PFAFF silberblau COLUMBUS McKINNON SW K LAMBDA BGV C1 Translated Operating Instructions

PFAFF silberblau COLUMBUS McKINNON SW K LAMBDA BGV C1 Translated Operating Instructions

Console mounted wire rope winch
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

D
Original Betriebsanleitung
GB
Translated Operating Instructions
F
Traduit Mode d'emploi
Nr. 040034472_Ed.-03.2013
Ref.-Nr.
Type (Basismodell)
Mat. Nr.
Prüf.-Nr.
Baujahr
Hublast
04.04.014_PDF_14.01.2013 / UD
Ref.-No.
Type (Base model)
Mat. no.
Ser.-No.
Year of manufacture
Capacity
Konsolenseilwinde
Console mounted wire rope winch
Treuil à fixer sur une console
SW K LAMBDA BGV C1
für Bühnen und Studios
for stages and studios
pour des scènes et des studios
www.pfaff-silberblau.com
No. de réf.
Type (Modèle de base)
Numéro d'article
No. de série
Année de construction
Capacité

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COLUMBUS McKINNON SW K LAMBDA BGV C1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PFAFF silberblau COLUMBUS McKINNON SW K LAMBDA BGV C1

  • Page 1 Original Betriebsanleitung Translated Operating Instructions Traduit Mode d’emploi Nr. 040034472_Ed.-03.2013 Konsolenseilwinde Console mounted wire rope winch Treuil à fixer sur une console SW K LAMBDA BGV C1 für Bühnen und Studios for stages and studios pour des scènes et des studios www.pfaff-silberblau.com Ref.-Nr.
  • Page 2 Seilwinde LAMBDA -BGV C1 Wire Rope Winch LAMBDA BGV C1 04.04.014 Treuil LAMBDA BGV C1 rope pressure drum 30.5 Ø13 M12, min. 8.8 Type 030272015 030272017 030272018 030272019 [mm] [mm] [mm] [mm] Bildliche Darstellung unverbindlich! Graphic representation not binding! Représentation graphique sans engagement! 2 / 2 technische Änderungen vorbehalten design changes under reserve...
  • Page 3: Bestimmungsgemäße Verwendung

    Seilwinde >LAMBDA< BGV C1 für Bühnen und Studios 04.04.014 Deutsch Vor Inbetriebnahme die Betriebsanleitung aufmerksam lesen! Sicherheitshinweise beachten! Dokument aufbewahren! Bestimmungsgemäße Verwendung Die Seilwinde >LAMBDA< mit Stirnradgetriebe ist eine handbetriebene Winde für Hängevorrichtungen in Bühnen und Studios gem. UVV BGV C1 zum Heben und Senken von Lasten. Nicht geeignet für Verwendung in explosionsgefährdeten Räumen.
  • Page 4: Technische Daten

    Seilwinde >LAMBDA< BGV C1 für Bühnen und Studios 04.04.014 Deutsch Die Winde Tägliche Prüfungen Tragfähigkeit entspr. Typenschild nicht überschreiten. Bremsenfunktion  Vor Inbetriebnahme durch ermächtigten Sachverständigen prüfen: Zustand des Seiles und des  Hubgerät  Lastaufnahmemittel Tragkonstruktion  Tragkonstruktion  Tragmittel ...
  • Page 5: Bedienung

    Seilwinde >LAMBDA< BGV C1 für Bühnen und Studios 04.04.014 Deutsch Mechanische Befestigung: Schrauben M 12 Güteklasse min. 8.8 Anzahl der Schrauben Anziehmoment 70 Nm Einbaulagen Drahtseileinlauf Die Seilwinde kann in verschiedenen Lagen eingebaut werden. Auf Seileinlauf und Seilabgang achten! Seileinlauf Seileinlauf Drahtseilbefestigung Drahtseil unter Berücksichtigung des...
  • Page 6 Seilwinde >LAMBDA< BGV C1 für Bühnen und Studios 04.04.014 Deutsch Inspektions- und Wartungsanleitung Vor Inspektions- und Wartungsarbeiten ist die Winde durch geeignete Maßnahmen zu entlasten. Inspektionsintervalle Wartungs- und Inspektionsarbeiten täglich Sichtprüfung Seil - Haken ( Tragmittel ) bzw. Funktion der Winde vor jedem Gebrauch Bremsfunktion vierteljährlich...
  • Page 7: Regulations For The Prevention Of Accidents

    Wire rope winch >LAMBDA< BGV C1 for stages and studios 04.04.014 English Before taking into operation, please carefully read this operating instruction! Observe the safety instructions! File documentation! Destined use The wire rope winch >LAMBDA< with spur gear is a manually operated winch for suspension devices in stages and studios acc.
  • Page 8: Technical Data

    Wire rope winch >LAMBDA< BGV C1 for stages and studios 04.04.014 English The Winch Daily examinations: Do not exceed the capacity of name-plate.  brake functions Before taking into operation, a competent person must check:  condition of the rope and ...
  • Page 9: Mechanical Fixing

    Wire rope winch >LAMBDA< BGV C1 for stages and studios 04.04.014 English Mechanical Fixing: screws M 12 material grade min. 8.8 Number of screws Tightening torque [Nm] Mounting positions Wire rope direction Various rope paths can be applied subject to the mounting positions as shown.
  • Page 10: Inspection- And Maintenance Instructions

    Wire rope winch >LAMBDA< BGV C1 for stages and studios 04.04.014 English Inspection- and Maintenance Instructions Before carrying out inspection and maintenance works, unload the winch appropriately. Inspection Intervals Maintenance- Inspection Works daily Visual examination of rope-hook (carrying device). resp. Function of the winch.
  • Page 11: Usage Autorisé

    Treuil >LAMBDA< BGV C1 pour des scènes et des studios 04.04.014 Français Lire attentivement le mode d'emploi avant usage ! Observer les instructions de sécurité ! Conserver ces documents ! Usage autorisé Le treuil >LAMBDA< à engrenage droit est un treuil manuel pour des scènes et des studios selon BGV C1 qui sert à...
  • Page 12: Données Techniques

    Treuil >LAMBDA< BGV C1 pour des scènes et des studios 04.04.014 Français Le treuil Vérifications quotidiennes Ne pas dépasser la capacité selon le plaque caractéristique. le fonctionnement du frein  Avant usage, laisser vérifier par une personne compétente: l'état du câble et le moyen de ...
  • Page 13 Treuil >LAMBDA< BGV C1 pour des scènes et des studios 04.04.014 Français Fixation mécanique: M 12 classe de qualité min. 8.8 nombre de vis couples de serrage [Nm] Direction du câble Position de montage Les treuils peuvent être fixés dans des positions différentes.
  • Page 14 Treuil >LAMBDA< BGV C1 pour des scènes et des studios 04.04.014 Français Instructions d'inspection et de maintenance Instruction de sécurité Avant d’effectuer des travaux d’inspection et de maintenance, s’assurer que le treuil soit déchargé. Intervalles d’inspection Travaux d’inspection et de maintenance touis les jours Contrôle visuel du crochet et du câble (moyen de levage) Le fonctionnement du treuil...
  • Page 15: Eg-Konformitätserklärung

    EG-Konformitäts- EC-Declaration Déclaration "CE" erklärung of Conformity de Conformité im Sinne der EG-Maschi- as defined by EC Machinery conformément à la directive nenrichtlinie 2006/42/EG, Directive 2006/42/EC, "CE" relative aux machines Anhang II, Nr. 1A annex II, No. 1A 2006/42/CE, Annexe II No. 1A Hiermit erklären wir, dass Herewith we declare that the supplied model of Nous déclarons que le modèle...
  • Page 16 Alle Standorte finden Sie auf / All locations can be found at www.pfaff-silberblau.com COLUMBUS McKINNON Engineered Products GmbH Am Silberpark 2-8 86438 Kissing GERMANY Telefon +49 8233 2121-0 Telefax +49 8233 2121-805 info.kissing@cmco.eu www.cmco.eu/pfaff-silberblau Händler: Merchant / commerçant Firmenstempel/stamp/cachet de la maison Bei Inbetriebnahme Note name-plate data when taking Inscrire les données sur la plaque du...

Table of Contents