2.2.1.18 User Pattern Effect bulk dump
This message sets the User Pattern Voice Effect block (see Tables <4-1> and <4-7>).
2.2.1.19 User Pattern Multi Part bulk dump
This message sets the User Pattern Voice Multi Part block (see Tables <4-1> and <4-9>).
2.2.1.20 User Pattern Rhythm Step Seq bulk dump
This message sets the User Pattern Rhythm Step Seq block (see Tables <4-1> and <4-11>).
2.2.1.21 User Song bulk dump
This message sets the User Song block (see Tables <4-1>, <4-12> and <4-13>).
2.2.2 DX bulk dump
F0H
Exclusive status
11110000
01000011
43H
YAMAHA ID
0000nnnn
0NH
N:Device Number
0ttttttt
TTH
Format No.
0sssssss
SSH
ByteCountMSB
0ttttttt
TTH
ByteCountLSB
VVH
Data
0vvvvvvv
:
:
KKH
Check-sum
0kkkkkkk
F7H
End of Exclusive
11110111
Address and Byte Count are given in tables <3-n>. Byte Count is indicated by the total size
of the Data in tables <4-n>.
Bulk dump is received when the beginning of the block is specified in "Address."
"Block" indicates the unit of the data string that is indicated in tables<3-n> as "Total size."
Check sum is the value that produces a lower 7 bits of 0 when the DATA, and the Check-sum
itself are added.
2.2.2.1 VCED bulk dump
This message sets the VCED block (see Table <2-1> and <2-2>).
2.2.2.2 ACED bulk dump
This message sets the ACED block (see Table <2-1> and <2-3>).
2.2.2.3 VMEM bulk dump
This message sets the VMEM block (see Table <3-1> and <3-2>).
2.2.2.4 AMEM bulk dump
This message sets the AMEM block (see Table <3-1> and <3-3>).
<1-1>
Parameter Base Address
MODEL ID = 62
Parameter
(H)
System
00
Current Voice
10
10
10
10
10
10
User Voice ( Common1 )
20
:
20
User Voice ( Common2 )
21
:
21
User Voice ( FreeEG )
30
:
:
:
31
:
3F
User Voice ( Scene-1 )
40
:
User Voice ( Scene-2 )
41
:
User Voice ( Step Seq )
50
:
(*1) The order of transmitting Current Voice Bulk
Current Voice Scene 1
Current Voice Scene 2
Current Voice Common 2
Current Voice Common 1
The others can be transmitted in free order.
Address
Description
(M)
(L)
00
00
System2
00
00
Current Voice Common 1
01
00
Current Voice Common 2
02
00
Current Voice FreeEG
03
00
Current Voice Scene 1
04
00
Current Voice Scene 2
40
00
Current Voice Step Seq Pattern
00
00
User Pattern Voice ( Common1 ) 1
:
:
:
7F
00
User Pattern Voice ( Common1 ) 128
00
00
User Pattern Voice ( Common2 ) 1
:
:
:
7F
00
User Pattern Voice ( Common2 ) 128
00
00
User Pattern Voice ( FreeEG ) 1
10
00
User Pattern Voice ( FreeEG ) 2
20
00
User Pattern Voice ( FreeEG ) 3
:
:
:
00
00
User Pattern Voice ( FreeEG ) 9
:
:
:
70
00
User Pattern Voice ( FreeEG ) 128
00
00
User Pattern Voice Scene-1 1
:
:
:
7F
00
User Pattern Voice Scene-1 128
00
00
User Pattern Voice Scene-2 1
:
:
:
7F
00
User Pattern Voice Scene-2 128
00
00
User Pattern Voice Step Seq 1
:
:
:
7F
00
User Pattern Voice Step Seq 128
3. Realtime Messages
3.1 Active Sensing
FEH
11111110
This is transmitted by 200msec.
After FE is received one time, if the MIDI signal does not come within 400 msec, DX200 will act
the same as when ALL SOUND OFF, ALL NOTE OFF, and RESET ALL CONTROLLERS are
received, and return to the condition where has not been received once.
3.2 Timing Clock
F8H
11111000
ON/OFF of the transmitting and receiving can be set.
3.3 Start
FAH
11111010
ON/OFF of the transmitting and receiving can be set.
3.4 Continue
FBH
11111011
ON/OFF of the transmitting and receiving can be set.
3.5 Stop
FCH
11111100
ON/OFF of the transmitting and receiving can be set.
4. System Common Messages
4.1 Song Position Pointer
11110010
F2H
0vvvvvvv
SONG POSITION LSB
0vvvvvvv
SONG POSITION MSB
ON/OFF of the transmitting and receiving can be set.
(*1)
Appendix