Air Monitor Corporation VOLU-probe/1 Installation Procedure

Advertisement

Quick Links

INSPECTION & HANDLING. VOLU-probes should be carefully inspected for damage prior to installation. Report
damage to your Freight Department, or contact delivery carrier.
Almost any means of handling can be utilized depending on the length and width of the probes. Probes may be
handled while in any position; however, it is important not to drop or mishandle the probes such that damage is
done to the sensing holes, tubular members, signal connection fittings, end studs, or mounting plates.
Air Monitor Corporation (hereinafter referred to as "Seller") warrants that at the time of shipment, products sold
pursuant to this contract will be free from defects in materials and workmanship, and will conform to the
specifications furnished or approved in writing by Seller. No warranty is given that delivered products will
conform to catalog sheets, data sheets, and the like, which are subject to change without notice.
Seller will repair or replace, at its option, any products listed under this warranty which is returned freight pre-
paid to Seller and within the earlier of two (2) years after start-up or twenty-seven (27) months after shipment,
prove upon test and examination by Seller to be defective within the terms of this warranty. The warranty period
for any item repaired or replaced shall be for the time remaining on the warranty period for the original
components. Purchaser shall notify Seller in writing of such defect within sixty (60) days of discovery of the
defect.
This warranty does not extend to any product sold by Seller which has been the subject of misuse, neglect,
accident, damage or malfunction caused by interconnection with equipment manufactured by others, improper
installation or storage, or used in violation of instructions furnished by Seller, nor does it extend to any product
which has been repaired or altered by persons not expressly approved by Seller. Nor does Seller warrant
equipment against normal deterioration due to environment; nor items such as thermocouples, electrodes, and
similar items subject to wear or burnout through usage. Adjustments for items or equipment not manufactured
by Seller shall be made to the extent of any warranty of the manufacturer or supplier thereof.
Seller shall not be liable for any special or consequential damages or for loss of damage directly or indirectly
arising from the use of the products.
The warranty set forth above is in lieu of all other warranties either express or implied and constitutes the full
extent of Air Monitor Corporation's liability to the customer, or any other party for breach of warranty. THERE
ARE NO EXPRESS WARRANTIES EXCEPT AS SET FORTH HEREIN. THERE ARE NO IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, WHICH ARE
PARTICULARLY DISCLAIMED.
VOLU-probe/1, /3, /4 for Round Ducts

WARRANTY

INSTALLATION PROCEDURE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VOLU-probe/1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Air Monitor Corporation VOLU-probe/1

  • Page 1 The warranty set forth above is in lieu of all other warranties either express or implied and constitutes the full extent of Air Monitor Corporation's liability to the customer, or any other party for breach of warranty. THERE ARE NO EXPRESS WARRANTIES EXCEPT AS SET FORTH HEREIN. THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, WHICH ARE PARTICULARLY DISCLAIMED.
  • Page 2 VOLU-probe/1, /3, /4 for Round Ducts – Installation Procedure ORIENTATION OF PROBES. Using the AIRFLOW directional arrow on the probe mounting flange to determine correct orientation, install VOLU-probes with sensing holes facing airflow. INSTALLING VOLU-probes. To achieve published performance standards, the location of VOLU-probes in ductwork must comply with the Minimum Requirements for Installation (Page 7).
  • Page 3 The maximum length of a VOLU-probe/4 is 72". VOLU-probe/1 and VOLU-probe/3 over 10 feet in length require mid-span support to eliminate excessive droop or oscillation during operation.
  • Page 4 VOLU-probe/1, /3, /4 for Round Ducts – Installation Procedure DIMENSIONAL SPECIFICATIONS. VOLU-probe/1 VOLU-probe/3...
  • Page 5 VOLU-probe/1, /3, /4 for Round Ducts – Installation Procedure DIMENSIONAL SPECIFICATIONS (con't) VOLU-probe/4...
  • Page 6 VOLU-probe/1, /3, /4 for Round Ducts – Installation Procedure INTERCONNECTING TUBING. Interconnecting tubing and fitting makeup is to be 1/4". If rigid tubing is required, the fittings at the probes and for the interconnecting tubing will be compression fittings. If flexible tubing is required, all fittings will be brass or plastic barbed type.
  • Page 7 VOLU-probe/1, /3, /4 for Round Ducts – Installation Procedure AIRBORNE CONTAMINANTS. The levels of air filtration and cleanliness associated with commercial HVAC Systems, whether supply/return/ exhaust/outside air, are satisfactory for operation of the VOLU-probe. Industrial applications containing airborne contaminants may require periodic manual or automatic cleaning using compressed air applied to the signal fittings, and/or removal from the duct or stack for physical cleaning.
  • Page 8 List the Return Authorization (R/A) number on the packing list and clearly mark this number on the outside of each shipping container. Costs associated with the return of equipment to Air Monitor Corporation are the customer’s responsibility regardless whether the repair/return is under warranty. Once the Customer Service Department determines that the equipment repair is under warranty, the item will be repaired and returned to the customer at no charge.

This manual is also suitable for:

Volu-probe/3Volu-probe/4

Table of Contents