Summary of Contents for heatapp! T2B

  • Page 1 Instruction manual heatapp! system experience heating new 0450000542-1927 Instruction manual heatapp! system English...
  • Page 2: Table Of Contents

    5.2.3 Requirement request to the energy generator ................... 18 5.2.4 Electrical connection heatapp! base ......................19 5.2.5 Connecting heatapp! base T2B ........................20 5.2.6 Update heatapp! base und heatapp! gateway.................... 22 5.2.7 Update installation via USB Stick ........................ 22 S. 2...
  • Page 3 Safety 5.2.8 Initial operation / initial configuration ......................23 heatapp! gateway ................................26 5.3.1 Setting up ..............................26 5.3.2 Connectiat heatapp! gateway........................26 5.3.3 Initial operation / initial configuration ......................27 heatapp! radio components ............................29 Including radio components ............................29 Excluding of radio components ............................
  • Page 4 Safety 11.2.9 Reset to factory settings ..........................74 11.2.10 Removal ..............................75 11.3 heatapp! sense ................................76 11.3.1 Montage heatapp! sense ..........................76 11.3.2 Insert / change battery ..........................76 11.3.3 Including / Excluding at heatapp! gateway ....................77 11.3.4 heatapp! sense connection test .........................
  • Page 5 Safety 11.7.9 Functions of the learn key heatapp! repeater S ..................90 11.8 Window sensor ................................91 11.8.1 Window contact as information ......................... 91 11.8.2 Window shutdown setting ......................... 91 Z-Wave wireless network ............................... 93 12.1 Notes for radio coverage ..............................93 Radio coverage ................................
  • Page 6 Technische Daten................................119 18.1 heatapp! base ................................119 18.2 heatapp! base T2B ................................. 120 18.3 Drilling template heatapp! base / heatapp! base T2B ....................121 18.4 heatapp! gateway ................................. 122 18.5 heatapp! drive ................................123 18.6 heatapp! floor ................................124 18.7...
  • Page 7: Safety

    Safety Safety General information The devices are not suitable for children and must not be used as toys. Store packaging material safely away from children or dispose of it. Do not dismantle the devices; they do not contain any user-serviceable parts. If defects occur, please contact your installer. Structure of the warning instructions Explanation of the warning instructions in this manual: Danger...
  • Page 8: Intended Use

    Safety Intended use The device or system is intended solely for the use described in the section "System description", with supplied and approved components. Any other use is classified as an improper use. The manufacturer shall not be liable for any damage resulting from this. The user/operator is solely responsible for the risk.
  • Page 9: System Description

     heatapp! as remote control when connecting the system to the energy generator via OpenTherm bus or T2B bus for THETA controllers. In order to control this setting, the outside temperature is used to determine the heat demand. The available heating circuits (without room station) are displayed as room groups.
  • Page 10: The Z-Wave Wireless System

    System description temperature determined in each room. When the setpoint temperature is reached, the heat request to the energy provider is stopped, so that it can be turned off. In order to determine the actual temperature, the heatapp! radio components and the heatapp! gateway are required.
  • Page 11: Heatapp! Components

    Starting with version V3.X, heatapp! base T2B is the central control unit in conjunction with the THETA controller. The heatapp! base T2B can communicate with the energy generator via the switching contact, 0 - 10 V and T2B bus interfaces of an existing heating system and transmit the heat demand to the THETA controller.
  • Page 12: Heatapp! Single Floor

    heatapp! Components heatapp! single floor The heatapp! system operates a Z-wave component available on the open market, to be able to execute heating-relevant functions. Only those components which we declare as having been heatapp! checked can be assigned a room in heatapp! and consequently adopt a heating-relevant function.
  • Page 13: Heatapp! App

    All data, accesses and passwords are saved at home in your heatapp! base / base T2B and are only accessible to authorised users after login.
  • Page 14: Technical Requirements

    Technical Requirements Technical Requirements You can use the heatapp! system with your underfloor or radiator heating as well as with electric heaters, irrespective of what sort of heat source you have. To be able to operate heatapp! conveniently from anywhere, you require: •...
  • Page 15: Heatapp! And Internet

    Technical Requirements heatapp! and Internet An Internet connection is required to be able to operate the heatapp! system from anywhere. A wired connection to the Internet is available in most homes (ADSL, cable, optical fibre). Fig.: 3 DSL or UMTS heatapp! can be operated via mobile Internet (SIM card).
  • Page 16: Installation And Initial Operation

    Installation and initial operation Installation and initial operation Note By single room control please adhere to the specified sequence for installation and initial operation of the heatapp! base and heatapp! gateway. 1. Firstly, completely configure heatapp! base, 2. then configure heatapp! gateway. heatapp! radio components For initial operation of a heatapp! system a standard laptop and the heatapp! installation kit comprising the heatapp! USB-LAN adapter and a network cable are required.
  • Page 17: Heatapp! Base

    Installation and initial operation heatapp! base 5.2.1 Opening the housing Fig.: 4 Opening the housing, heatapp! base Push the terminal cover up to the stop approximately 1 cm downwards. Press the latch of the terminal cover carefully apart using a screwdriver. To prevent damage to the electronics, do no push the screwdriver in too far when doing so.
  • Page 18: Requirement Request To The Energy Generator

    Connect the T2B link cable to the terminals T2B BUS (in doing so, ensure correct polarity A / B!). Subsequently, use the the set-up wizard and select the option “Regulator T2B” in the “Energy generator” field.
  • Page 19: Electrical Connection Heatapp! Base

    Installation and initial operation WARNiNG Danger due to live parts. Some components are electrically live. Contact with live parts can result in an electric shock, burns or even death. Before working on the electrical system, observe the following points: • Switch the system to a zero volts state.
  • Page 20: Connecting Heatapp! Base T2B

    VDE 0100 or the corresponding national regulations must be observed. Replace the terminal cover. werden. The heatapp! Wi-Fi stick is not included in the standard scope of delivery; it must be ordered as an accessory. 5.2.5 Connecting heatapp! base T2B Fig.: 7 Connection variant at WG 500 S. 20...
  • Page 21 Installation and initial operation Fig.: 8 Connection variant wall base MS-K Fig.: 9 Connection variant THETA S. 21...
  • Page 22: Update Heatapp! Base Und Heatapp! Gateway

    Installation and initial operation 5.2.6 Update heatapp! base und heatapp! gateway Provided heatapp! base and heatapp! gateway are connected to the Internet and the installation takes place via PC/laptop/smartphone or tablet, the system requests the installation of a possibly available update. Alternatively, from version 2.1xxx, updates can be installed via USB stick, if an Internet connection is not available or not wanted.
  • Page 23: Initial Operation / Initial Configuration

    Installation and initial operation 5.2.8 Initial operation / initial configuration Fig.: 10 Initial set-up heatapp! base heatapp! USB-LAN Adapter or heatapp! Installations-Stick Note When updating the device software by downloading via the Internet additional costs may be charged depending on the customer's actual Internet tariff.
  • Page 24 OT interface open to external connections. E.g. an OT room station can be replaced by the heatapp! base. • Regulator T2B The T2B bus (THETA 2 wire bus) enables heatapp! to set the hot water and flow temperature for all heating circuits without a room station. •...
  • Page 25 Selection of single room control When connecting the heatapp! base T2B to the regulator or the heatapp! base to the Open Therm Bus, you must select whether the system is used with single room control or as remote control for the controller.
  • Page 26: Heatapp! Gateway

    Installation and initial operation heatapp! gateway 5.3.1 Setting up The heatapp! gateway is designed to be set up as a table-top unit. Find a suitable installation location for the heatapp! gateway that fulfils the following requirements: • A 230 V outlet must be available at the installation location of the heatapp! gateway. •...
  • Page 27: Initial Operation / Initial Configuration

    Installation and initial operation Moreover, inform the customer that future changes to their Wi-Fi network (new router, changed password, etc.) can impair the operation of heatapp! and many require an adjustment to the heatapp! set-up. Connect the supplied plug power supply unit to the heatapp! gateway.. Plug the power supply unit into a power outlet.
  • Page 28 Installation and initial operation The last 6 digits of the Mac address of heatapp! gateway (located on the nameplate) are shown in brackets. Connect your laptop, tablet or smartphone via WLAN to the heatapp! gateway network. Shortly thereafter, the set-up assistant starts automatically in the browser window of your laptop. If the set-up assistant does not start automatically, enter the address http://10.0.0.1 in the address line of the browser.
  • Page 29: Heatapp! Radio Components

    heatapp! radio components heatapp! radio components The heatapp! gateway must be fully set up and the LED on the side must be a steady GREEN. Please refer to section "LED on heatapp! gateway", on page 116 to determine the meaning of other conditions and for troubleshooting instructions. Include the radio components close to the heatapp! gateway.
  • Page 30: Connection Test And Repair Radio System

    Connection test and Repair radio system Connection test and Repair radio system The heatapp! gateway communicates with all radio components via Z-Wave wireless. In the Z-wave wireless standard, a meshed network is created within a few days. The functions “Connection test” and “Repair radio system” are provided for checking and repairing the radio network.
  • Page 31: Completion Of The Set-Up

    Completion of the set-up Completion of the set-up After the set-up is complete, create an establishment protocol and a backup. If you want to set up a single room control, create the establishment protocol and the backup only after the complete installation of the heatapp! gateway. Establishment protocol The establishment protocol (look also selection „Establishment protocol“) can be found in the heatapp! base menu.
  • Page 32: Heatapp! App

    heatapp! App heatapp! App The app is the user interface of the heatapp! system. Next, all individual areas of the App are explained in more detail. At home, the app accesses the heatapp! system via the Wi-Fi connection of a tablet or smartphone. For this to occur, the heatapp! system must be connected to the router and the Wi-Fi connection on the tablet or smartphone correctly configured.
  • Page 33: Control

    Control Control Depending on the size and type of the operating device, operation can vary slightly. Therefore this guide is only representative. 10.1 Starting App and Login to a system Fig.: 14 Homescreen Demo-Mode Demo mode is available on the left side of the start screen. In demo mode you can discover for yourself what options heatapp! offers.
  • Page 34 Control Note For the first login to your heatapp! system, your operating device (tablet or smartphone) must be connected to the same network as your heatapp! system. The heating systems are listed by name. Directly under the name it is apparent whether the heating system is in the same network "local network" or the connection to the heating system is made via the "Internet"...
  • Page 35: User Roles And Access Rights

    Control Fig.: 16 Entry of the IP adress Tippen Sie auf die Schaltfläche (1) „Suchen“. Geben Sie im Dialogfeld die IP-Adresse (3) der heatapp! base ein. Bestätigen Sie die Eingabe indem Sie auf die Schaltfläche (4) „Anmelden“ tippen. Über die Schaltfläche (2) „Zurück“ gelangen Sie wieder zum StartMenu ohne sich anzumelden.
  • Page 36: The Homescreen

    Control • An "Expert" cannot see or create profile or room images saved in the system; a neutral place holder is shown in each case. • A "User" can see the room images saved in the system by the "Owner". A "User" can create and edit their own profile image.
  • Page 37 Control Fig.: 18 Update available Pressing the "now” button takes you to the update page of heatapp! gateway or heatapp! base. With the "later” button, you are reminded again of the available update in 5 days. Note If you have not yet visited the heatapp! gateway menu via your operating device, you must enter the gateway password. Exiting the homescreen Tap the icon to return to the start screen.
  • Page 38 Control Room selection Rooms are displayed with their room images in the room selection. Vertical swiping scrolls through the rooms in a group. Horizontal swiping scrolls through the room groups. Rooms are selected by tapping. The selected room is highlighted with a red-orange border. Small icons in the room images display the current temperature and the currently active operation mode.
  • Page 39: Use Of Scenes

    Control The set temperature is displayed below the rotary control. This desired temperature is indicated in the room image using the magic wand. It applies until the timer program end, as a minimum, however, for the time set in expert mode. If the current room temperature corresponds to the set temperature, the halo disappears.
  • Page 40 Control In contrast to other scenes, here a long touch does not set the runtime of the scene, rather the start time of the scene in steps of 15 minutes. The duration of the scene is fixed at 1 hour. If the shower scene is activated, then the DHW cylinder is heated to the set target temperature from the start time.
  • Page 41: The "Settings" Menu

    The active holiday rooms can no longer be controlled using the thermostat rotary control. DHW heating is deactivated for the scene runtime (only with DHW connection via the bus system Open Therm, T2B). However a set Legionella protection scheme remains active.
  • Page 42 Control 10.2.2.1 Edit user profile Fig.: 19 „My profile" area In the "My profile" area you can edit the profile of the currently logged in user. Change profile image Via button (1) you can allocate a profile image from the gallery or taken using the mobile device camera to the user. Change password Tap the "Change password"...
  • Page 43 Control In the "Design" area you can edit the app design and audio settings. Change background image Tap the "Background image" button to change the app's background image. You can select a background image from the gallery or create one directly via the mobile device's camera (device dependent). Alternatively you can also select one of the four supplied heatapp! standard background images.
  • Page 44 Control Symbol Status Room in operation, everything OK. Room undefined, no radio modules assigned. Fault of a radio module in the room (e.g. room sensor battery discharged). Editing rooms Fig.: 22 Editing rooms Room immage Riin bane (name displayed) Standard name (specified during implementing) Raum group User list This is where you can change room names, assign a room image to the room and assign the room to certain users.
  • Page 45 Control Changing the room name To rename a room, tap on the room name and enter the desired name. In doing so only the displayed room name is changed. This change does not affect the standard name specified in the heatapp! base setup wizard. The standard name can only be changed in heatapp! base Expert mode (Settings / System / Expert) or by running through the setup wizard again.
  • Page 46 Control • To move a room group tap on the "Move room group" symbol and drag the room group to the desired position in the list. Tap on "Save and close" to accept the settings. You can now move the rooms by dragging and dropping between the room groups. 10.2.2.4 Managing users Fig.: 24 „Users“...
  • Page 47 Control Creating users Fig.: 25 Creating users Personal data Profile image User role Room list In the "Users" area tap on the "Create user" symbol. The pop-up window "Create user" is displayed. Select the user role for the new user. Enter the personal data in the input fields and select a user name and password.
  • Page 48 Control Editing user data, deleting users Fig.: 26 Edit user Button „Change password“ Button „Delete user“ Editing a user is analogous to creating a user. However there are two additional buttons to change the password and delete the user. Tap on a user in the area "Users". The pop-up window "Edit user" is displayed. Perform the required changes.
  • Page 49 Control Note The app must be separately downloaded on to every mobile device (smartphone / tablet) from the Apple AppStore or Google Play Store. The invitation links the app with the system. The user must be separately informed of their access data. 10.2.2.5 Managing devices Fig.: 27 „Devices"...
  • Page 50 Control 10.2.2.6 Editing scenes Fig.: 28 „Scenes" area In the "Scenes" area, the rooms for which the scenes are to apply, are assigned to the scenes. Tap a scene to open a room assignment. Tap on the rooms that are to be assigned to the scene under consideration. Horizontal swiping changes between the room groups.
  • Page 51 Control 10.2.2.7 Editing cycle times Fig.: 29 „Cycle times“ area Comfort temperature setting Eco temperature setting Set-back temperature setting Cycle time „Comfort temperatur active“ Cycle time „Eco temperature active“ Copy room cycle times (day-based) Copy room cycle times (room-based) In the "Cycle times" area, the cycle times for the comfort, eco and setback temperatures can be set separately for each room. A maximum of three cycle times can be created per day.
  • Page 52 Control The timer programs for domestic hot water are reached by horizontal swiping. A maximum of three timer programs can be created per day. In the intervals between the timer programs, the system regulates the hot water temperature to the set-back temperature.
  • Page 53 Control 10.2.2.8 Live View Fig.: 31 „Live View" area The statistics of the setpoints and actual values of the last 12 hours are displaced in Live View. A long-term statistic can be displayed via the monitor. See also chapter „Monitor“ If the energy generator is connected via OpenTherm or THETA controller, then provided they are available, the domestic hot water heating and the energy generator are also displayed.
  • Page 54 Control Fig.: 33 „Live View" energy generator area The "Live View" area displays the variation with time of the target and current temperatures for the selected rooms, domestic hot water and the energy generator. Horizontal swiping changes between rooms, hot water generation and energy generator. For changing rooms tap on the bottom right symbol..
  • Page 55: The „System" Menu

    Control 10.2.3 The „System“ menu Fig.: 34 „System" area In the "System" area you can access the complete menu of the heatapp! base. Note The menu of the heatapp! System can also be accessed via IP address on a PC or laptop in the local network. How to find out the IP address of your heatcon! System, refer to section "Network".
  • Page 56 Control 10.2.3.3 Establishment protocol In the "Establishment protocol" area an establishment protocol can be generated and sent by e-mail. The establishment protocol contains all the information about your heatapp! configuration. Generating the establishment protocol • A new report is created by tapping on the button "Generate a new establishment protocol". The establishment protocol is saved in the heatapp! base until a new establishment protocol is generated.
  • Page 57 Control 10.2.3.4 Network Fig.: 35 Network configuration The current network settings are displayed in the "Network" area. This is where you can change the network configuration, e.g. if for example a Wi-Fi is to be set-up after the initial configuration. You can also activate the connection to heatapp! connect from here.
  • Page 58 Control 10.2.3.5 Date / time Fig.: 36 "Date / time " area You can make the settings for the real-time clock in the "Date / time" area. For example, this is necessary, if the manual time setting was selected (summer / winter time). You can select between the following variants: •...
  • Page 59 Control 10.2.3.6 Notifications The heatapp! system sends push and e-mail messages in the event of faults or service notifications. Push messages are system notifications, which the heatapp! base sends directly to the user interface of the mobile device (smartphone / tablet), so that the user is immediately informed. These may be fault messages or service notifications. E-mail addresses that are to be used for the sending of automatic push messages can be saved under the "Notifications"...
  • Page 60: Expert Mode

     Room 1-24  Energy generator (by connection to the energy genertor only)  Regularo (only by connection THETA and heatapp! base T2B)  Fault messages  Configuration Information and modifiable parameters are available for each area. These differ depending on the connection to the energy generator.
  • Page 61: Monitor

    Control 10.2.5 Monitor The monitor shows current and historical data of your heating system. Fig.: 37 Monitorhome page 1 Zoom in / zoom out the X-axis 2 Selection day / week / month 3 Selection date (horizontal axis) 4 Representation of the individual areas 5 Menu Tap / click on the arrow (4) to open the display of the respective area.
  • Page 62 Control Selection options are available by tapping / clicking on the menu. Fig.: 39 Monitor menu 1 Zoom in / zoom out the Y-axis (vertical axis) 2 Selection of room / heating circuit / sensor and so on 3 Safe 4 Create screenshot (only possible on computer / laptop) The selected areas are highlighted in orange in the menu.
  • Page 63 Control The red vertical line moves by double-clicking / tapping on the desired time. This allows the comparison of the individual graphs. This makes it easy, for example, to find out where the request comes from. Fig.: 41 Monitor as analytical tool S.
  • Page 64: The „Gateway" Menu

    Control 10.2.6 The „Gateway“ menu Fig.: 42: „Gateway" area In the "Gateway" area you can access the complete menu of the heatapp! gateway. Note The heatapp! gateway menu is only available via the local network. The menu of the heatapp! gateway can also be called in the local network via an IP address on a PC or laptop. You can see how to determine the IP address of your heatapp! base in the “Network”...
  • Page 65 Control 10.2.6.2 Radio modules Fig.: 43: "Radio modules" area The radio modules of the heatapp! system are managed from the "Radio modules" menu. The menu is subdivided into three tabs: • Include and exclude: – By tapping on the "Include" button you can integrate further radio modules in to the system. After successful inclusion and registration, these are, dependent on the module, assigned to the desired room and you can assign a name (e.g.
  • Page 66 Control 10.2.6.3 Network Fig.: 44: Network configuration gateway S. 66...
  • Page 67 Control The current network settings are displayed in the "Network" area. This is where you can change the network configuration, e.g. if for example a Wi-Fi is to be set-up after the initial configuration. Tap button to return to the "Gateway" menu. 10.2.6.4 Setup wizard The "Setup wizard"...
  • Page 68 Control Reset to factory settings The "Reset now" button, resets the device to the factory settings. Note Upon resetting, all set data is irrevocably lost and a new setup is necessary. Please only use this option, if expressly requested to do so by our customer support or your expert. Resetting the heatapp! gateway requires resetting and re-registration of all radio components.
  • Page 69: Functions Of The Room- And Radio Components

    In the setup wizard, select the heatapp! base/T2B with the energy generator/single room heat regulation “off”, to activate the input E1 of the heatapp! base/T2B as the room sensor ((E1:EF for sensor input). Activate the heatapp! sense-wire for one of the available room groups.
  • Page 70: Heatapp! Drive

    Functions of the room- and radio components 11.2 heatapp! drive Fig.: 46: heatapp! drive Fig.: 47: Bedienung heatapp! drive "Enter" / "Lernkey" Setpoint temperature Lock Low battery Radio connection "Up" "Down" Alarm heatapp! drive is an electronic radiator thermostat for the heatapp! system for single room heat regulation of radiators in heating systems.
  • Page 71: Insert / Change Battery

    Functions of the room- and radio components 11.2.1 Insert / change battery Fig.: 48: Insert / change battery heatapp! drive Do not use rechargeable batteries. Unpack a heatapp! drive and insert the AA batteries in the battery compartment. Ensure you connect the positive and negative terminals correctly! Replace the battery cover.
  • Page 72: Mounting Heatapp! Drive

    Functions of the room- and radio components Now press the learn key (1) in the middle below the display. Check whether the heatapp! drive has been successfully registered on the heatapp! gateway. If no connection can be made, then if necessary a heatapp! repeater must be used to improve wireless coverage. 11.2.3 Mounting heatapp! drive Fig.: 50 Mounting heatapp! drive...
  • Page 73: Connection Test Heatapp! Drive

    Functions of the room- and radio components 11.2.5 Connection test heatapp! drive Fig.: 51: Connection test heatapp! drive Press the middle key for at least 3 seconds until "M" is output to the display. Then press the left key until "LI" is displayed and confirm with the central key. This approach triggers a device connection test.
  • Page 74: Window Open" Identification

    Functions of the room- and radio components 11.2.7 „Window open“ identification heatapp! drive has an integrated "Window open" detection facility. If the room temperature decreases quickly over a short period (e.g. during airing), the valve is closed to reduce heat losses. The valve remains closed for 30 minutes, then the heatapp! drive continues regulating according to its original settings.
  • Page 75: Removal

    Functions of the room- and radio components 11.2.10 Removal Fig.: 52: Removal heatapp! drive Keep the learn key depressed for 3 seconds to call the function menu. Repeatedly press "Down" until "M" appears in the display. Press the learn key to confirm the selection. "M"...
  • Page 76: Heatapp! Sense

    Functions of the room- and radio components 11.3 heatapp! sense Fig.: 53: heatapp! sense heatapp! sense is a battery operated temperature sensor for the heatapp! system for single room heat regulation of heating systems. The device is mounted on the wall in a room and wirelessly transmits the measured temperature to the heatapp! gateway. Wireless transmission takes place via the Z-wave protocol.
  • Page 77: Including / Excluding At Heatapp! Gateway

    Functions of the room- and radio components 11.3.3 Including / Excluding at heatapp! gateway Fig.: 55: Functions of the learn key In the menu of the heatapp! gateway select the menu item "Include and Exclude" under "Radio modules" and then "Include".
  • Page 78: Heatapp! Sense Control

    Functions of the room- and radio components 11.4 heatapp! sense control Fig.: 56: heatapp! sense control 11.4.1 Parameter structure Fig.: 57: Parameter structure heatapp! sense control S. 78...
  • Page 79: Heatapp! Sense Control Installation

    Functions of the room- and radio components Menu Parameter Info System Z-Wave Battery voltage Beep (Summer) Link Learnkey Display-modus = 1 Home ID_1 Include 1 Exclude 2 Learnkey 2 Home ID_2 Manufacturer-code Node Info Z-Wave Node ID (Device ID) Temperature-Offset Damp-Offset Reset 11.4.2...
  • Page 80: Excluding

    Functions of the room- and radio components After registration, attach the heatapp! sense control to the wall mounting plate. After registration, attach the heatapp! sense control to the wall mounting plate. Fig.: 59: Attaching the heatapp! sense control to the wall mounting plate and battery change To change the battery, carefully remove the heatapp! sense control from the wall plate using a screwdriver.
  • Page 81: Air Humidity Display

    Functions of the room- and radio components 11.4.8 Air humidity display If the Esc key is pressed once while the basic display is shown, the display of the actual temperature changes to an air humidity display. Repressing the Esc key returns the display to the basic display 11.4.9 Esc key During navigation through the menus, the Esc key acts as a back key.
  • Page 82: Heatapp! Floor

    Functions of the room- and radio components 11.5 heatapp! floor Fig.: 61: heatapp! floor heatapp! floor is a controller for thermal actuators in underfloor heating installations and is part of the heatapp! system, providing individual circuit control for underfloor heatings. Up to eight channels each with up to three thermal actuators can be controlled.
  • Page 83: Installation (Hat Rail Mounting) Of Heatapp! Floor

    Functions of the room- and radio components Fig.: 62: Installation heatapp! floor 11.5.1 Installation (hat rail mounting) of heatapp! floor Place the heatapp! floor on the top hat rail Engage the hooks by pressing down gently. 11.5.2 Antenna Ensure that subsequently the aerial can be installed outside the distribution box of the underfloor heating system.Schließen Sie die Antenne (4) mit dem Antennenstecker an den Antennenanschluss (5) am heatapp! floor an.
  • Page 84: Including / Excuding At Heatapp! Gateway

    Functions of the room- and radio components Connect the power supply to the heatapp! floor according to the terminal assignment. The operating indicator lights up in green when the heatapp! floor is ready for use. When connecting the power supply, VDE 0100 or the corresponding national regulations must be observed. 11.5.4 Including / excuding at heatapp! gateway In the menu of the heatapp! gateway select the menu item "Include and exclude"...
  • Page 85: Functions Of The Learn Key

    Functions of the room- and radio components 11.5.7 Functions of the learn key Fig.: 63: Functions of the learn key heatapp! floor S. 85...
  • Page 86: Heatapp! Single Floor For Electric Heaters

    Functions of the room- and radio components 11.6 heatapp! single floor for electric heaters Fig.: 64: heatapp! single floor These products are Z-Wave products sourced from the open market. The devices are heatapp! checked. They can be incorporated in all heatapp! systems in accordance with the installation manual. Please take all device-specific details from the manufacturer's instructions.
  • Page 87: Heatapp! Repeater And Heatapp! Repeater S

    Functions of the room- and radio components 11.7 heatapp! repeater and heatapp! repeater S Fig.: 65: heatapp! repeater und heatapp! repeater S heatapp! repeater and heatapp! repeater S are used to improved the wireless coverage in a heatapp! system. If one or more radio components cannot be reached, a repeater is used to enable/improve communication.
  • Page 88: Installation Heatapp! Repeater

    Functions of the room- and radio components 11.7.1 Installation heatapp! repeater Unpack the heatapp! repeater and plug it into a free 230V outlet, which is located between the heatapp! gateway and the radio modules to be covered. 11.7.2 Including heatapp! repeater at heatapp! gateway In the menu of the heatapp! gateway select the menu item "Register / deregister"...
  • Page 89: Heatapp! Repeater S Installation

    Functions of the room- and radio components Now press the learn key (1) on the side of the heatapp! repeaters S with an unfolded paper clip for 2-3 seconds. If the heatapp! gateway recognizes the heatapp! repeater S, the heatapp! repeater S is added to the heating configuration.
  • Page 90: Functions Of The Learn Key Heatapp! Repeater S

    Functions of the room- and radio components 11.7.9 Functions of the learn key heatapp! repeater S Fig.: 68: Functions of the learn keyheatapp! repeater S S. 90...
  • Page 91: Window Sensor

    Functions of the room- and radio components 11.8 Window sensor Fig.: 69: Window sensors Some Z-wave window contacts of other manufacturers have been implemented in the heatapp! system as heatapp! checked. The window contacts are registered and deregistered in the Gateway Menu Radio components > Login and Logout and assigned to a room.
  • Page 92 Functions of the room- and radio components Fig.: 71: Configuration menu window shutdown If window shutdown is activated (by selecting a time or ON), heatapp! regulates the room during the set window shutdown to the frost protection temperature. The rotary wheel on the homescreen is grey and disabled. Fig.: 72: Window sensor with activated window shutdown S.
  • Page 93: Wave Wireless Network

    Z-Wave wireless network Z-Wave wireless network heatapp! radio components communicate with the heatapp! gateway using the Z-wave wireless standard. The Z-Wave radio system is a wireless communication standard specially for use in the smart home sector. The wireless communication is optimised for low energy consumption and maximum communication safety. Z-wave uses two-way communication with acknowledgement.
  • Page 94: Testing The Wireless Coverage

    Radio coverage When radio waves penetrate solid material, e.g. walls or furniture, they are attenuated, that is absorbed. Metal objects reflect the radio waves. The reflection occurs on nearly all metallic surfaces (e.g. mirrors, thermal insulation foils) as well as materials (e.g. metal door frames, steel or sheet metal cabinets) and also on structural steel. Thermal insulation with metal foil lining also reflects the radio waves.
  • Page 95: Time Stamp Of The Radio Components

    Radio coverage 13.1.1 Time stamp of the radio components In Connection Status all radio components are listed with a time stamp and a status dot. Fig.: 74: Time stamp of the radio components The time stamp indicates when the last cyclic message of the radio component was issued via the heatapp! gateway. Reporting cycles of the radio components heatapp! drive Every 5 minutes...
  • Page 96: Status Dots Of The Radio Components

    Radio coverage 13.1.2 Status dots of the radio components The status of the radio components is displayed using status dots in Connection Status. A red status dot indicates that there has been no communication with the heatapp! gateway for at least 90 minutes. An orange status dot indicates that the registration interview has not yet completed.
  • Page 97: Radio Module Connection Test

    Radio coverage  Execute the function "Repair radio system". See chapter "Repairing the radio system function" on page 91.  If this does not work, add a heatapp! repeater to improve wireless coverage. Repeat the repair of the radio system and then the connection test.
  • Page 98: Retrofitting Radio Modules

    Retrofitting radio modules Retrofitting radio modules 14.1 heatapp! radio modules Retrofitting of radio modules can be performed in two ways. • Using the heatapp! app on a tablet-PC (recommended). • Using a PC / laptop and a heatapp! USB-LAN adapter. Via the heatapp! App Where possible use the heatapp! App on a tablet connected to the customer's home network for subsequent retrofitting of additional radio modules.
  • Page 99: Including Of Foreign Devices

    Retrofitting radio modules Fig.: 75: Representation of third party components 14.2.1 Including of foreign devices: Login into your system as Expert or Owner from a tablet using the heatapp! app. To to the "Settings" area, scroll the icons right down and select "Gateway". If necessary, login to the heatapp! gateway using the gateway password created during the initial setup.
  • Page 100: Restoring The Factory Settings

    Restoring the factory settings Restoring the factory settings In exceptional cases it may be necessary to reset heatapp! components to the factory settings. Resetting a running system always results in a new setup. A heatapp! system comprises several individual components. Therefore, a reset of individual components has different consequences for the components remaining in the system.
  • Page 101: Parameterlist Heatapp! Base

    Parameterlist heatapp! base Parameterlist heatapp! base 16.1 Menu – System Display condition Display condition Adjust- Menu / depending on the depending on the ment Discription Parameter EG connection EG connection range with gateway without gateway … Expert / system clima zone off, -20,0 Setting of the coldest expected outdoor temperature value.
  • Page 102: Menu - Hot Water

    Parameterlist heatapp! base 16.2 Menu – hot water 16.2.1 Information Menu / Display Description Display condition Display condition Parameter depending on the depending on the EG connection EG connection with gateway without gateway … Expert / hot water / information operation automatic Operation according to switching time program active mode...
  • Page 103: Heating Mode

    … 60min. legionella temperature takes place for the duration set here. … protection 240min. Note X2: The setting of the Legionella protection for T2B connection is done at the connected THETA controller. 16.2.4 Reset Menu / Adjust- Description Display condition...
  • Page 104: Menu - Room 1

    Parameterlist heatapp! base 16.3 Menu – Room 1 ... n / Room group 1 ... n 16.3.1 Information Menu / Display Description Display condition Display condition Parameter depending on the depending on the EG connection EG connection with gateway without gateway …...
  • Page 105 Parameterlist heatapp! base Menu / Display Description Display condition Display condition Parameter depending on the depending on the EG connection EG connection with gateway without gateway … Expert / Room group resp. Room / information battery sensor xx % Battery status of the heatapp! sense state valve Display of the current position of a valve (floor) for single off, on...
  • Page 106: Basic Settings

    Parameterlist heatapp! base 16.3.2 Basic settings Display condition Display condition depending on the depending on the Adjust- Menu / EG connection with EG connection ment Description Parameter gateway without gateway range EG connection with gateway … Expert / room group resp. room / basic settings Outside temperatu Selection of the request for the room/room group.
  • Page 107: Room Settings

    Parameterlist heatapp! base 16.3.3 Room settings Display condition Display condition Adjust- Menu / depending on the depending on the ment Description Parameter EG connection EG connection range with gateway without gateway … Expert / room group resp. room / room settings Economy Setting the room setpoint temperature for heating mode.
  • Page 108: Heating Mode

    Parameterlist heatapp! base 16.3.4 Heating mode Display condition Display condition Adjust- Menu / depending on the depending on the ment Description Parameter EG connection EG connection range with gateway without gateway … Expert / room group resp. room / heating mode lowering standby, Selection of the operating mode for lowering operation.
  • Page 109: Menu - Energy Generator

    Parameterlist heatapp! base 16.4 Menu – energy generator 16.4.1 Information Menu / Display Description Display condition Display condition Parameter depending on the depending on the EG connection EG connection with gateway without gateway … Expert / energie generator / information state heating EG serves the request...
  • Page 110: Basic Settings

    Parameterlist heatapp! base 16.4.3 Basic settings Display condition Display condition Adjust- Menu / depending on the depending on the ment Description Parameter EG connection EG connection range with gateway without gateway … Expert / Energieerzeuger / Basic settings summer lock off, If the current outdoor temperature exceeds the set summer lockout, all requirements for the energy generator...
  • Page 111: Reset

    Parameterlist heatapp! base 16.4.5 Reset Display condition Display condition Adjust- Menu / depending on the depending on the ment Description Parameter EG connection EG connection range with gateway without gateway … Expert / energy generator / reset reset off, Reset the parameters in the "energy generator" menu to factory settings according to the access authorization.
  • Page 112: Menu - Config

    Parameterlist heatapp! base 16.7 Menu – config The "Config" menu can be used to check information on the configuration of the system and the values available at the inputs. In addition, you can make further adjustments to the system that cannot be mapped using the setup wizard. 16.7.1 Information In the "Information"...
  • Page 113: Function

    Control of energy generators via data bus protocol (not for OpenTherm base t2b) regulator(T 2B/BUS) Control of the THETA controller via T2B bus (only for base t2b) Hot water supply not activated Hot water supply via automat (OT) automat hot water...
  • Page 114: Room Group Resp. Room

    Parameterlist heatapp! base 16.7.3 room group resp. room Display condition Display condition Adjust- Menu / depending on the depending on the ment Description Parameter EG connection EG connection range with gateway without gateway … expert / config / function / room group resp. room No energy generator available energy Active energy supply by energy generator via switch...
  • Page 115: Rectification Of Malfunctions

    Rectification of malfunctions Rectification of malfunctions Malfunctions are displayed in the app on the home screen as a “warning triangle” symbol. It will be shown in the top centre and in the room. Depending on the setting, the user receives error messages via e-mail and/or as a push message via their operating device.
  • Page 116: Led On Heatapp! Gateway

    Rectification of malfunctions 17.2 LED on heatapp! gateway Description Steady white Start sequence step 1 - power supply switched on Boot error - If the LED light up in white after switch on for more than two minutes, disconnect the heatapp! gateway from the power supply and wait for one minute.
  • Page 117: Fault Messages Of The Heatapp! System

    If possible, use a repeater to improve the radio coverage. Interface is interrupted This message occurs when the heatapp! base is connected to the energy provider via Open Therm or T2B bus and the data link is interrupted. Interface reports a malfunction...
  • Page 118 Rectification of malfunctions interface cannot be reached. In this case, the technician can only proceed with troubleshooting while on-site. The error messages of the energy provider/controller can only be forwarded to a limited extent, and the error messages can only be used for information purposes.
  • Page 119: Technische Daten

    Technische Daten Technische Daten 18.1 heatapp! base heatapp! base is the central control and regulation unit of the system. heatapp! base can be connected to the heat generator of an existing system and transmit the heat demand to the heat generator. In this way genuine single room heat regulation with demand requests is possible in accordance with EN 15232.
  • Page 120: Heatapp! Base T2B

    In this way genuine single room heat regulation with demand requests is possible in accordance with EN 15232. Using the heatapp! base T2B up to four heatapp! drive / heatapp! floor channels can be controlled per room. A maximum of 24 rooms can be controlled.
  • Page 121: Drilling Template Heatapp! Base / Heatapp! Base T2B

    Technische Daten 18.3 Drilling template heatapp! base / heatapp! base T2B Fig.: 76: Drilling template heatapp! base S. 121...
  • Page 122: Heatapp! Gateway

    (heatapp! floor), the electrical heaters (heatapp! single floor) and for room temperature measurement (heatapp! sense and heatapp! sense control) and serves as a message interface for heatapp! base/heatapp! base T2B and heatcon! EC. Scope of delivery: •...
  • Page 123: Heatapp! Drive

    Technische Daten 18.5 heatapp! drive heatapp! drive is a wireless actuator for flow-controlling a radiator. heatapp! drive communicates wirelessly with the heatapp! gateway. Scope of delivery: • Thermostat heatapp! drive • Batteries 2 x 1.5V AA alkaline • Adapter M30x1.5 thread •...
  • Page 124: Heatapp! Floor

    Technische Daten 18.6 heatapp! floor heatapp! floor is a control system for underfloor heating systems floor and -heating coils. Up to eight channels each with up to three thermoelectric actuators can be controlled. A maximum of 24 thermoelectric actuators (not supplied) can be connected.
  • Page 125: Heatapp! Sense

    Technische Daten 18.7 heatapp! sense heatapp! sense is a wireless room sensor for measuring the current temperature of the room. heatapp! sense communicates wirelessly with heatapp! gateway. Scope of delivery: • heatapp! sense • Batteries 2 x 1.5 V AAA alkaline Article number: 9600050000 Technical data Type of installation...
  • Page 126: Heatapp! Sense Control

    Technische Daten 18.8 heatapp! sense control heatapp! sense control is a wireless room sensor for measuring the current temperature and the damp of the room. sense control heatapp! sense control communicates wirelessly with heatapp! gateway. Permanent display of setpoint and actual temperature Display damp Scope of delivery: •...
  • Page 127: Heatapp! Repeater

    Technische Daten 18.9 heatapp! repeater The heatapp! repeater is used if there is no wireless connection between the radio modules and the heatapp! gateway due to the limited wireless range. The heatapp! repeater is positioned between the radio module and the heatapp! gateway, i.e.
  • Page 128: 18.10 Heatapp! Repeater S

    Technische Daten 18.10 heatapp! repeater S The heatapp! repeater S is used if there is no wireless connection between the repeater S radio modules and the heatapp! gateway due to the limited wireless range. The heatapp! repeater S is positioned between the radio module and the heatapp! gateway, i.e.
  • Page 129: 18.11 Heatapp! Wlan-Stick

    Technische Daten 18.11 heatapp! WLAN-Stick The heatapp! Wi-Fi-stick is used if a direct connection of the heatapp! base to the home network via a network cable is not possible. A Wi-Fi connection to the home network is made via the heatapp! Wi-Fi- stick.
  • Page 130: Heatapp! Usb-Lan Adapter (Installationskit)

    Technische Daten 18.12 heatapp! USB-LAN Adapter (Installationskit) The heatapp! USB-LAN Adapter is required for the initial operation of the heatapp! base and the heatapp! gateway. A direct connection is made between the devices and the installation PC/laptop via the heatapp! USB-LAN adapter. The heatapp! USB-LAN Adapter is plugged into one of the two USB ports of the heatapp! base or the heatapp! gateway.
  • Page 131: 18.13 Heatapp! Installations-Stick

    Technische Daten 18.13 heatapp! Installations-Stick The heatapp! Installation Stick is used for the initial installation of the heatapp! system by the Expert. A WLAN/Wi-Fi connection to the tablet or smartphone of the installer is created via the heatapp! Installation Stick. The heatapp! Installation Stick is plugged into one of the two USB ports on the heatapp! base or the heatapp! gateway.
  • Page 132: 18.14 Heatapp! Checked Komponenten Anderer Hersteller

    Technische Daten 18.14 heatapp! checked Komponenten anderer Hersteller Image Manufacturer Type designation Function Flush-mounted switch Aeon labs Aeotec Micro Aeon Labs LLC Switch G2 AEOTEC  DSC18103-ZWEU https://aeotec.com  The flush-mounted switch is integrated DSC26103-ZWEU as a heatapp! single floor in the (no longer available) heatapp! system and used in conjunction with a heatapp! sense /...
  • Page 133 Technische Daten The window contact is integrated in the Window contact heatapp! system. The function must be Aeon Labs LLC configured in the menu Expert > Room > Aeotec Door/Window AEOTEC Sensor Gen5 Room settings in heatapp! base. https://aeotec.com DSB29-ZWEU Individual Function setting...
  • Page 134: Login Data

    Login data Login data 19.1 Note the login data to your heatapp! system here: User level User name Password Expert _______________________________ _______________________________ Owner _______________________________ _______________________________ When connecting to the single room control heatapp! please record the password of the heatapp! gateway here: heatapp! gateway Password: _______________________________________________________________...
  • Page 135 Login data 0450000542-1927_BA-heatapp! System_EbV_EN.docx  Copyright by EbV Elektronikbau- und Vertriebs-GmbH Heisterner Weg 8-12 D-57299 Burbach Federal Republic of Germany S. 135...

This manual is also suitable for:

FloorRepeaterGatewaySenseDriveBase ... Show all

Table of Contents