2.4 PERFORMANCE

MAXIMUM LOAD:
SPEED REGULATION:
SPEED ACCURACY:
Analog Mode:
Linearity:
Digital Mode:
DISPLACEMENT POWER FACTOR:

2.5 CUSTOMER ADJUSTMENTS

ACCELERATION TIME:
DECELERATION TIME:
MAXIMUM SPEED:
JOG SPEED:
CURRENT LIMIT:
GAIN RANGE:
STABILITY:
MINIMUM SPEED:
JUMPERS: JP1
JP2

2.6 INDICATORS

Current Controller board
HS1, HS2, HS3 (encoder)
Low level POWER
OVervoltage/UNdervoltage
Power Loss
Instantaneous Over Current
BUS (charging/ready)
ENABLE

2.7 TERMINAL DESCRIPTIONS

TB1
Current Controller Board (Part # 4001-141108-XXX)
1
Shields and Ground connection
2
HS1 position encoder
3
HS3 position encoder
4
HS2 position encoder
5
HS4 speed encoder
6
HS5 speed encoder
7
Common for encoder ONLY
8
+5VDC for encoder ONLY
9
Common for terminals 10 and 11
10
Auto/Manual Selection +24VDC
11
External Frequency Input +24VDC
12
Collector of FAULT transistor
13
Emitter of FAULT transistor
14
Load output (-2VDC = 150%)
15
Auxiliary Supply output
16
Power Common
TB2
Speed Controller Board (Part # 4001-141107-XXX)
1
RUN contact
(closes on RUN)
2
RUN contact
1 Amp 125VAC
3
-24VDC raw supply 50mA max
4
RUN input +24VDC to RUN
5
RUN hold (junction of RUN and STOP)
6
SPARE (tie point for motor thermal)
10
Page
150% for 1 minute out of 10 minutes
0% (no load to full load)
(percentages referred to set speed over 100:1 speed range)
+/- 1.0% (typical with speed pot supplied by internal reference)
+/- 0.5% (typical from external reference source)
0% (+/- 3/4 revolution of motor shaft)
0.96
2 to 30 seconds, linear, analog mode
2 to 30 seconds, linear, analog mode
600 to 5000 RPM, motor dependent
0 to 30% of maximum speed, analog mode only
0 to 150%, resistor calibrated
10 to 1
20 to 1 dynamic range
0 to 15% (with 5K speed pot)
IN: ramp to stop OUT: coast to stop
IN: standard accel and decel
Speed Controller board
RUN
Current Limit
Zero Speed
Base Driver board
Base Drivers (6)
17
TB3
OUT: 50 msec accel and decel
Current Sensor board
UnderVoltage
Undervoltage Time Out
OverVoltage
Heatsink OverTemperature
THerMaL
RELAY ON
7
Emergency STOP +24VDC to RUN
8
+24VDC RUN Logic Supply 50mA max
9
+10VDC reference supply
10
Speed reference input 0 to +10VDC
11
Minimum speed connection for speed pot
12
Signal common
13
Jog input +24VDC to JOG
14
Forward/Reverse input +24VDC to reverse
15
Frequency output open collector to common
16
Zero speed output open collector to common
+24VDC raw supply 50mA max
18
Current reference 0 to +10VDC (velocity error)
Current Sensor Board (Part # 4001-144009-XXX)
1
Trip calibration resistor
2
Trip calibration resistor
3
RTO output
4
Horsepower calibration resistor
5
Horsepower calibration resistor
6
Motor Thermal input
7
Motor Load output (-10VDC = 180%)
8
Common
9
-24VDC
10
Contactor control
Model 2000C / 3000C Manual