Aigis Mechtronics MT9230 Installation And Operating Instructions Manual

Parapet mount

Advertisement

Quick Links

End Cap with O-Ring
Pipe Arm
1/4 x 20 x 5/16"
Pan Head Screw SS
Pipe Arm
Wall Mount
END CAP
1/4 x 20 x 5/16
SCREW
STAINLESS STEEL
(1 INCLUDED)
PIPE ARM
MOUNTING
BRACKET
101.6
]
[
4.00
0.41
TYPICAL
.63 Typ.
8x Ø 10.3
[
]
.41
11.00
I
N S T A L L A T I O N A N D
75.69
[ [
2.980
]
228.6
[
9.00 ]
14.88
279.4
[
]
11.00
REFERENCE: 2-1/2" O.D. X 3/16" WALL
HOLE TAPPED FOR 1/4-20 THREADED EYE BOLT (FOR GUY WIRES)
3/8-16 S.S. Hex Head Bolt
1-1/2 NPT
69.9
[
]
2.75
1038.2
[
]
40.88
.25 Typ.
581.4
[
]
22.89
4.37 Typ. 10.00
Square
.63 Typ.
976.1
[
38.43
[
Hole pattern to match that
of Wall Mount, MT9230
8 Fastener holes shown.
Use a minimum of 6 Fasteners.
Apply sealant
around each
fastener hole.
3/8-18 x 3/4 HEX
HEAD BOLT
STAINLESS STEEL
(3 INCLUDED)
531.2
[
]
20.92
MOUNTING
SURFACE
]
1022.4
O
]
40.25
P E R A T I N G
90.4
[
]
3.56
P
M
ARAPET
1190.6
[
]
46.88
MT9230
30.2
[
1.19 ]
CABLE
CLEARENCE
USING ROOF
MOUNT.
I
N S T R U C T I O N S
mm
[in.]
OUNT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MT9230 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aigis Mechtronics MT9230

  • Page 1 N S T A L L A T I O N A N D 40.25 P E R A T I N G N S T R U C T I O N S Hole pattern to match that 75.69 of Wall Mount, MT9230 2.980 90.4 [in.] 228.6 3.56 9.00 ]...
  • Page 2 12. Power Lines - An outdoor system should not be located in the IMPORTANT SAFEGUARDS vicinity of overhead power lines or other electric light or power 1. Read Instructions - All the safety and operating instructions circuits, or where it can fall into such power lines or circuits. should be read before the unit is operated.
  • Page 3 SAFETY PRECAUTIONS DESCRIPTION The exclamation point within an equilateral triangle The MT9230 is a stationary mount intended for roof top is intended to alert the user to presence of parapet walls. This mount will accommodate products important operating and maintenance (servicing) designed for standard 1 1/2”...
  • Page 4 (see Figure 2). Install the mounting bracket and tighten all fasteners securely. Figure 1: MT9230 with End Cap removed Insert the pipe arm into the mounting bracket until it bottoms. Feed all electrical and control cables through the pipe...
  • Page 5 8 Fastener holes shown. Use a minimum of 6 Fasteners. Pipe Arm Wall Mount Apply sealant around each fastener hole. 3/8-16 S.S. Hex Head Bolt Figure 2: Installation of Wall Mount may be easier if the pipe arm end cap is removed (see 11.
  • Page 6 Finish: White 8.1 MT9230 Parapet Mount Dimensions: See Figure 3. Mounting: Do not mount the MT9230 in an inverted posi- Weight: 7.7 kg (17 lb.) tion. Mounting hardware not furnished. Maximum Load: 29 kg (64 lb.). Load center of gravity located in line with load attachment point.
  • Page 7 Mounting hardware not furnished. Dimensions: See Figure 4. Maximum Load: 37 kg (81 lb.). Total load equal to one Weight: 3.6 kg (8 lb.). model MT9230 Parapet Mount at full rated capacity. .25 Typ. 0.41 4.37 Typ. 10.00 .63 Typ.
  • Page 8 ©2006 Aigis Mechtronics 1124 Louise Road, Winston-Salem, NC 27107-5450 Tel: 336.785.7740 Fax: 336.785.7744 100 0046 002 AIG 05/06 WWW.AIGISMECH.COM Printed in U.S.A. Data subject to change without notice...

Table of Contents