RFGate
3.2
Wireless dual channel signal transmission system for safety edges
Original operating instructions
General
Receiver
Push
button
44
1
Safety instructions
Warning: Switch off the operating voltage before working on the
system. Only trained, qualified personnel may perform installation
and startup. The unit may only be repaired by the manufacturer. The
switching unit may only be used to protect against dangers on
crushing and shearing points and on automatic industrial doors and
gates (intended use). National and international regulations on
industrial door and gate safety must be complied with. Always
2
Common application
2.1
Sliding gate
Transmitter 1 (input 1) corresponds to receiver output 1
i
Transmitter 2 (input 1) corresponds to receiver output 2
Receiver
Transmitter 1
ON
1
2
DIP switch 2 ON
Transmitter 2
Receiver
24
75
Transmitter 2
ON
ON
1 2
1 2
not used
not used
Safety edge
Safety edge
8.2 kOhm
8.2 kOhm
Transmitter 1
Mobile safety edges
Transmitter
Batteries
Push
CR2032
button
22
Further transmitters with separate manuals
consider the safety functions of your application as a whole, never just in
relation to one individual section of the system. The installer is responsible
for carrying out a risk assessment and installing the industrial door system
correctly.
Battery life up to 2 years, but it is recommended
i
batteries are changed every 12 months.
2.2
Industrial door
Transmitter input 1 corresponds to receiver output 1
i
Transmitter input 2 corresponds to receiver output 2
Receiver
Transmitter
ON
1
2
DIP switch 2 OFF
Receiver
Contact
50
23
ON
Contact
1 2
(e.g.wicket door)
Safety edge
8.2 kOhm
Transmitter
Safety edge
370052A