INTRODUCTION The AEL IR 4400 is a highly versatile and compact laser therapy device that, under the guidance of a qualified Veterinarian, provides a simple method of treatment, delivering relief from many common pain conditions. Because of its simple design and ease of operation, the AEL IR 4400 Therapy Unit is ideal for use either in a clinic or out in the field.
LOCATION OF PARTS OLED Display UP button DOWN button LED laser emission indicator light Identification label Battery cover Danger label Aperture warning label Certification label 10. On/Off switch 11. ENTER button 12. START / STOP button 13. Reset buttons (See following page for diagram showing part & label locations)
Page 6
LOCATION OF PARTS 8. Aperture label 4. LED Laser Emission indicator light 7. Danger Label 1. OLED Display 2. Up button 10. On / Off switch button 11. Enter button 3. Down button 13. Reset buttons 12. Start / Stop button 5.
LABELS The AEL IR 4400 comes with the following labels: Certification label – This label states that Laserex certifies that the AEL IR 4400 complies with 21CFR 1040.10 and 1040.11. This label appears on the front of the AEL IR 4400.
Place 2 batteries inside each of the slots at the end of the probe of the unit as per the – and + symbols. Place the battery cover back onto the probe. (When you receive the AEL IR 4400, the batteries will already be in the unit.)
2. Attaching the head Attach the selected head by screwing it in a clockwise motion onto the hand piece until it has tightened into place. This is done by placing the head onto the hand piece at the 10 o’clock position by lining up the notch and turning it clockwise to the 12 o’clock position.
Page 11
The PIN is factory set to 9999 by Laserex. The first 9 will appear on the screen. Press ENTER until the second asterisk becomes a 9, then press ENTER again until 9999 appear on the screen. After the 4 asterisk become a 9 the word OK will appear in yellow alongside ENTER on the screen.
Page 12
Frequency Selection: Frequency (Freq) will be highlighted in blue and Continuous Wave (CW) will appear highlighted in orange. If you wish to use the AEL IR 4400 in CW press ENTER to move to the Interlock setting. To change the frequency from CW to one of 7 programmed Nogier frequencies, press UP (with CW highlighted in blue) once to 73Hz, twice to 146Hz and so on.
Page 13
Press ENTER and the following screen appears As the AEL IR 4400 is a Class 3B laser, it requires a RF safety interlock. You will receive 2 of these with the unit. These can be placed either on the door or window of your office.
Page 14
It is now advisable to have the laser ready at the position where the subject is to receive treatment. Press the red START / STOP button and the AEL IR 4400 delivers the requested dosage. An audible beep will be heard and the Laser Emission indicator button on the front of the unit will be flashing in green.
Page 15
DOWN until SAVE is highlighted in blue. Press ENTER and the following screen appears: Press ENTER when M1 is highlighted. The AEL IR 4400 allows for the storing of 14 settings in memory. When OK is highlighted, press ENTER and it will be stored in memory.
Page 16
ENTER, an image of the laser safety eyewear will appear, then press the red START / STOP button. In case of emergency, press the 2 restart buttons (see diagram) simultaneously and the AEL IR 4400 will switch off. Changing a Dosage: After completing a treatment and you wish to change the dosage...
Page 17
Press UP so that PREV is highlighted and then press ENTER. Select Manual input and ENTER the appropriate settings. No Head Attached: If no head is attached to the AEL IR 4400, the following will appear on the screen: Press Enter with OK highlighted. The next screen will indicate the following: The AEL IR 4400 should be switched off and the head re-attached.
Page 18
At this stage, a beep will be audible. If the AEL IR 4400 is not to be used for an extended period of time, remove the batteries and place the unit in its carrying case.
CARE AND MAINTENANCE The AEL IR 4400 is a very sturdy device that is supplied with its own carry case. However, like any other electronic product, it requires proper care and handling. We recommend the following: Never try to disassemble the device.
The AEL IR 4400 comes with an AC Adaptor for battery re-charging. Plug the AC Adaptor into the hole on the side of the Laser AEL IR 4400 to re-charge the batteries. It will take 16 hours to re-charge the batteries from being flat to completely re-charged.