Level 1 Repair
6-4. RF Calibration
6-1-1. Required items in order to calibrate RF
Installation program: RF Calibration Program
- Daseul_Launcher_vx.x.xx.exe
- Daseul_CAL_ALL_Runtime_x.x.xxx.x.CAB
- Model File (SM-N910F_OPEN_CALIBRATION_VER_x.x.xxx.xx.CAB)
※ It is required to use the latest program.
SM-G360M Mobile Phone
E3632A Power Supply
JIG BOX (GH81-11888A)
• Adapter (GH81-11888K)
• 4 Port Divider (GH81-11962A)
• 1.35Φ RF Cable (GH81-11962D, 2ea)
※ Setting
1.35 Φ
RF Cable
Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsung's written authorization is strictly prohibited.
JIG BOX
IF Cable
4 Port Divider
50 Ω Termination
Ÿ R&S CMW500
Ÿ GPIB Cable (2ea)
Ÿ IF Cable (GH81-10958A)
Ÿ UART Serial Cable
Ÿ 50 Ω Termination (GH81-11962E, 2ea)
Ÿ Divider RF Cable (GH81-11962B)
Serial Cable
E3632A
Power Supply
Divider
RF Cable
6-19
GPIB Cable
(2ea)
CMW 500