  • Page 2: Table Of Contents

    TABLE OF CONTENTS: PAGE USER/OPERATOR SECTION Overview of system System Components Cheetah Display Unit Variable Frequency Drives Vacon 100 Keypad Navigation (and Reset) TECHNICAL SECTION Vacon 100 Key Settings Cheetah Input/Output unit Single Phase (230V) VFD Maintenance Error Codes (Cheetah Display) Vacon 100 Fault Codes EC Certificate of Conformity Warranty Information...
  • Page 3: Overview Of System

    The Cheetah system is installed with remote GPRS communications and data-logging facilities. This allows systems installed at sites to be remotely accessed by Quintex (as required) and the system/s performance operation can be monitored over a period of time.
  • Page 4: System Components

    Cheetah system. Other VFDs may be accommodated with the use of a Cheetah Input/Output unit. DATA-LOGGER (RCDLU) The Cheetah Remote Communications Data Logger Unit provides direct communications to the Cheetah system via a GPRS modem. It can be accessed by the Quintex technical department. 671697...
  • Page 5: Cheetah Display Unit

    ENERGY EXHAUST TEMP OVERRIDE SCROLL DISPLAY Quintex Systems Ltd Finchampstead RG40 4QQ www.quintex.co.uk In normal operation the Cheetah Display LED screen will show the active extract motor power saving that is being made. It does not show the running speed of the system – running speed/s can be accessed by use of the SCROLL button.
  • Page 6 SCROLL BUTTON OPERATION. The Cheetah display unit has various screens that can be accessed in order to view the real-time operation of the system. Additional operating information can be accessed by pressing the SCROLL button, as shown in the diagram below. Cheetah systems installed with multiple canopies and/or fans may show more information on the display screen.
  • Page 7 Any adjustments can only be made by a trained engineer. Adjustments can be made either; on-site with the use a laptop installed with the required software and network connection hardware), or remotely - by Quintex. There are no user-adjustable Cheetah parameters. 671697...
  • Page 8: Variable Frequency Drives

    VARIABLE FREQUENCY DRIVES: Vacon 100: A Vacon 3-phase AC VFD is used to adjust the speed that ventilation fans run at by changing the frequency of the electrical supply voltage. Single-phase Vacon20 VFDs are also available when required and are covered later in this manual.
  • Page 9 (installed with specialist application software) that will operate correctly with Cheetah, when installed as a fully networked (LonWorks) system. Any replaced VFD will have to be configured into the Cheetah system network by a trained Quintex engineer, with the appropriate equipment.
  • Page 10: Vacon 100 Keypad Navigation (And Reset)

    VACON 100 KEYPAD NAVIGATION (and RESET) The Vacon Inverters installed with the Cheetah system have a unique, bespoke software-application installed to allow them to operate with the digital (LonWork) communications of the Cheetah controls. The Inverter functions are checked during commissioning and should not normally require adjustment. If parameter adjustment is necessary this should be carried out with reference to the Vacon Instruction Manuals and the key setting parameters, by trained personnel.
  • Page 11: Vacon 100 Key Settings

    VACON 100 VFD KEY SETTINGS: During the commissioning of a Vacon 100 VFD the installation technician will set each VFD to operate with the motor to which it has been connected. It is essential that two key parameters are set correctly so that they match the specifications motor that the VFD is connected to.
  • Page 12: Cheetah Input/Output Unit

    CHEETAH INPUT-OUTPUT UNIT: Some ventilation systems have pre-existing VFDs that cannot accept digital (LonWorks) controlled instructions. Other VFDs, and devices such as EC fans, are not able to be LonWorks controlled. For applications of this type there is the option of installing a Cheetah Input-Output unit. The Input-Output unit has been specifically designed to convert digital (LonWorks) communications signals to analogue control signals (it is a D-to-A converter).
  • Page 13 DETAILED DESCRIPTION OF CHEETAH INPUT/OUTPUT TERMINALS:  Analogue OUTPUT (0-10V) control signal [Available on terminal 6 – (WHITE conductor), with terminal 5 – (BLACK conductor) as the ground] This output provides the reference signal to an external device and is the commanded (percentage) fan running speed instruction from the Cheetah system.
  • Page 14: Single Phase (230V) Vfd

    SINGLE PHASE (230V) VFD Single phase motors can be controlled by the Cheetah system with the use of a Vacon20 VFD. The Vacon20 has been specially adapted to run a single-phase (230V) AC motor. The connections and parameter settings for the installation are shown below. Alterations to the configuration and parameters should only be made by (or in association with) a trained technician.
  • Page 15: Maintenance

    MAINTENANCE Cleaning Optic Sensors The Cheetah laser optic sensor and related circuit boards are contained within stainless-steel enclosures – with (internal) dirt-repellent clear covers installed over the laser apertures. It is recommended that the optic sensors are wiped (with a clean damp cloth) once a week to maintain a ‘clear window’. Sustained direct pressure-jet washing of the laser aperture cover areas should be avoided.
  • Page 16: Error Codes (Cheetah Display)

    AIR HANDLING SYSTEM: The Cheetah system relies on the equipment that it is controlling (the extract and supply ventilation air systems) to be in a good state of operational order so that it can operate at optimum efficiency and produce the best results. It is expected that the ventilation systems are sufficiently maintained;...
  • Page 17: Vacon 100 Fault Codes

    VACON 100 FAULT CODES (ABRIDGED) Fault Code Fault ID Fault Name Possible Cause How to correct the fault Overcurrent Current draw is too high a (>4*I H) in the motor Check the VFD loading. Check of the (hardware fault) cable. The possible cause can be one of these: motor, check of the cables and connections.
  • Page 18 System fault Defective component. Operation malfunction Reset the fault and restart the drive. If the fault re-occurs again, contact the Vacon distributor. Configuration error, software error. Defective component (control board), operation malfunction. Defective component. Operation malfunction Software is not compatible with the application Resource overload.
  • Page 19 Motor underload There is not sufficient load on the motor Check the load. Check of the parameters. Check of the du/dt and sinus filters. Power overload The power of the drive is too high Decrease the load. (short time supervision) Check the VFD is suitably sized for the load.
  • Page 20 1654 Slot D fault 1754 Slot E fault 1366 Thermistor input 1 The motor temperature increased. Check the motor cooling and the load. fault Check the thermistor connection. If the 1466 Thermistor input 2 thermistor input is not used, it has to fault linked-through.
  • Page 21: Ec Certificate Of Conformity

    EC CONFORMITY AND WARRANTY INFORMATION. WARRANTY INFORMATION: COMPONENTS OF THE CHEETAH SYSTEM (DISPLAY UNIT, SENSOR-PROCESSOR/S, OPTICAL SENSORS, TEMPERATURE SENSORS) HAVE A (12MONTH) ONE-YEAR WARRANTY FROM THE DATE OF INSTALLATION, FOR MANUFACTURE DEFECTS. THE VACON FREQUENCY INVERTERS HAVE A (12MONTH) ONE-YEAR WARRANTY FROM THE DATE OF INSTALLATION. MALICIOUS OR ACCIDENTAL DAMAGE OF ANY PARTS OF THE CHEETAH SYSTEM WILL INVALIDATE ANY WARRANTY CLAIMS.
  • Page 22: Electrical Schematic Wiring Diagram

    ELECTRICAL SCHEMATIC WIRING DIAGRAM THE DIAGRAM SHOWS A BASIC CHEETAH SYSTEM WITH A SINGLE-SENSOR PROCESSOR, PLUS EXTRACT & SUPPLY VENTILATION FANS. 671697...