  • Page 1 SALERNO PELLET Pellet stove Assembly and exploitation manual...
  • Page 2: Safe Distances

    The installation must be performed by a quali- fied expert in the field of heating installations or authorized by “FERROLI’’ service. The place and way of connecting the stove should be selected carefully in accord with the safety instructions. Install away from flammable objects! •...
  • Page 3 1. PURPOSE The stove is purposed to heat domestic and public premises by the means of pellets. The stove is equipped with a steel water jacket designed for heating systems with water temperature up to 90º C at a maximum super pressure up to 0,15 Mpa. Tests are run at pressure of 0,3 Mpa. The stove is designed and manufactured to work with A-class pellets only ( DIN plus 51731 ) with the following characteristics: •...
  • Page 4: Technical Data

    2. TECHNICAL DATA SALERNO PELLET Maximum / minimum power 12,00 / 3,90 18,00 / 6,00 24,00 / 7,50 30,00 / 14,00 Average consumption of pellets kg/h Efficiency (nominal / reduced) 95 / 95 94 / 95 94 / 95 93 / 93...
  • Page 5 The accumulating char reduces the temperature difference and the condensation. • “FERROLI” provides a warranty and out of warranty service and replacement of the water jackets. • The warranty is not valid in case of a stove with a swollen water jacket which is a result of pressure increase in the system and improper connecting.
  • Page 6 If possible, avoid adding horizontal sections. Direction shift is done by using knee joints with a max angle of 45˚. For heating devices equipped with a smoke ventilator, i.e all of the “Ferroli” stoves, the following instructions must be observed: •...
  • Page 7 4. Cleaning Cleaning the fireplace should be done only when cold. The cleaning of the combustion chamber must be carried out daily. For this purpose, make sure the fireplace has ceased operation and is completely cold. Pull up the combustion pot and remove it from the stove and then clean it from soot.
  • Page 8: Service Compartment

    Cleaning the pellet bunker Service compartment Ash container Once the client uses the manual cleaning mechanism the ash will drop to the ashtray in the combustion chamber as well as in the service chamber that is located beneath.
  • Page 9 1. DHW PUMP; 5. EXHAUST FAN; 2. PUMP COLD WATER; 6. POWER SUPPLY; 3. SAFETY VALVE; 7. AIR INTAKE PIPE; 4. HOT WATER; 8. KEY FOR CLEANING MECH- ANISM OF THE TURBULA- TORS...
  • Page 10: Maintenance Program

    The safety instructions described in this management are not met; Unforeseen risks: Pellet fireplace “FERROLI” has been designed and manufactured in accordance with the safety requirements on the national, regional and European levels. Although considered possible risks arising from improper use, you may experience the following risks: •...
  • Page 11 K400 TOUCH SCREEN DISPLAY 1. HOMEPAGE Date & Time Errors Code 11:24 Fri 14 Oct 2016 Er.01 21° Main Temperature IGNITION Functioning State 65° Main Thermostat ON/OFF Settings Display Info Chrono...
  • Page 12 Main Commands In order to go to Homepage 2 a horizontal swipe must be performed to the right side of the screen. 12:18 Fri 14 Oct 2016 Er.01 Igniter Auger Pump 1 Pump 2 Pump 3 Aux1 Aux1 Aux3 System activity LEDS The Quick visualization of the system main function is accessed through a vertical swipe to the top side of the screen.
  • Page 13: Error List

    Quick visualization of the system main function 2. ERROR LIST 12:18 Fri 14 Oct 2016 Blocking or non-blocking error Er.01 21° is highlighted with a and the related error code. When pressed the error window opens IGNITION 65° Error List By clicking on ( ) you can see the errors stored by date / time...
  • Page 14: Main Commands

    IGNITION Blocking / Removing Error 65° 4. MAIN COMMANDS 11:24 Ven 14 Ott 2016 Er.01 ON/OFF Menu 21° Screen image : Swipe to Ignite • System power ON • System power OFF IGNITION • Alarms reset 65° 11:24 Ven 14 Ott 2016 Er.01 Display Menu Display Menu...
  • Page 15 IGNITION 65° 5. CHRONO 12:18 Ven 14 Ott 2016 Er52 Chrono - Daily CHRONO 22° select desired CHRONO program, press on the respective tabs: • Daily • Weekly RECUPERO ACCENSIONE DAILY WEEKLY WEEKEND • Weekend. 28° To change the chrono program, press on .
  • Page 16 5. INTERNAL MENU STRUCTURE From the display Menu the user can access the panel settings and select one of 24 languages Brightness. Minimum brightness: this function allows you to choose the minimum brightness level which the device automatically sets to after 30 sec. of inactivity. Standby display: if enabled, this function will set the screen to standby after 1 minute of inactivity.
  • Page 17 CONTROL PANEL: USE AND FUNCTIONS The main frame shows: time and date, chrono activation, combustion Chrono Active Date and Time State power and recipe, functioning state, error code, MESSAGES main temperature, main thermostat, Comb. Power Error Code summer/winter mode. Description Code Sond Anomaly of the probes checking, during Check Up phase.
  • Page 18 FAN ENCODER SIGNAL KEY FOR CLEANING MECHANISM VOUT N.O. RELAY FOR THE CLEANING MECHANISM AUGER POWER CABLE COMBUSTION PROGRAMMER SAFETY PUMP 1 IGNITER WATER VOUT PRESSURE SENSOR PRESSURE SWITCH BUFFER PROBE BOILER PROBE 31 GND MOTOR FOR 20 - înapoi CLEANING 29 GND N.C.