Connecting the Receiver Unit
Each Channel output relay provides an isolated changeover Contact. Outputs 2 to 4 Connections are
Common (COM) and Normally Open (NO) which close together when activated. Output 1 has an addi-
tional Normally Closed (NC)
The action of the relay outputs is set by the Option link setting Jumper. A link is made / removed by the
small shorting link 'cap' placed over the pin header.
LINCOLN-4S1 Receiver Circuit board
Link Postion Controls Outputs
Fitted 1 - - 2=
Fitted 1
2= Momentary
Momentary
Fitted 2 - - 3=
Fitted 2
3= Latching
Latching
Not Fitted = FlipFlop
Not Fitted =
FlipFlop
Momentary : The relay is activated for as long as transmitter button pressed.
Latching
: The relay toggles between On / Off each button press.
FlipFlop
: Relays 1 & 2 and 3 & 4 operate in pairs.
When button 1 is pressed relay 1 switches on, Relay 2 Switches off
When button 2 is pressed relay 2 switches on, Relay 1 Switches off
Relay 3 & 4 operate in the same manor to Transmitter buttons 3 & 4.
Learning a New Transmitter Keyfob
Briefly Press the "Learn Switch" on the receiver PCB, the receiver LED will illuminate.
Press any transmitter button once, the receiver LED will flash 3 times.
This transmitter will operate the system.
Erasing Existing Transmitters
Press and hold the receiver "Learn Switch", the receiver LED illuminates.
When the LED extinguishes (5-10 seconds) the Receiver is erased.
NOTE: You can not erase individual Tx encoders
NOTE: maximum of 45 button pairings per receiver