Advertisement

Quick Links

USER MANUAL
FR : Un manuel dans votre langue est disponible sur Internet:
IT: Il manuale nella sua lingua può essere trovato su Internet:
ES: Puede encontrar un manual en su idioma en Internet:
PT: Um manual em seu idioma pode ser encontrado na Internet:
PL: Instrukcję w swoim języku możesz znaleźć na stronie:
SWE: En handbok på ditt språk finns på Internet:
NL: Een handleiding in uw taal vindt u op internet:
www.easypix.info/download-manuals/download/pulseoximeter/

Advertisement

Table of Contents
loading

Summary of Contents for Easypix Pulse Oximeter

  • Page 1 PT: Um manual em seu idioma pode ser encontrado na Internet: PL: Instrukcję w swoim języku możesz znaleźć na stronie: SWE: En handbok på ditt språk finns på Internet: NL: Een handleiding in uw taal vindt u op internet: www.easypix.info/download-manuals/download/pulseoximeter/...
  • Page 2: Table Of Contents

    Content Disclaimer ....................2 Retaining instructions ................2 Explanation of safety warnings ..............3 Product introduction .................. 4 Intended use ....................4 Restrictions ....................4 Safety instructions..................5 Storage environment .................. 7 Product elements ..................8 Technical data..................... 8 Description of the product ................. 9 Function description ................
  • Page 3: Disclaimer

    Furthermore, Easypix reserves the right to revise this publication at any time without incurring an obligation to notify any person of the revision. Easypix is not responsible or liable for misuse of the information that is contained herein. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us.
  • Page 4: Explanation Of Safety Warnings

    instructions and follows them. Keep all safety information and instructions for future reference and pass them on to subsequent users of the product. The manufacturer is not liable for cases of material damage or personal injury caused by incorrect handling or non-compliance with the safety instructions. Explanation of safety warnings Warning indicates ahazard with a medium level of risk which, if notavoided, could result in serious injury.
  • Page 5: Product Introduction

    Product introduction A Pulse Oximeter is a common device used to check oxygen saturation (SpO²) and pulse rate. It is a compact, reliable and durable physiological monitoring device featuring an OLED display and powered by batteries (not included). Intended use The Pulse Oximeter is reusable device and is intended for spot checking the pulse oxygen saturation and pulse rate of adults.
  • Page 6: Safety Instructions

    If you experience any discomfort in use, please stop immediately and seek medical help. • When using the Pulse Oximeter the user should pay attention to, and guarantee safety of the patient being measured. • The Pulse Oximeter does not feature an alarm function. It should not be used for continuous monitoring for an extended period.
  • Page 7 The device should not be modified, repaired or serviced in any way by the end user. EXPLOSION HAZARD! Do not use the Pulse Oximeter in the presence of flammable anesthetics, explosive substances, vapors or liquids. • Ensure the device is always clean and free from dirt before use.
  • Page 8: Storage Environment

    Portable and mobile radio frequency communication equipment can affect the normal use of the pulse oximeter. Storage environment • The Pulse Oximeter should not be close to or stored with other equipment. • Always store the device and small parts such as batteries out of the reach of children.
  • Page 9: Product Elements

    Product elements • Pulse Oximeter • Lanyard • User manual EN/DE Technical data • OLED display • SpO²: Measurement range: 35-100% Accuracy: ±2% (80%-100%); ±3% (70%-79%) • Pulse rate: Measurement range: 25-250bpm Accuracy: ±2bpm Pulse rate accuracy has passed proving and comparison with SpO²...
  • Page 10: Description Of The Product

    Description of the product 1. SpO² indicator 2. Power/function button 3. SpO² value 4. Plethysmogram wave 5. Buzzer indicator 6. Battery status 7. PI indicating (Perfusion index) 8. Pulse rate indicator 9. Pulse rate value...
  • Page 11: Function Description

    Oxygen saturation indicates the percentage of haemoglobin in the arterial blood that is loaded with oxygen. The Pulse Oximeter uses two light beams of different wavelengths for measurement. These light beams strike the inserted finger inside the housing and are put in relation to each other during measurement.
  • Page 12 3. Press the power / function button on the front panel to switch on the device. Keep the finger and device still with as little movement as possible and allow the device to take a measurement. 4. The readings will be displayed on the OLED screen a moment later as shown in Figure 4.
  • Page 13 Obstruction of blood flow during NIBP measurements may adversely affect the reading of the SpO² value. • Do not use the Pulse Oximeter to measure patients whose pulse rate is lower than 30bpm, as this may cause incorrect results. •...
  • Page 14 Rotate the display To rotate the display for convenient reading, when the result has been displayed on the screen, short press the “POWER/FUNCTION” button once. Turn off the buzzer Short press the “Power/function” button four times, the display direction will be restored to the previous state. The buzzer will be turned off.
  • Page 15 Signal display When the signal received by the device is too weak, small lines will be displayed on the screen. Auto switch off The product will switch off automatically after 10 seconds of no signal being detected.
  • Page 16: Lanyard Placement

    Lanyard placement 1. Thread the thinner end of the lanyard through the hole as shown in the picture. Note: There is also the option to use either side. 2. Thread the thicker end of the lace through the threaded end before pulling it tightly.
  • Page 17: Troubleshooting

    Troubleshooting Trouble Possible reason Solution The SpO² and PR 1. The finger is not properly 1. Reposition the finger can’t be displayed positioned. properly and try again. normally and 2. The patient’s SpO² is too 2. Attend a doctor for a the value low to be detected.
  • Page 18: Cleaning And Disinfection

    Cleaning and disinfection Cleaning Clean the product with cotton or damp soft cloth. After cleaning, wipe dry and allow to full air dry. Disinfection The recommended disinfectants include: ethanol 70%, isopropanol 70%, glutaraldehyde (2%) solution disinfectants. 1. Clean the product as instructed above. 2.
  • Page 19: Disposal

    Disposal Dispose of packaging For disposal, separate packaging into different types. Cardboard and board must be disposed of as paper and foil must be recycled. Disposal of Waste Electrical and Electronic Equipment and/or Battery by users in private households in the European Union. This symbol on the product or on the packaging indicates that this cannot be disposed of as a household waste.
  • Page 20: Symbol Meaning

    Symbol meaning Symbol Meaning “CAUTION”! Please refer to the operation manual. Type BF Equipment. The product does not contain an alarm function. When the end-user wishes to discard this product, it must be sent to separate collection facilities for recovery and recycling.
  • Page 21 Shanghai Berry Electronic Tech Co., Ltd. Unit 104, 1st Floor, 7th Building, No.1188 Lianhang Road, Minhang District, Shanghai, China 201112 Prolinx GmbH Brehmstr. 56, 40239 Düsseldorf, Germany...
  • Page 22: Declaration Of Conformity

    Declaration of conformity For the product Pulse Oximeter We hereby confirm that it meets the basic requirements laid down in Council Directive (1999/5/EC). This declaration is based on the full compliance of that product with the following European standards: CE0123 (TÜV) This explanation is given for the manufacturer / importer...