Download Print this page

Rentokil Vertex GeyserJet Series Manual page 3

Advertisement

FOUNTAIN CONTROL PANEL
Warning - The fountain control panel must be installed by licensed electrician in accordance with article
682 of national electrical code.
Panel location is above any and all possible high water levels. Submergence of panel poses serious risk of electrical shock and
damage of fountain system. Failure may result in potentially hazardous conditions and/or failure of electrical inspection.
Consult authorities having jurisdiction (ahj) for specific local codes/restrictions. Vertex Aquatic Solutions accepts/assumes no
responsibility for installations not in accordance with local and/or national electrical codes.
SCOPE OF WORK - ELECTRICIAN
1. Mount NEMA 3R panel enclosure in
accordance with NEC 682 following
any additional local codes and/or
restrictions that exist.
2. Trench and bury sufficiently sized
conduit(s) from fountain panel to
water's edge, extending conduit(s)
far enough into water to ensure no
submersible cable is exposed should
low water conditions arise.
3. Bring incoming power from power
source into the fountain panel.
Incoming voltage must match with
specifications of fountain panel
or failure will result, damaging the
system and voiding the warranty.
4. Pull submersible cable(s) from
fountain through conduit to control
panel and perform final connections
See Fountain Owner's Manual for
details on installing the fountain
in your lake.
IMPORTANT NOTES
Do not operate fountain and lights until
fountain installation has been completed
and lights are fully submerged.
Operating light(s) out of water will result
in damage to bulb(s) and lens(es),
voiding manufacturer's warranty.
Connect only 120V to light(s)
Higher voltage will result in immediate
damage or failure of bulb(s).
Drawings are for illustration only and not to scale. Installation of fountain equipment shall be in accordance with manufacturers specifications.
2100 NW 33rd St • Pompano Beach, FL 33069 • 844.432.4303 • vertexaquaticsolutions.com
Fountain Install

Advertisement

loading