Dimensional spacing of the mounting holes for the modules is shown in Figure 2.
To properly install please do not exert any bending or twisting torque to the module enclosure.
Ensure that the module's mounting points are co-planar within ±1 mm. If the actual mounting
location is out-of-plane, use spacers to bring all four mounting locations within plane to ±1mm.
To ensure proper vibration performance, all mounting points should be used for the PBLH™
modules. These modules have been tested to meet the following specifications:
If more severe vibration performance is anticipated, consider the use of isolators to provide
damping.

Electrical

3.2.
To avoid arcing, the energy storage module should be in a discharged
state and the system power disconnected during installation. The
module is shipped discharged and with a shorting wire. The shorting
wire should be removed prior to installation of electrical connections.
7520 Mission Valley Road ● San Diego, CA 92108-4400 ● USA ● Tel: 619.398.9700 ● Fax: 619.398.9777 ● www.tecategroup.com
9101380000.C.DOCX
 
Figure 2: PBLH™ Mounting Hole Locations
Shock
IEC-60068-2-27, IEC-60601-1-1
Vibration
IEC=60068-2-6
Mounting points: (4x)
M4x8 T20 drive screws
Maximum torque: 1.13 Nm