PRIOR-TO FIELD WORK

• Access to the Sentryx website is required to complete this
installation. If you do not have a user account or cannot log in, please
contact your site administrator. [Alerts from the Sentryx platform
will be provided for (a) coverage strength feedback in the "Field
Work" section and (b) "success" in Section 36. In order to receive
alerts, you need to create a Sentryx account (with current email
address and cell number provided), select email and/or text alerts,
and bring an electronic device to receive these alerts into the field.]
• Before installation, visit each potential site and verify 4G LTE CAT
M1 coverage. Reference the Mueller Cellular Signal Strength guide
(F14334).

FIELD WORK

For Retrofit Kit
• Signal Strength:
– Prior to disassembly of installed hydrant, confirm cell coverage at
site of installation.
– Hold the new bonnet near the same height and location of
installation.
– Place the commissioning tool close to the bonnet, approximately
1/4˝ away, above ˝M˝ on the seal plate flange, while keeping away
from iron parts. (Reference to the right ).
– Move the commissioning tool up along the curve of the bonnet
keeping it approximately 1/4˝ away from the surface. This action
will cause the bonnet to awaken and search for a connection.
ɥ If the bonnet does not establish a connection (i.e. no Sentryx
alert is provided within 5 minutes), select a different location.
– Once a connection is established, the Sentryx platform will
send out an email and/or text message (Depending on initial
configuration) displaying the signal strength. See Appendix A.
ɥ If message indicates a weak signal, select a different location.
ɥ If message indicates a strong signal, proceed through
instructions below.
Note: Caution: Changes or modifications not expressly approved by Mueller Systems, LLC could void the user's authority to operate the equipment. This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
SOFTWARE ENABLED
®
CAUTION
COMPLY WITH ALL REQUIRED INDUSTRY, SITE, STATE, AND
FEDERAL SAFETY REQUIREMENTS
DO NOT DROP NEW HYDRANT LOWER STEM OR NEW
BONNET ASSEMBLY. DAMAGE MAY OCCUR.
THE ANTENNA ON THE STEM CAN BE DAMAGED BY A
FORCEFUL IMPACT FROM A SEAT WRENCH – UTILIZE CARE.
SENTRYX SOFTWARE ENABLED SUPER CENTURION
IS DESIGNED TO WORK WITH MUELLER OEM PARTS ONLY.
AVOID BACKFILLING OVER EXPOSED BONNET AS DAMAGE
TO PAINT MAY OCCUR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SENTRYX SUPER CENTURION and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mueller SENTRYX SUPER CENTURION

  • Page 1 Note: Caution: Changes or modifications not expressly approved by Mueller Systems, LLC could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
  • Page 2 Sentryx software enabled Super Centurion. However, the bonnet will already be installed on the • Hard hat hydrant. Please reference the Mueller Cellular Signal Strength • Safety shoes guide (F14334) for suggestions on how this can be accomplished.
  • Page 3 (Reference AWWA M17). Once installation is complete, follow steps 37-40 below. CAUTION MUELLER CO. RECOMMENDS FOLLOWING AWWA M-17 MANUAL FOR INSTALLATION, FIELD TESTING AND MAINTENANCE OF FIRE HYDRANTS. Confirm the hydrant is de-pressurized as described above.
  • Page 4 Unscrew lower valve nut and remove. 16. Reassemble main valve assembly to new lower stem (Reverse steps) with newly provided brass lower valve nut and tighten to 90-115 ft-lbs. 12. Remove lock washer, stem seal, lower valve plate, main valve, seat ring and upper valve plate.
  • Page 5 25. Remove the plastic plug from top of the new bonnet assembly taking care of the hold down washer and bonnet o-ring. 19. Inspect and lubricate with grease top and bottom seat ring o-rings (replace if necessary). Mueller Co. recommends the use of Thred Gard Anti-Seize on threads. ®...
  • Page 6 26. Place the new bonnet assembly on top of the 29. Reassemble operating nut, anti-friction washer (on top upper stem, slide it down to top of upper barrel, thrust collar of operating nut), bonnet o-ring, hold down and hand tighten bolts (8). Remove brass sleeve. washer, and hold down nut (hand-tighten to secure in place).
  • Page 7 (Necessary for the stem to communicate with the bonnet) 33. Pour 1 bottle of Mueller hydrant lubricant into oil reservoir until the bottle is empty or the oil is level with inner oil plug hole. [Do not pour oil outside the oil reservoir].
  • Page 8 For customer support or to report any product issues, please call 1.800.423.1323 or email techservices@muellerwp.com. Mueller refers to one or more of Mueller Water Products, Inc. a Delaware corporation (“MWP”), and its subsidiaries. MWP and each of its subsidiaries are legally separate and independent entities when providing products and services.