3-4-6. Connection of the head cable to a
display unit
1 First, remove the screws securing the screening plate
and remove the screening plate. (These screws are
used later.)
2 Check that the display unit power is off. Then, making
sure the interface unit of the connection cable is facing
the proper direction, gently insert the interface unit as
far as possible.
Note
Check the scale unit mounting axis and display unit
insertion.
Finally, secure the interface unit using the screws which
secured the screening plate. (tightening torque: 60 N·cm)
Rear panel of display unit
Screening plate
Fig. 3-15
Rear panel of display unit
Interface unit
Fig. 3-16