iseg ECH 224 Technical Documentation Manual

iseg ECH 224 Technical Documentation Manual

4 slot 19” mms-crate series for mms high voltage power supply modules, up to 4 mms high voltage power supply modules, 300w, wide range of hv-modules, integrated fan unit

Advertisement

Quick Links

Technical documentation
last changed on: 25.05.2020
ECH 224
4 Slot 19" MMS-Crate Series for iseg MMS High Voltage Power Supply Modules
up to 4 MMS High Voltage Power Supply Modules
300W
wide range of HV-modules
integrated fan unit

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECH 224 and is the answer not in the manual?

Questions and answers

Summary of Contents for iseg ECH 224

  • Page 1 Technical documentation last changed on: 25.05.2020 ECH 224 4 Slot 19” MMS-Crate Series for iseg MMS High Voltage Power Supply Modules up to 4 MMS High Voltage Power Supply Modules • 300W • wide range of HV-modules • integrated fan unit...
  • Page 2: Document History

    Copyright © 2020 by iseg Spezialelektronik GmbH / Germany. All Rights Reserved. This document is under copyright of iseg Spezialelektronik GmbH, Germany. It is forbidden to copy, extract parts, duplicate for any kind of publication without a written permission of iseg Spezialelektronik GmbH. This information has been prepared for assisting operation and maintenance personnel to enable efficient use.
  • Page 3: Safety

    Advices marked as “Caution!” describe actions to avoid possible damages to property. CAUTION! INFORMATION Advices marked as “Information” give important information. INFORMATION Read the manual. Attention high voltage! HIGH VOLTAGE Important information. ECH 224 – 4 Slot MMS Crate | Last modified on: 25.05.2020 | www.iseg-hv.com 3/14...
  • Page 4: Intended Use

    You may only put the product into operation after it has been established that the high-voltage device complies with • the country-specific regulations, safety regulations and standards of the application. The high-voltage power supply unit may only be installed by qualified personnel. • ECH 224 – 4 Slot MMS Crate | Last modified on: 25.05.2020 | www.iseg-hv.com 4/14...
  • Page 5: Important Safety Instructions

    Do not operate the unit in an explosive atmosphere. WARNING! WARNING! Do not operate the unit if you suspect the unit or the connected equipment to be damaged. WARNING! ECH 224 – 4 Slot MMS Crate | Last modified on: 25.05.2020 | www.iseg-hv.com 5/14...
  • Page 6 When installing the units, make sure that an air flow through the corresponding air inlet and outlet openings is possible. CAUTION! INFORMATION Please check the compatibility with the devices used. INFORMATION ECH 224 – 4 Slot MMS Crate | Last modified on: 25.05.2020 | www.iseg-hv.com 6/14...
  • Page 7: Table Of Contents

    Operation and maintenance Front panel Bank select switch Forced air cooling Dimensional drawings Connectors and PIN assignments Accesories Order guides Appendix Warranty & Service Disposal Manufacturer contact ECH 224 – 4 Slot MMS Crate | Last modified on: 25.05.2020 | www.iseg-hv.com 7/14...
  • Page 8: General Information

    1 General information These crate devices are used for operating iseg high voltage power supply modules in a desktop compatbile case. Up to 4 slots for MMS high voltage modules are provided. Each module is connected to the backplane of the crate by a vendor specific 96 pin connector.
  • Page 9: Operation And Maintenance

    PC. If using Multi Channel iseg HV-modules with internal supplied safety loop, bridging the two pins of the SL connector on the front of the crate will be connect the module SL to the current source in the crate. If the module safety loop is active (see the...
  • Page 10: Bank Select Switch

    INFORMATION Further it is recommended to cover unused module slots with blind front panels to provide optimal airflow and cooling performance. INFORMATION ECH 224 – 4 Slot MMS Crate | Last modified on: 25.05.2020 | www.iseg-hv.com 10/14...
  • Page 11: Dimensional Drawings

    4 Dimensional drawings Figure 3: Dimensions ECH 224 ECH 224 – 4 Slot MMS Crate | Last modified on: 25.05.2020 | www.iseg-hv.com 11/14...
  • Page 12: Connectors And Pin Assignments

    Connector FFA.0S.302.CLAC / Z592312 Table 4: Part numbers 6 Accesories CAUTION! Only use genuine iseg parts like power cables, CAN cables and terminators for stable and safe operation. CAUTION! ACCESSORY ITEM ORDER ITEM CODE SHV coupler screw for RG58 Z590162 SHV coupler screw for >5kV...
  • Page 13: Order Guides

    [W] = 300W Tabelle 6: Order guides 8 Appendix For more information please use the following download links: This document http://download.iseg-hv.com/SYSTEMS/MMS/EHS/iseg_manual_ECH224_en.pdf Iseg HV Modules https://www.iseg-hv.com/ ECH 224 – 4 Slot MMS Crate | Last modified on: 25.05.2020 | www.iseg-hv.com 13/14...
  • Page 14: Warranty & Service

    11 Manufacturer contact iseg Spezialelektronik GmbH Bautzner Landstr. 23 01454 Radeberg / OT Rossendorf GERMANY FON: +49 351 26996-0 | FAX: +49 351 26996-21 www.iseg-hv.com info@iseg-hv.de sales@iseg-hv.de ECH 224 – 4 Slot MMS Crate | Last modified on: 25.05.2020 | www.iseg-hv.com 14/14...

Table of Contents