11 Factory Reset the Power Genius XL
The configuration of the Power Genius XL can be reset to the "factory defaults" using the following procedure:
•
Turn the amp off using the power switch on the back panel.
•
Press and hold STBY/OPER front panel button
Turn ON the amplifier.
•
When you see a blue circle on the front-panel display, release the STBY/OPER button.
•
•
Tap the blue circle with your finger. Another blue circle will be displayed at a different position on the
display - tap it. Continue tapping the blue circles until the self-test results are shown on the front panel
display.
•
Start the Power Genius XL Utility. You should now be able to connect to the amp.
Set all configuration options as desired and then click SAVE. If you do not click SAVE, the new settings
•
will not be retained, and you will have to rerun the reset procedure.
12 Alarms
If the amplifier detects an operational error, a message is displayed on the main display, as shown below:
The alarms and their meanings are shown in the following list:
Alarm Message
HIGH SWR
WRONG BAND
CB NOT ALLOWED
PLEASE UNKEY
When an alarm is raised, the amplifier disengages to protect itself from damage. The alarm is cleared when the
PTT is released.
Copyright 2020 FlexRadio. All Rights Reserved.
High SWR has been detected on the output port.
Band data not detected. Check your band data
settings/connections/sources.
The amplifier is set to a band it cannot use.
The amplifier needs to make a change that can only be done when
it is unkeyed.
Page 57 of 61
Description
August 27, 2020 (FW:3.4.16 Utility:2.2.10)
Need help?
Do you have a question about the Power Genius XL and is the answer not in the manual?