  • Page 1 Cute Thermal User Manual Copyright © 2020 Laia · www.laiatech.com All rights reserved...
  • Page 2: Table Of Contents

    Snapshot ................13 4.3.6 ................13 EMP MEASUREMENT Distance ................13 4.4.1 4.4.2 Calibration ................. 14 4.4.2.1 No blackbody mode ..........14 Blackbody mode ............ 14 4.4.2.2 DEPLOYMENT PRECAUTIONS ................ 15 Copyright © 2020 Laia · www.laiatech.com All rights reserved...
  • Page 3: Overview

    Overview CUTE THERMAL is a high-precision thermal imaging, which can measure the temp of target object online in real time, output thermal image video and check the over-temp condition. Going with different matching platform software, it can be suitable for different usage modes (such as power device temp measurement, fire alarm, human body temp measurement and screening).
  • Page 4: Specifications

    Specifications CUTE THERMAL specifications are as follows: Parameters Index Resolution 320x240 Response wave band 8-14um Frame rate NETD 70mK@25°C (77°F) Infrared Field angle 34.4 in horizontal, 25.8 in vertical thermal Lens 6.5mm imaging Measurement range -10°C - 300°C (14°C-572°C) Measurement For human body, the temp compensation algorithm can reach (±1.08°F)
  • Page 5: Connection Mode

    Connection mode Only one USB cable is needed to connect the thermal imaging machine and the computer. The connection mode and interface model are shown in the following figure Copyright © 2020 Laia · www.laiatech.com All rights reserved...
  • Page 6: Background Software

    This system only available for Win10 OS, and the background software interface is as follows: Driver installation After connecting the computer to the CUTE THERMAL camera with Micro USB 2.0 cable, open the "Device Manager", and locate the "Universal Serial Bus devices" or “other devices” or "PIR324 Thermal Camera"...
  • Page 7 Double click "DYTiRViewer.exe" to operate the software. Please refer to the following steps, if you are prompted that the driver cannot be installed due to driver hash value: Open the "Settings" and click “Update and Security”: Copyright © 2020 Laia · www.laiatech.com All rights reserved...
  • Page 8 Click "Recovery"- "Restart Now", After the computer is restarted, enter the following interface, click "Troubleshoot", Click "Advanced options": Copyright © 2020 Laia · www.laiatech.com All rights reserved...
  • Page 9 Click "Startup Settings": Click "Restart": After restarting again, enter the following screen, press the keyboard number 7 to restart, After the restart is completed, install the driver again. Copyright © 2020 Laia · www.laiatech.com All rights reserved...
  • Page 10: Software Application

    Select the camera in red box in the figure below, click the "Play", and the current image of the camera will be displayed on the right. Click "Stop" to stop displaying the real-time image. Click "Photo" to select "Folder" and save the image. Copyright © 2020 Laia · www.laiatech.com All rights reserved...
  • Page 11 Press the maximize icon in the upper-right of the image, the image and measured temperature value will be enlarged, and press again will change back the normal mode. Copyright © 2020 Laia · www.laiatech.com All rights reserved...
  • Page 12: Temp Measurement

    3.3.2 Temp measurement CUTE THERMAL infrared thermal imager needs 10min of preheating after start-up. After 10min, the thermal imager can output accurate temp values stably. View the start-up time at the top right of the software. Temp fluctuation is normal within 0.5°C (0.9°F). In context of human body temp...
  • Page 13: Zone Temp Measurement

    There are 1,2,3 for the label of the zone to differential different zones. 3.3.4 Color palette You can click "Color" at the red circle in the figure below to display the thermal image. Copyright © 2020 Laia · www.laiatech.com All rights reserved...
  • Page 14: Alarm

    Click this picture to view with Win10 default software. Temp measurement 3.4.1 Distance The measurement accuracy of the infrared thermal imager is affected by the distance to the Copyright © 2020 Laia · www.laiatech.com All rights reserved...
  • Page 15: Calibration

    The historical temp measurement curve of boldface will be displayed below. If this curve rises or falls sharply, it is necessary to check whether the blackbody Copyright © 2020 Laia · www.laiatech.com All rights reserved...
  • Page 16: Deployment Precautions

    At this time, the tested person can be allowed to being calm down for a while or cool, then measure and screen. Copyright © 2020 Laia · www.laiatech.com All rights reserved...