Autocall 4100ES Manual

Autocall 4100ES Manual

Fire control panels

Advertisement

UL, ULC Listed*
Features
Compatible with 4120 Network.
NDU provides annunciation for up to 12,000 network points:
• The basic Network Display Unit (NDU) is a special purpose master
controller for 4120 networks that includes a 4120 modular network
interface card
• Combining a basic NDU with a Voice Command Center (VCC) provides
an additional separate Network node within the same cabinet for
control of Network level Emergency Voice/Alarm Communications
Equipment
Master Controller (top) bay:
• Master controller assembly with operator interface
• Enhanced CPU with dual configuration programs, convenient service
port access, and capacity for up to 12,000 points
• System power supply (SPS) and charger (9 A total) with on-board
programmable auxiliary output
• Operator interface that is conveniently color coded with raised
switches providing high confidence feedback
• Available with InfoAlarm Command Center expanded content user
interface (refer to data sheet AC4100-0045 )
• Construction that is optimized for easy installation, upgrade, and
maintenance
• Glass door (ordered separately) provides view of available operator
controls visible behind locked door
Standard addressable interfaces include:
• Remote annunciator module support via RUI (remote unit interface)
communications port
NDU field installed option modules include:
• DACT and City Connection
• Service modems for remote panel status inquiry
• RS-232 ports for printers or maintenance terminals
• Alarm relays and expansion power supplies
• SafeLINC Internet Interface
• Battery brackets for seismic area protection
For NDU with VCC:
• Optional features are similar to a networked fire alarm control panel
and an extensive list of modules are available for; initiating, notification,
and user interface
Listed to:
• UL 864, Fire Detection and Control (UOJZ), Smoke Control Service
(UUKL), Releasing Device Service (SYZV)
• UL 1076, Proprietary Alarm Units - Burglar (APOU)
• UL 2017, Process Management Equipment (QVAX), Emergency Alarm
System Control Units (FSZI)
• UL 1730, Smoke Detector Monitor (UULH)
• UL 2572, Mass Notification Systems (PGWM)
• CAN/ULC-S527 Control Units for Fire Alarm Systems (UOJZ7), Releasing
Device Service (SYZV7)
• ULC/ORD-C1076 Proprietary Burglar Alarm Units and Systems (APOU7)
• ULC/ORD-C100 Smoke Control System Equipment (UUKL7)
* Additional listings may be applicable; contact your local Autocall product supplier for the latest status.
4100ES Network Display Units with SPS Power Supplies for 4120 Network
Introduction
The 4100ES Network Display Unit
The 4100ES Network Display Unit is a 4120 network level annunciator
and manual system/point controller. It provides alphanumeric
annunciation for up to 12,000 Network points and/or point lists and
can be programmed to function as the network master controller for
Alarm Silence, Trouble Acknowledge, and System Reset. is a network
level annunciator and manual system/point controller. It provides
alphanumeric annunciation for up to 12,000 Network points and/or
point lists and can be programmed to function as the network master
controller for Alarm Silence, Trouble Acknowledge, and System Reset.
4100ES Fire Control Panels
Figure 1: Network One-Line
Diagram Showing an NDU with VCC
AC4100-0036 Rev. 19 3/2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4100ES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Autocall 4100ES

  • Page 1 Alarm Silence, Trouble Acknowledge, and System Reset. * Additional listings may be applicable; contact your local Autocall product supplier for the latest status. AC4100-0036 Rev. 19 3/2018...
  • Page 2 4100ES NDU (as well as other network control panels) of point The Battery Compartment (bottom) accepts two batteries, up to 50 status and panel condition. This allows system information to reach Ah, to be mounted within the cabinet without interfering with module the proper location for appropriate system response.
  • Page 3: Packaging Availability

    4100ES Network Display Units with SPS Power Supplies for 4120 Network Packaging Availability master controller includes analog values for: battery voltage, charger voltage and current, actual system voltage and current, and individual • Modules are power-limited (unless specifically noted otherwise) NAC currents •...
  • Page 4 4100ES Network Display Units with SPS Power Supplies for 4120 Network Media Cards for 4120 Modular Network Interface Cards For additional information on 4120 fire alarm products and specifications, refer to data sheet AC4100-0056 Table 1: Media cards for 4120 Modular Network Interface Cards...
  • Page 5: Operator Interface

    4100ES Network Display Units with SPS Power Supplies for 4120 Network Size Definitions • Block = 4" W x 5" H (102 mm x 127 mm) card area • Slot = 2" W x 8" H (51 mm x 203 mm) motherboard with daughter card Operator Interface Convenient Status Information.
  • Page 6: Operator Interface Features

    4100ES Network Display Units with SPS Power Supplies for 4120 Network Operator Interface Features • Convenient and extensive operator information is provided using a logical, menu-driven display • Multiple automatic and manual diagnostics for maintenance reduction • Alarm and Trouble History Logs (up to 1250 entries for each, 2500 total events) are available for viewing from the LCD, or capable of being printed to a connected printer, or downloaded to a service computer •...
  • Page 7 Description Supv. Alarm 4100ES NDU with VCC includes the first bay equipment described for the NDU (above) and a second bay assembly with separate: Network Interface Module (select media cards separately); Standard Master Controller CPU with RUI output communications A100-9142...
  • Page 8 Requires 2 Slots (4" [102 mm]), locate on expansion bay only; space behind for A100-1243 audio system; mounts on front panel 4100ES flat modules only Supv. current = 2.4 mA; Active current = 6 mA A100-1252 1 Channel (audio or mike) Single slot modules requiring connection to an LED/switch controller;...
  • Page 9 4100ES Network Display Units with SPS Power Supplies for 4120 Network Table 11: Options for use with either Analog or Digital Amplifiers* Description Description Flex-35/50 NAC Expansion Module; (Adds 3 Class B, 1.5 100 W Amplifier NAC Expansion Module; (Adds six Class B, 2 A...
  • Page 10 4100ES Network Display Units with SPS Power Supplies for 4120 Network Voltage/Listing Description Size Supv. Alarm Additional System Power Supply (SPS); 9 A power supply/charger ; three 3 A Class A/B NACs, one programmable Aux Relay and one 2 A...
  • Page 11 4100ES Network Display Units with SPS Power Supplies for 4120 Network NDU or NDU with VCC Additional Options Table 17: NDU or NDU with VCC Additional Options Description A100-1279 Single blank 2" display cover; order as required (8 fill a bay front); two max. in a row between LED/switch modules...
  • Page 12: Wall Mounted Enclosure Installation Reference

    4100ES Network Display Units with SPS Power Supplies for 4120 Network Wall Mounted Enclosure Installation Reference Figure 3: Enclosure Install Reference Note: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedi- cated Earth connection per NFPA 70, Article 250, and NFPA 780.
  • Page 13: General Specifications

    4100ES Network Display Units with SPS Power Supplies for 4120 Network General Specifications Table 19: NDU General Specifications Specification Rating 120 VAC Models 4 A maximum @ 102 to 132 VAC, 60 Hz Input Power [System (SPS); Expansion (XPS); Remote 2 A maximum @ 204 to 264 VAC, 50/60 Hz;...
  • Page 14 © 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall product supplier for the latest status. Listings and approvals under Tyco Fire & Security GmbH, and the product names listed in this material are marks and/or registered marks.

Table of Contents

Save PDF