Original operating instructions
General
Receiver
Push
button
44
1
Safety instructions
Warning: Switch off the operating voltage before working on the
system. Only trained, qualified personnel may perform installation
and startup. The unit may only be repaired by the manufacturer. The
switching unit may only be used to protect against dangers on
crushing and shearing points and on automatic industrial doors and
gates (intended use). National and international regulations on
industrial door and gate safety must be complied with. Always
2
Common application
2.1
Sliding gate
Transmitter 1 (input 1) corresponds to receiver output 1
i
Transmitter 2 (input 1) corresponds to receiver output 2
Receiver
Transmitter 1
ON
1
2
DIP switch 2 ON
Transmitter 2
Receiver
24
75
Transmitter 2
ON
ON
1 2
1 2
not used
not used
Safety edge
Safety edge
8.2 kOhm
8.2 kOhm
Transmitter 1
Mobile safety edges
Transmitter
Batteries
Push
CR2032
button
22
Further transmitters with separate manuals
consider the safety functions of your application as a whole, never just in
relation to one individual section of the system. The installer is responsible
for carrying out a risk assessment and installing the industrial door system
correctly.
Battery life up to 2 years, but it is recommended
i
batteries are changed every 12 months.
2.2
Industrial door
Transmitter input 1 corresponds to receiver output 1
i
Transmitter input 2 corresponds to receiver output 2
Receiver
Transmitter
ON
1
2
DIP switch 2 OFF
Receiver
Contact
50
23
ON
Contact
1 2
(e.g.wicket door)
Safety edge
8.2 kOhm
Transmitter
Safety edge
370052A
05/18
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Swissdoor RFGate 3.2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bircher Swissdoor RFGate 3.2

  • Page 1 370052A 05/18 RFGate Wireless dual channel signal transmission system for safety edges Original operating instructions General Receiver Transmitter Push Batteries Push button CR2032 button Further transmitters with separate manuals Safety instructions Warning: Switch off the operating voltage before working on the consider the safety functions of your application as a whole, never just in system.
  • Page 2 Transmitter DIP switch setting according to sensor (safety edge, switch contact) Example: RFGate 3.2.T Sensor connection DIP switch Sensor connection DIP switch Further instructions see separate transmitter manuals. Receiver Wiring: Power supply and outputs with control Power supply Outputs: Relay contacts are shown unpowered Conductor cross section 0.25 –...
  • Page 3 Installation sequence set-up Check DIP Install and wire Turn on power switch settings receiver supply Transmitter and receiver and Transmitter: Pairing (Chapter 6): further transmitters must be at insert transmitter with receiver least 0.5 m apart batteries Transmitter: Transmitter: System test: press install wire safety edge on gate or...
  • Page 4 Devices with this symbol must be treated separately during disposal. This must be done in accordance with the laws of the respective countries for environmentally sound disposal, processing and recycling of electrical and electronic equipment. Contact | Swissdoor ApS, Stenhuggervej 2, 5471 Søndersø, www.swissdoor.dk Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen, www.bircher-reglomat.com...