adjustable over thermometer span (min 100°) Signal retransmission current: 0 to 20mA/4 to 20mA Signal update rate: 10ms Current output load inc.
Page 10
Landmark Technic User Guide Signal Processor DIN rail Clip onto DIN rail Sliding spring catch Fig. 3 Installing the LM Technic onto a DIN rail LMT010065 Use a screwdriver to unclip the spring latch Screwdriver Fig. 4 Removing the LM Technic from a DIN rail LMT010066 Page 4...
User Guide Landmark Technic Signal Processor Installation and Removal 3.1 Fitting the unit onto a DIN rail The LM Technic processor is designed to be mounted onto a standard DIN rail. To install the unit: Ensure that a suitable DIN rail (DIN EN 50 022) is available and installed correctly (refer to Appendix).
Page 12
Landmark Technic User Guide Signal Processor 3 4 5 L N 11 12 13 14 15 16 Live Neutral Twisted Screened Pair Twisted Twisted Pair Processor Processor Pair Supply (-) Supply (+) 6 core screened cable to IRT (Pigtails maximum length = 30mm) NOTE The LM Technic processor is designed to work with an a.c.
Page 13
User Guide Landmark Technic Signal Processor LM Technic Terminal Nº Wire Colour Function Yellow Signal input (+) from thermometer Blue Signal input (-) from thermometer White Emissivity output (+) to thermometer Screen Thermometer cable screen Thermometer power supply (+) Black Thermometer power supply (-) Green Emissivity return (-)
Page 14
Landmark Technic User Guide Signal Processor Remote switch Peak Picker Track & Hold Switch open Peak Pick Track Switch closed Reset Hold Note Remote switch can be replicated by voltage Vin. Where: >+3.0V = Switch open <+1.5V = Switch closed Fig.
Page 15
User Guide Landmark Technic Signal Processor 3.3.1 Alarm output connection schedule The Alarm output connection schedule is given in Fig. 5 and Table 1. The Alarm relay contact rating is 50V a.c. or d.c. at 0.1A. It is recommended that a twisted pair connection be used. 3.3.2 CMD (Command) input connection schedule The CMD (Command) input connection schedule is given in Fig.
Landmark Technic User Guide Signal Processor 3.4 Cable connector assembly The cable connectors for the processor are included in the processor package. Each cable connector must be correctly wired with the appropriate cable. (Refer to Section 3.3 for the cable schedules). To wire up the connector.
User Guide Landmark Technic Signal Processor Using the Configurator When the processor is connected to a System 4 thermometer, the processor must be configured for use with that particular thermometer and have its operating parameters set. The temperature measurement system (i.e. processor and thermometer) is most easily configured using the LM Technic Configuration Software and a suitable PC. It is also possible to use a PC running standard terminal software and an RS232 port to perform the configuration, allowing the individual commands to be used.
Page 18
Landmark Technic User Guide Signal Processor Configuration parameters can be stored to the LM Technic and/or can be downloaded to a file on the PC for later use. It is possible to use the software without an LM Technic, however, only file menus will be available. 4.2.1 Setting a new configuration in a processor New. Use the ‘File’, ‘New’, menu to load default data into the configuration area. Thermometer. In the configuration area, select the thermometer type from the list box to match the thermometer actually connected to the LM Technic.
Page 19
User Guide Landmark Technic Signal Processor 4.2.2 Editing a configuration in a processor Read. Use the ‘Read’ button to load data from the connected processor into the configuration area. In the configuration area, adjust parameters as described in 4.2.1. Apply. When the required configuration parameters have been en- tered, press the ‘Apply’ button to send the configuration data to the LM Technic. A summary of the data sent will appear in the live data, confirming that the data has been received by the LM Technic. 4.2.3 Saving/Opening a configuration file Save.
Page 20
Landmark Technic User Guide Signal Processor Adjustable decay rate 'Hold' mode 'ON' Delay Threshold level 'OFF' Delay 'Reset' mode Time Fig. 10 Graphical representation of the Peak Picker time function S4970092 Time Track Hold Track Hold Command Command signal = Closure of potential-free contacts, s/c = Hold TTL level (0 to 5V) +5V = Track...
User Guide Landmark Technic Signal Processor Time Function Processing 5.1 Peak Picker The Peak Picker function can be used to monitor the highest temperature measured by the thermometer. This feature is useful especially for moving targets and/or where the target is obscured partially e.g. a steel slab on a rolling mill where parts of the surface are covered with scale.
Landmark Technic User Guide Signal Processor LED Indicators LEDs A and B on the Landmark Technic give visual identification of internal operations of the unit. The following table lists the indications in order of precedence. LED A Colour Indication Amber Test mode Flashing Amber Volatile configuration Flashing Green Configurator connected Green LED B Colour Indication Sensor fail*** Flashing Red...
User Guide Landmark Technic Signal Processor Maintenance The Landmark Technic Processor is designed to be virtually maintenance free, but calibration checks are highly recommended at periods of not more than one year. For details on Landmark Technic calibration, please contact the Calibration department at Land Instruments International.
User Guide Landmark Technic Signal Processor APPENDIX B Serial Communications Set-up The Landmark Technic configurator port can be used for communication between the processor and either a terminal or a computer. NOTE It is recommended that configuration is normally performed using the configuration software provided. RS232C is standard and compatible with either terminals or computers which allows communications with a single processor only. RS485 - contact Land Instruments International.
Page 26
Landmark Technic User Guide Signal Processor B1 Serial Communications protocol B1.1 RS232C read data Computer/Terminal Landmark Technic Parameter value being requested (ASCII) Value or requested parameter (ASCII) Fig. 14 RS232C mode READ protocol LMT010075 B1.2 RS232C set data Landmark Technic Computer/Terminal Parameter value being modified...
Page 27
User Guide Landmark Technic Signal Processor B1.3 RS232C examples To read the temperature: Type at the terminal: RATMP [enter] Breakdown: Read mode Always A Command to report the temperature [enter] Press terminal enter key Reply: 1000 Temperature in degrees To set the emissivity to 0.500 Type at the terminal: SAEMS 500 [enter] Breakdown:...
Page 28
Landmark Technic User Guide Signal Processor B1.4 Serial Port Parameters Range Name Menu title text Default Comments Increment Thermometer List of available type thermometers ob- tained using IFO command. Note Changing IRT sets default parameters in other places. Emissivity 1000 1000 e.g.
Page 29
User Guide Landmark Technic Signal Processor Range Name Menu title text Default Comments Increment Mode 0 = Low 1 = High Level irt_ irt_ irt_max Value in de- grees Signal output 0 = 0 to 20mA type 1 = 4 to 20mA Signal output irt_tmax = value in Additional limit >irt_ < irt_ tmin tmax Tmax (20mA) degrees...
Page 30
Landmark Technic User Guide Signal Processor Range Menu title Name Increment Default Comments text Status flags Read only 0x0000 0xFFFF 0x0001 Function Command I/P Active Not active Under range Active Over range Active Obscured* Active Clipping** Active Sensor fail*** Active Alarm 1 Active Unclamped Ratio IRT only...
Page 31
User Guide Landmark Technic Signal Processor B1.5 System Communications Timing Data Command response time This is the time taken between the end of the last character of a command and the beginning of the first character of the reply. This time is independent of the selected baud rate. All commands are serviced within 20ms. Command reply time This is the time taken by the LM Technic reply.
Page 32
Landmark Technic User Guide Signal Processor Page 26...
Page 33
PRODUCT WARRANTY Thank you for purchasing your new product from Land Instruments International. This Land manufacturer’s ‘back-to-base’ warranty covers product malfunctions arising from defects in design or manufacture. The warranty period commences on the instrument despatch date from the Land Instruments International Ltd.
Page 34
PRODUCT WARRANTY EXCLUSIONS FROM WARRANTY It should be noted that costs associated with calibration checks which may be requested during the warranty period are not covered within the warranty. Land reserve the right to charge for service/calibration checks undertaken during the warranty period if the cause is deemed to fall outside the terms of the warranty.
Need help?
Do you have a question about the System 4 Landmark Technic Processor and is the answer not in the manual?
Questions and answers