Technical Specifications - Hella 8ES 004 417-081 Operating Instructions Manual

Battery charger 7a
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
EN
ENGLISH

TECHNICAL SPECIFICATIONS

Charger model:
Model number:
Rated Voltage AC:
Charging voltage:
Start voltage:
Charging current:
Current, mains:
Back current drain: *
Ripple: **
19
Ambient temperature:
Charger type:
Battery types:
Battery capacity:
Dimensions:
Insulation class:
Weight:
*) Back current drain is the current that drains the battery if the charger is not connected to the mains.
**) The quality of the charging voltage and charging current is very important. A high current ripple heats up the battery which has an aging
eff ect on the positive electrode.
7,0 A
8PE 004 417-081
220–240VAC, 50–60Hz
NORMAL 14.4V, AGM
14.7V, RECOND 15.8V, SUPPLY 13.6V
2,0V
7.2A max.
1.2A rms (at full charging current)
< 1Ah/month
<4%
-20°C bis +50°C, output power is reduced automatically at high temperatures
8-step, fully automatic charging cycle
All types of 12V lead-acid batteries (WET, MF, Ca/Ca, AGM and GEL)
14―150Ah up to 225Ah for maintenance
191 x 89 x 48mm (L x W x H)
IP65
0.8kg