USER'S MANUAL
For use by qualified professionals only
This manual must be read thoroughly and understood prior to using the VALIANT™ Curing Light.
Inter-Med, Inc.
2200 South St.
Racine, WI 53404-2500 - U.S.A.
Tel.: +1-262-636-9755
Fax: +1-262-636-9760
Toll Free: +1-877-418-4782
www.vista-dental.com
601000
Emergo Europe
Prinsessegracht 20
2514 AP The Hague
The Netherlands
601000-I-V-17-ENG (6)

Advertisement

loading
Need help?

Need help?

Do you have a question about the Valiant 601000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vista Valiant 601000

  • Page 1 This manual must be read thoroughly and understood prior to using the VALIANT™ Curing Light. Emergo Europe Inter-Med, Inc. 2200 South St. Prinsessegracht 20 Racine, WI 53404-2500 - U.S.A. 2514 AP The Hague Tel.: +1-262-636-9755 The Netherlands Fax: +1-262-636-9760 Toll Free: +1-877-418-4782 601000-I-V-17-ENG (6) www.vista-dental.com...
  • Page 2 Introduction ..........3 Welcome to Vista Dental’s VALIANT™ ......3 Contents of the VALIANT™...
  • Page 3 Welcome to Vista Dental’s VALIANT™ Congratulations on your decision to incorporate the VALIANT™ curing light into your practice. Vista Dental’s VALIANT™ curing light uses multiple wavelengths (395 – 500nm) to cure mostly all polymerizable dental materials, making it one of the most versatile curing lights on the market. The VALIANT™...
  • Page 4 Unpacking the Container No special assistance is required to unpack and assemble the VALIANT™. If you have questions or concerns, please visit www.vista-dental.com or call Vista Dental Products at 877.418.4782 (Toll Free). Packaging should be inspected upon arrival for evidence of shipping damage.
  • Page 5 Attaching the Battery Pack to the Handpiece (or Charging Cap) 1. Line up the triangle on the battery pack with the triangle on the handpiece or charging cap. 2. Insert the battery pack into the handpiece (or charging cap) until the arrow clicks;...
  • Page 6 Attaching and Removing the Curing Light Shield 1. Snap the shield onto the neck of the VALIANT™ Curing Light by lining up the open area of the shield with the unit’s neck and pressing firming until the shield clicks on (see image below). Area to snap on/off the curing light shield Press firmly on the...
  • Page 7 Charging the Battery Pack The VALIANT™ battery packs are partially charged when shipped. Before you turn on and start using the device, you must insert a battery pack into the handpiece (or charging cap) and fully charge the battery pack before using it for the first time.
  • Page 8 VALIANT™ Operation The handpiece is capable of emitting multispectral curing light (broad spectrum blue light) and white light (for transillumination and general visualization). You can select and control the various operations of the handpiece by rotating the mode selection knob to the desired setting and using the ON/OFF button to initiate or halt light emission.
  • Page 9 Transillumination Mode The transillumination mode can be executed on any mode by depressing the ON/OFF button until white light mode is engaged. Disinfection / Sterilization The VALIANT™ Curing Light is provided non-sterile. There are not any special accessories needed to sterilize the VALIANT™ Curing Light parts. Quaternary ammonium compound products are recommended (containing 20% alcohol or less).
  • Page 10 The barrier sleeve helps keep dental materials from adhering to the surface of the lens. Troubleshooting Guide If the suggested solutions do not rectify the problem, please call Vista Dental 877.418.4782 (Toll Free). Problem Possible Solution Light will not turn on 1.
  • Page 11 Technical Data Technical Information VALIANT™ Cordless LED Curing Light Wavelength Range 395-500nm (see graph below). VALIANT™ optical power falls between 395-500nm. Minimal and insigni cant power can be found in wavelength ranges <39nm and >500nm. VALIANT ’s Wavelength Spectrum ™ Lower wavelength band Upper wavelength band 400-420nm...
  • Page 12 Symbol Identification Description for additional symbols. Follow instructions Serial Number for use Temperature Manufacturer Limitation Manufacturing Date Humidity Limitation Atmospheric Protected Class II Pressure Limitation Electrical Insulation Type BF Batch Code / Lot Number Applied Part Authorized European Keep Dry Representative Part Number Perscription Only...
  • Page 13 Battery Pack Disposal Batteries contain toxic material and should not be disposed of in landfills or incinerators. Dispose of depleted batteries as directed by your local solid waste handling regulations. To dispose of the battery pack, we recommend www.call2recycle.com (for North America) to locate a recycling facility near you. Safety Notes, Warnings and Precautions Read all instructions before operating this unit.
  • Page 14 WARNING • The user should test the product before use to ensure proper functionality. • The user should test the VALIANT™’s optical power using a radiometer prior to use. • An irradiance value 800-1750mW/cm2 is acceptable for standard and ramp modes, and a value 1350-3300mW/cm2 is acceptable for boost mode •...
  • Page 15 CAUTION • U.S. Federal law restricts the sale of this device by or on the order of a healthcare professional. Use of the device is restricted to qualified and trained personnel only in accordance with the instructions below. The manufacturer assumes no liability for any damage arising from any other or improper use of this device.
  • Page 16 • Only Vista Dental Products may open the device housing and repair the device. • VALIANT™ must not be used in patients, or by users, with heart pacemaker implants who have been advised to be cautious with regard to their exposure to small electrical devices.
  • Page 17 Operating Conditions and Safety Consideration Heat generation The metal parts of the VALIANT™ Curing Light do not overheat to the point of discomfort or injury during standard operating durations (i.e. five consecutive standard mode, ramp mode or boost mode cures). However, care should be taken to allow the product to completely cool to room temperature between patients (approximately two minutes), to ensure overheating does not occur.
  • Page 18 VALIANT™ curing light. In the event of a defect in material or workmanship, Vista Dental Products is limited, at its option, to replace of the defective product, a part thereof, or reimbursement of the actual cost of the defective product.
  • Page 19 Return Policy Vista Dental Products will accept for return previously purchased merchandise which is suitable for resale or was shipped in error by Vista Dental Products. Merchandise suitable for resale requires current labeling and unopened non- soiled packaging. All returns must have prior approval and must be shipped “prepaid” along with a return authorization form and a copy of the original invoice.
  • Page 20 Appendix – Electromagnetic Compatibility and Electrical Safety Information The VALIANT™ Curing Light is tested according to IEC 60601-1-2, Edition 3.0. Medical electrical devices are subject to particular preventive action according to EMC rules and must be installed and operated according to the EMC guidelines in the accompanying documents.
  • Page 21 Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance 70% UT 70% UT (30% dip in UT) for 25 (30% dip in UT) for 25 cycles cycles <5% UT <5% UT (>95% dip in UT) for 5 (>95% dip in UT) for 5 sec sec Power frequency Power frequency magnetic fields should be at (50/60Hz) magnetic 3 A/m 3 A/m levels characteristic of a typical location in a field IEC 61000-4-8 typical commercial or dental environment. Portable and mobile RF communications equipment should not be used closer to any part of Valiant, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance Conducted RF IEC 3 Vrms d = 0.35 √P 61000-4-6 150 kHz to 80 MHz d = 0.35 √P 80 MHz to 800 MHz d = 0.70 √P 800 MHz to 2.5 GHz Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as Radiated RF 3 V/m determined by an electromagnetic site survey (a), 10V/m...
  • Page 22 Recommended Separation Distances Between Portable and Mobile RF communications equipment and the “VALIANT™ Curing Light” The VALIANT™ is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the VALIANT™ can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the VALIANT™...
  • Page 23 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...