  • Page 1 CloudMinds AI Raman Spectrometer MR-5S User Guide Copyright © 2018 CloudMinds, Inc...
  • Page 3: Table Of Contents

    Contents Introduction ......................1 Warning ....................... 1 Opening the box ....................2 List of parts ....................... 2 External view of device ..................3 Accessories ...................... 3 Internal view of carrying case ................4 Attaching detection probes ................4 Charging the device ..................5 Understanding the device ..................
  • Page 4 Database ......................18 Logging in to a database account ..............18 Changing your login(cloud database detection service) password ....19 Downloading databases .................. 19 Syncing databases ..................19 Browsing databases ..................20 Searching databases ..................20 Updating offline detection databases ............... 20 Resetting the offline detection database ............
  • Page 5 Routine calibration ..................26 Safe use ......................26 Medical device safety ..................26 Cleaning the device ..................26 Driving safety ....................27 Battery care ....................27 Avoid condensation ..................27 For further assistance ..................28...
  • Page 8: Introduction

    Introduction Thank you for choosing CloudMinds’s AI Raman spectrometer XI MR-5S. This handbook will help you understand the initial settings and basic functionality of the XI MR-5S as well as necessary safety information. Before reading the contents of this manual, please note: The functions described in this manual are those featured on your device as originally delivered from the factory.
  • Page 9: Opening The Box

    Opening the box List of parts The box contains the following items: MR-5S • Protective case (already attached to device) • Charger • USB Type-C data cable • Card ejector pin • Standard detection probe (already attached to device) • Solid/powder detection cap (already attached to device) •...
  • Page 10: External View Of Device

    External view of device Accessories...
  • Page 11: Internal View Of Carrying Case

    Internal view of carrying case Attaching detection probes Your device is equipped with two detection probes. Attach and remove the device’s detection probes in a clean, dry environment. Prevent dust, pollutants, water or other liquids from entering the device, which can cause electrical faults or influence the results of the laser detection.
  • Page 12: Charging The Device

    Charging the device Charge the XI MR-5S before use. The device requires 3.5 hours to fully charge. Connect the data cable to the charger. Plug the data cable into the USB Type C port at the bottom of the device. The device screen will automatically light up to show that it is charging.
  • Page 13: Using The Laser

    When you are in the personal domain, is displayed in the top left corner. • When you are in the detection domain, is displayed in the top left corner. • Current Screen Location Tap to Switch to personal domain Using the laser Before you use the XI MR-5S laser, you must undergo training to understand the operating principles, performance parameters and safety specifications for the...
  • Page 14: Connecting To A Network

    The distance between the center of the laser lens and the laser focal spot is approximately 10mm. Connecting to a network This device can conduct online detection via mobile networks and wireless local area networks. It can also be used offline. Connecting to a mobile network If you have inserted a SIM card into the device, you may choose to use a mobile network to connect to the cloud detection service.
  • Page 15: Environmental Requirements

    detection. The offline detection mode is the same as detection when there is no network connection. Environmental requirements The penetrability of the laser varies depending on different materials. Often, different detection accessories need to be used depending on the type of container that holds the sample.
  • Page 16 If the sample container is a thin and transparent bag such as a reagent bag, you • must attach the solid/powder detection cap and position the detection cap flush against the outside of the bag. This way, the laser focal spot will be on the inside of the bag.
  • Page 17 Remove the accessory attached to the laser emitter window and attach the • extended detection probe. Remove the lid of the container and place the probe inside to carry out detection. If the sample has heat sensitive properties, the extended detection probe cannot be used. Transfer the sample into a thin-walled container to carry out detection.
  • Page 18 Unpackaged powder samples If the sample to be tested is unpackaged powder, such as powder on a concrete floor, choose one of the following methods of detection: If conditions allow, transfer a suitable amount of the powder into a reagent bag and •...
  • Page 19 Unpackaged liquid samples If the liquid is sufficiently safe, collect the liquid within a quartz reagent bottle, remove the accessory attached to the device’s laser emitter window, and use one of the following methods of detection: Place the laser emitter window directly against the outside of the container. •...
  • Page 20: Starting Detection

    Scanning thin or loose solid samples If the solid sample to be scanned is fibrous or thinly spread (such as cotton, plastic netting, or paste), collect more of the sample, press it into a tight ball and place inside a reagent bag, then enable the solid/powder detection cap to touch the reagent bag to carry out detection.
  • Page 21 Place a small amount of the substance to be identified (<300µl or 5 drops for liquids, • <300mg for solids) into a reagent bottle or bag. Do not seal the container. • Do not place the substance to be identified on paper or other cellulose materials •...
  • Page 22 Detection successful, identification unsuccessful: The device shows the • spectrogram for the sample but is unable to find a match in the spectral database. You can name the unknown substance and add it to your personal database. You can also add it to the expansion database, if you have permission. See Adding new substances on page 21 for how to add the substance.
  • Page 23 Offline detection Your device may only use offline detection in the following circumstances: The device is logged in to an account, and you have manually chosen offline • detection. The device is logged in to an account, but the network connection has been lost. •...
  • Page 24: Exporting Records

    substance. Detection unsuccessful: The device failed to obtain a spectrogram. There • was no valid information available Uploading offline detection records Not all offline detection results can be uploaded to the cloud database. The way the device saves the offline detection results depends on the offline mode and account login status.
  • Page 25: Database

    Companies may customize the names and classifications of hazardous and safe goods using the Raman detection management system. Please follow your company's rules and regulations regarding the handling of hazardous samples. Do not arbitrarily dump, discard, ignite, compress or knock the sample.
  • Page 26: Changing Your Login(Cloud Database Detection Service) Password

    If you tap escape log in English > escape log in from the login screen, you will be unable to use the cloud detection service. When turning the device on for the first time, it will force the user to log in to an account via the detection domain, connect to a network, and download the calibration files and the spectral database to the device.
  • Page 27: Browsing Databases

    Browsing databases You can browse information on all the substances you are able to detect in your current mode. The information is split across the basic local database, expansion database, personal database, and logged-out self-created database. > spectral library You may: Swipe up and down the database list to browse the data in the database.
  • Page 28: Adding New Substances

    database. After resetting, the device will resynchronize the offline detection database from the cloud. > offline analysis Tap Reset Offline Database Tap confirm Adding new substances You can use the device to add unknown substances to a database. Adding new substances to your personal database You can add new substances that have been identified to your personal database for future reference.
  • Page 29: Detection Settings

    > spectral library > local spectral library to view the newly added substance information. When there is a network connection, the data in the local personal database can be synched to the cloud personal database. Moving data to the extension database Data in the local personal database can be moved to the local expansion database and then synched to the cloud expansion database.
  • Page 30: Calibrating The Device

    Updating the software CloudMinds periodically updates the device's software system. You can manually check if there is an updated software system available for download and installation. Before checking for new versions, make sure the device is connected to a network.
  • Page 31: Enabling Sound And Vibration Alerts

    1. The cloud databases created by your company are the basic database, expansion database and personal database. 2: The public cloud databases created by CloudMinds contain the basic database and personal database. If you use a cloud detection platform created by your company, contact your system administrator to obtain an account and password.
  • Page 32: Device Specifications

    password. Device specifications Size 159mm x 78.9mm x 27mm Weight 410g Battery capacity 5700mAh Laser power 100-500mW, adjustable Laser wavelength 785nm Detection range 200-1,800cm Resolution 8-11cm Detection time < 3s (ethanol) Databases Cloud: Basic cloud database, expansion database, personal database Device: Basic local database, expansion database, personal database, logged-out self-created databases Both cloud and local expansion and personal databases...
  • Page 33: Care And Maintenance

    Care and maintenance Routine calibration Calibrate the device at least once a day to ensure that it remains in good working order. See Calibrating the device on page 23 for the calibration method. Safe use Keep the device and accessories out of the reach of children. •...
  • Page 34: Driving Safety

    Do not wipe the device case with a damp cloth to avoid causing moisture and faults • in the device. Do not use chemical products, detergents or water to clean the device. • Do not store the device in very high or low temperature to avoid damaging the •...