ACOPOWER Midas Y Series User Manual page 21

Mppt solar charge controller
Table of Contents

Advertisement

The following rules must be observed when modifying the parameter values in
User for lead-acid battery.
Ⅰ. Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging
Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect
Charging Voltage.
Ⅱ. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
Ⅲ. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging
Limit Voltage.
Ⅳ. Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥
Discharging Limit Voltage.
Ⅴ. Boost Reconnect Charging voltage >Low Voltage Reconnect Voltage.
Lithium battery parameters
The parameters are in 12V system at 25 ºC, please double the values in 24V system.
Voltage
Over Voltage Disconnect Voltage
Charging Limit Voltage
Over Voltage Reconnect Voltage
Equalize Charging Voltage
Boost Charging Voltage
Float Charging Voltage
Boost Reconnect Charging Voltage
Low Voltage Reconnect Voltage
Under Voltage Warning
Reconnect Voltage
Under Voltage Warning Voltage
Low Voltage Disconnect Voltage
Discharging Limit Voltage
The following rules must be observed when modifying the parameter values in User
for lithium battery.
Battery type
LiFePO4
Li(NiCoMn)O2
15.6V
14.6V
14.7V
14.5V
14.5V
13.8V
13.2V
12.8V
12.8V
12.0V
11.1V
10.6V
18
13.5V
12.6V
12.7V
9~17V
12.5V
12.5V
9~17V
12.2V
12.1V
9~17V
10.5V
9~17V
11.0V
9~17V
10.5V
9~17V
9.3V
9~17V
9.3V
9~17V
User
9~17V
9~17V
9~17V
9~17V

Advertisement

Table of Contents
loading

This manual is also suitable for:

My20My30My40