Download Print this page

LCJ CAPTEURS CV7-BG Manual page 2

Ultra lightweight & compact wind sensor option

Advertisement

Available languages

Available languages

additif CV7-BG.doc
CV7-BG Option
Connect the 12V DC (10 to 14) supply. Blue - / Brown +
Connect the cable of the CV7 sensor correctly connecting the color. (yellow wire not connected)
Power up the instrument then follow the procedure in the "User calibration" of display
user manual
Connect the display receiver equipment to the NMEA connector:
- for the COM(1) port of an RS232 computer
connect Rx terminal 2 of COM1
to the AUX connector block terminal A
connect 0V terminal 5 of COM1
to the ALIM (SUPPLY) connector block terminal 0V
if necessary, connect terminals 6 and 7 of COM1 together.
- for a floating RS422 standardised NMEA 183 input
Make sure in advance that none of the receiver inputs is attached to 0 Volts, otherwise use the RS232 type connection.
connect terminal A of the AUX connector block to +Ve ( or In +) or A of the NMEA display
connect terminal B of the AUX connector block to -Ve ( or In -) or B of the NMEA display
Violette
Black
Orange
BG
Blue
Green
Red
LCJ CAPTEURS ZA Le Chêne Ferré 44120 VERTOU – Tel 33.(0)2.40.05.08.55 – lcjcapteurs@lcjcapteurs.com
L=131mm
COM1 type connector - Soldering side
W=58mm
H=37mm
15/07/2008
1
2
3
4
5
6
7
8
9
PC SUBD 9 terminal
12 V Red
0 V Blue
Green
Out+NMEA
Out-NMEA

Advertisement

loading