V02/20 Installation and Operating Instructions Electrostatic charging system iONcharge 20 kV Translation of the original operating instructions...
Page 2
To the best of our knowledge and belief, the information contained in this publication was correct and valid on the date of publication. Gema Switzerland GmbH makes no representations or warranties with respect to the contents or use of this publication, and reserves the right to revise this publication and make changes to its content without prior notice.
Overview of local multi-function LED: Functions ..........29 Description of LED functions ................. 29 Network Operation ....................31 Application information Basic layouts for charging applications ..............34 Example: Attaching to wrap ..............34 Table of contents • 3 iONcharge 4.0...
A single charging applicator or a combination of positive negative applicators can be used for “pinning” or “tacking” together sheets and webs of film or paper. Introduction • 5 iONcharge 4.0...
The ATEX certified version of the iONcharge-4.0 system guarantees the highest safety levels for usage in potentially explosive environments – refer to version table. 6 • Introduction iONcharge 4.0...
Control of compound solutions via Can-Bus and iONcontrol Touch Panel – The emitter pins are decoupled from the high voltage using resistors – All electrical connections are fail safe, vibration-proof plugs in housing protection type IP 54. Introduction • 7 iONcharge 4.0...
Any use not described this manual as well as changes to the hardware are not permitted. ► Only original spare parts delivered by Gema Switzerland GmbH may be used for maintenance and repair of the systems! Installation and commissioning of the system need to fulfill all local safety standards and instructions for safe use.
V02/20 Safety symbols (pictograms) The following contains a list of warnings with their meanings found in the Gema operating instructions. Apart from the regulations in the relevant operating instructions, the general safety precautions must also be followed . DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Technology. An application engineer is available to assist in the assessment of whether the use of electrostatic charging equipment is suitable. High voltage operation (green LED lights up permanently) should only be active when it is required for the application. Safety Instructions • 11 iONcharge 4.0...
WARNING Danger of electric shock ► Keep charging bars wired to ground at all times while the system is operational regardless of whether the 24 VDC power supply is operational or not. 12 • Safety Instructions iONcharge 4.0...
It is not possible to specify a common figure of the ozone concentration during usage. – If the ozone concentration becomes an issue at a specific workstation, on-site measurement has to be taken and adequate ventilation must be provided. Safety Instructions • 13 iONcharge 4.0...
► All installation and repair work must be performed by qualified technicians! Authorized and trained personal ► Assembly, commissioning and maintenance of the iONcharge system may only be performed by trained and qualified personnel User Duties • 15 iONcharge 4.0...
Page 16
► If the iONcharge system needs to be removed from the point of use, switch off the power supply. ► If the power plug needs to be removed, ensure safe grounding of the system on the ground terminal next to the bus system. 16 • User Duties iONcharge 4.0...
– Accessories – Correct manual In case of incorrect deliveries or questions, please contact your local representative or Gema Switzerland GmbH. Follow local instructions for package material disposal. User and working safety prior to commissioning WARNING Danger of electric shock ►...
Damage to components Use a brass brush for cleaning in order to avoid damage and scratches. ► This should preferably have a curved handle in order to avoid injuries to the hand from the emitter pins. 18 • User Duties iONcharge 4.0...
Ensure that there is no ground nearby pins beside the ground needed for the charging application. Mounting bars and parts must be behind the electrode and minimum 2 x the distance from pin to substrate as shown in Fig. 2. fig. 2 Mechanical Installation • 19 iONcharge 4.0...
V02/20 Avoiding loss of efficiency ATTENTION Ground near emission pins ► Ensure that there is no ground near the pins. > 2xd > 2xd fig. 3: 20 • Mechanical Installation iONcharge 4.0...
Slide on clip M5 screw in T-slot fig. 4: Grub screw for position Screw set is part of delivery fixation (hexagon head screw DIN 4017 M5x25; plain washer DIN 125 M5; screw nut DIN 4032 M5) Mechanical Installation • 21 iONcharge 4.0...
Mounting option 1 at least 2 attachment screws per m + 1 Pro per additional m Mounting option 2 Freely slidable GRP brackets (at least 2 per m + 1 Pro per additional m) GL working width Dimensions • 23 iONcharge 4.0...
V02/20 Electrical Connection Connector specification Bus system connector, M12, 5-pin, easy and flexible adaptation for individual systems via "daisy chain" connection. fig. 6: Standard version fig. 7: 90 degree version: Option Electrical Connection • 25 iONcharge 4.0...
(20 kV < 500 mA) Pin 3 CAN High Pin 4 CAN low Pin 5 WARNING Danger of electric shock ► Always ground using the ground stud! fig. 9: Connection to machine or plant mass / ground 26 • Electrical Connection iONcharge 4.0...
= 24 VDC OFF Factory settings HV frequency range to 100 Hz max. output voltage 20 kV Operating mode AUTO Clean Bar Warning at 40% efficiency loss Clean Bar Alarm at 60% efficiency loss Electrical Connection • 27 iONcharge 4.0...
In order to use the error output, PIN 1 must be connected via a 680-Ohm resistor to the 24 V power supply. R = 680 Ohm / 2 W 24 V = System OK 0 V = System fault 28 • Electrical Connection iONcharge 4.0...
(contamination) System efficiency has dropped from originally 100 % to 60 %. This mode shows that the contamination of the bar has reached the ALARM set alarm value. (Factory setting = 60 %) (contamination) Electrical Connection • 29 iONcharge 4.0...
Page 30
CAN "hard-beat". If there is no BUS available, the system automatically switches to the initialization state and activates the charge. This mode shows that the charge electrode has been installed to close Check Installation to a ground / machine ground. 30 • Electrical Connection iONcharge 4.0...
T-connector to T-connector. – See network layout drawings. 5 m maximum. For detailed information on the wiring of the individual options, please refer to the drawings attached to this manual. Electrical Connection • 31 iONcharge 4.0...
V02/20 Application information With the iONcharge 4.0 charging system, it is possible to automate and control a wide range of industrial processes through targeted charging. This includes fully automatic roll changes without gluing, blocking and adhesion of materials, improvement of print quality, targeted application of aerosols and coatings, fixation of web materials and much more.
Example: Cooling roll adhesion The charging bar is located opposite the grounded cooling roller. As a result of the electric field, the material band will stick to the grounded roller. 34 • Application information iONcharge 4.0...
Open collector (OR-circuit) max. 28 V 100 mA General Value Min. Nom. Unit Communication CAN Open Bus clock kbit/s Termination (external and on both sides) Ω term. Ground connection terminal with M5 screw and nuts at machine ground Technical Data • 37 iONcharge 4.0...
PIN AGED flickering red 50/50 ms active TIMEOUT triple flash red active FAILURE constant Red active UNCONFIGURATED blinking Red 200/200 ms active STARTUP blinking green 200/200 ms Check Installation flickering red yellow 50/50 ms active 38 • Technical Data iONcharge 4.0...