AMP RACK USER MANUAL Publication 372000-96 Rev H BURNERS IGNITERS DAMPERS CONTROLS www.forneycorp.com...
Page 2
All personnel should become thoroughly familiar with the contents of this manual before attempting to use the Forney AMP Rack. Because it is virtually impossible to cover every situation that might occur during operation and maintenance of the equipment described in this publication, personnel are expected to use good engineering judgment when confronted with situations that are not specifically mentioned herein.
GENERAL INFORMATION The Forney AMP Rack has 8 slots that can accommodate the RM-IDD, RM-DR6101E and/or RM-IDD9000 amplifiers. The AMP Rack is available with either a single, redundant AC input power supplies, or without power supplies. See Figure 1 below.
EQUIPMENT DESCRIPTION The AMP Rack will fit into any standard 19” EIA rack mounting hardware and is 10 units high. AMP Rack Component Weight Empty Rack 18 lbs Power Supply Module 6 lbs Power Bezel 1 lb Assembled rack w/2 PS...
L, N, and G power terminals NC, C, and NO dry contact terminals (used by BMS to monitor AMP Rack logic voltage level) The terminal block for both the power and dry contact is 6-position rated for 300V and 20 amperes.
DETECTORS, AMPLIFIERS AND BEZELS Each AMP Rack accepts up to (8) amplifiers. Any combination of the following may be used. AMP RACK AMPLIFIER SECTION BEZEL PART AMPLIFIER AMP PART NUMBER DETECTORS NUMBER IDD-II RM-IDD 358317-01 364740-01 IDD-IIU IDD-IIL IDD-II IDD-IIU...
404325-02 240 VAC / 240 VAC The AMP Rack has only 8 slots compared to 9 in the V-Rack. If the existing V-rack has 9 amplifiers installed, two (2) AMP Racks will be required. If an AMP Rack is used to replace an existing V-rack, the existing amplifiers and bezels may be re-used.
Maximum allowable shock conditions: 25 g for 30 ms. CAUTION: The storage facility shall be free from rodent or insect infestation. Rodents will chew through wiring and plastic. AMP Rack User Manual IDD Flame Detector Heads Manual 372000-96 Rev G...
Do not push any crates with a tow motor, fork truck, or any other device. Damage to the integrity of the crate may damage the equipment or the protective equipment packaging. Use caution when unpacking crates. Do not dislodge item tagging. AMP Rack User Manual 372000-96 Rev G...
SECTION 3 INSTALLATION The AMP Rack is a standard 19” width rack assembly. Attach with 4 bolts per side. The side flanges can be removed and installed in the back of the assembly for panel mount installations. 1. Install the wiring according to the electrical schematics.
SECTION 4 RMA / WARRANTY Forney Corporation warrants this product to be free of defective material and workmanship. Forney will replace this equipment as long as it is being used for its intended use and is found to be defective upon receipt up to the expiration of the warranty period.
SECTION 5 SPARE PARTS When ordering spare parts, contact Forney’s Spares Department via any one of the following methods and furnish the following information. MAIL PHONE Attn: Spare Parts (972) 458-6100 or Forney Corporation (972) 458-6142 or (972) 458-6600 16479 North Dallas Parkway Suite 600...