P A R A M E T R I C
E Q U A L I Z A T I O N
CENTER FREQUENCY
/
RANGE OF BOOST
CUT
T h e P 5 0 0 i s a 5 - b a n d p a r a m e t r i c e q u a l i z e r . I t s d e s i g n
a l l o w s t h e u s e r t o v a r y c e n t e r f r e q u e n c y , s e l e c t a " Q " o f 1 -
1 0 , a n d s e l e c t u p t o 1 8 d B o f b o o s t o r c u t .
Center frequencies range from 20 Hz to 20 KHz. The on-
board frequency jumper divides the frequency range into three
bands: 20 Hz to 200 Hz, 200 Hz to 2 KHz, and 2 KHz to 20 KHz.
Simply place the jumper in one of the three positions which cor-
responds with the frequency to be adjusted. The specific fre-
quency is then selected via the "frequency" potentiometer
"Q" d e t e r m i n e s t h e r a n g e o f f r e q u e n c i e s a f f e c t e d o n e i t h e r
s i d e o f t h e c e n t e r f r e q u e n c y . "Q " i s equal t o t he center f r e-
quency di vi ded by t he bandw i dt h. A s "Q " goes up, bandwi dt h
decreases. The P500's "Q" adjustment ranges from a narrow
bandwidth of 10 to a very broad bandwidth of 1.
Boost / Cut on the P500 is +/–18 dB. The rotary poten-
t i o m e t e r p r o v i d e s c o n t i n u o u s l y v a r i a b l e a d j u s t m e n t .
P 5 0 0 T U N I N G S E Q U E N C E
T he P500 i s desi gned t o be "set - up" or "t uned" w i th t he ai d
of a R e a l T i m e S p e c t r u m A n a l y z e r m e a s u r i n g a p i n k n o i s e s i g-
nal generated by the mobile audio system. The analyzer pro-
vides visual feedback when following the steps listed below.
R T A t h e s y s t e m a n d d e t e r m i n e p o i n t s o f a d j u s t m e n t . T u r n
t h e s y s t e m o f f a n d p l a c e e a c h o f t h e f r e q u e n c y r a n g e j u m p e r s
i n t o t h e i r c o r r e s p o n d i n g " f r e q u e n c y r a n g e " p o s i t i o n s .
P e r f o r m t h e f o l l o w i n g s t e p s p e r b a n d:
W i t h t h e s y s t e m p l a y i n g p i n k n o i s e , t u r n o n t h e
RTA and adjust pink noise SPL to 85 – 90 dB.
Turn the boost/cut control to +18 dB (full clockwise
rotation). This will show the present center frequen-
cy and "Q" settings on the analyzer.
Rotate frequency control to the frequency you wish to
adjust.
Adjust "Q" setting to match the width of the dip or
peak you are addressing.
Finally, adjust the gain control to achieve the desired
response curve.
•
•
•
•
•
•
•
"Q":
I N S T A L L E R
HIGH
A NARROW RANGE OF
(
FREQUENCIES
ON EITHER SIDE OF
)
THE CENTER FREQUENCY
ARE
.
AFFECTED BY EQUALIZATION
D
A T E INSTALLED
O
'
W N E R
S N A M E
"Q":
-
LOW
A WIDER RANGE OF FRE
(
QUENCIES
ON EITHER SIDE OF THE
A
:
D D R E S S
)
-
CENTER FREQUENCY
ARE AFFECT
.
ED BY EQUALIZATION
C
/ S
:
I T Y
T A T E
V
:
E H I C L E
X
P 5 0 0
T A N T
S E R I A L
MODES OF OPERATION:
:
I N P U T M O D E
B A L A N C E D L I N E
:
N O I S E G A T E
P500 ADJUSTMENTS
front "a"
FREQ.
Q ADJUST
+/– 18 dB
Freq. Range
20 – 200 Hz
200 – 2 KHz
2K – 20 KHz
system components
SOURCE
(
)
PROCESSOR
S
(
)
A M P L I F I E R
S
x t a n t t e c h n o l o g i e s
7 6 7 6 S
•
•
'
S
R E F E R E N C E
:
:
P
:
HONE
Z
:
I P
Y
:
E A R
#
(
)
C I R C L E S E T T I N G
4
2
C H A N N E L
C H A N N E L
:
E N A B L E
D I S A B L E
O N
D E F E A T
(
&
.
DRAW POSITION O F CONTROL
CIRCLE FREQ
front "b"
front "c"
rear "a"
FREQ.
FREQ.
FREQ.
Q ADJUST
Q ADJUST
Q ADJUST
+/– 18 dB
+/– 18 dB
+/– 18 dB
Freq. Range
Freq. Range
Freq. Range
20 – 200 Hz
20 – 200 Hz
20 – 200 Hz
200 – 2 KHz
200 – 2 KHz
200 – 2 KHz
2K – 20 KHz
2K – 20 KHz
2K – 20 KHz
#
S E R I A L
#
S E R I A L
#
S E R I A L
#
S E R I A L
#
S E R I A L
#
S E R I A L
•
•
•
•
•
•
4 6
S
P
, A
8 5 0 4 0 U S A
O U T H
T H
TREET
HOENIX
RIZONA
6 0 2 4 3 1 8 6 8 6
•
•
•
•
•
•
•
•
x t a n t t e c h n o l o g i e s
L O G
installer's reference
T
H I S DOCUMENT H A S B E E N C R A F T E D T O M A K E I N S T A L L A
,
T I O N
SYSTEM D E S I G N A N D TROUBLE
A N D E A S Y PROCESS
P L E METHOD O F D O C U M E N T A T I O N
I T I S I M P O R T A N T T H A T Y O U R E T A I N T H I S L O G
FOR YOUR RECORDS. O
M
,
A N U A L
Y O U W I L L F I N D T H E
O
N C E Y O U H A V E N O T A T E D T H E F I N A L SETTINGS F O R T H I S
P 5 0 0 ,
T R A N S F E R
R
L
. I
EFERENCE
OG
/
A N D
O R PROBLEMS M A Y B E REFERENCED T O T H I S LOG
I N S T A L L A T I O N
)
RANGE SELECTED
P500
REMOVE
rear "b"
Loosen allen head screws and lift-off cover. Do not remove
p r o t e c t i v e c o v e r i n g o n s t a i n l e s s s t e e l l i d u n t i l i n s t a l l a-
tion is com ple te .
TEMPORARILY MOUNT
FREQ.
The P500 is designed to be anchored through the four (4)
h o l e s l o c a t e d o n t h e c i r c u i t b o a r d / b a s e a s s e m b l y .
MARK WIRES FOR TERMINATION AND REMOVE
Determine wire lengths for Power, Ground & Remote and
Q ADJUST
mark for cutting/termination. Remove P500 before cut-
t i n g a n d t e r m i n a t i n g a l l w i r e s . C A U T I O N : s t r i p p i n g
w i r e s o v e r t h e c i r c u i t b o a r d m a y c a u s e p r o d u c t f a i l u r e .
+/– 18 dB
Make initial adjustment to input gain at your work bench.
Refer to the section "Input Sensitivity" on the reverse
s i d e .
Freq. Range
B
L
ALANCED
INE
20 – 200 Hz
Make initial adjustment at your work bench. Refer to the
200 – 2 KHz
section "Balanced Line" on the reverse side
2K – 20 KHz
P500
MOUNT THE
Re-install the P500 and make all wire connections. i.e.
Power, Ground, Remote and RCA i n p u t / o u t p u t s .
DOUBLE CHECK ALL CONNECTIONS
Check red LED, it should be on.
MAKE ALL EQUALIZATION ADJUSTMENTS
Refer to "P500 Tuning Sequence" in this "Reference"
ADJUST NOISE GATE THRESHOLD
Refer to "Activating the Noise Gate" on the reverse side
AFTER FINE TUNING THE SYSTEM
Remove protective covering from P500 and clean. A t t a c h
•
•
•
cover to base.
-
-
,
SHOOTING
A
Q U I C K
. T
,
-
H E C H A R T S P R O V I D E D
O F F E R A S I M
.
8
O
'
N P A G E
O F T H E
W N E R
S
O
'
R
L
.
W N E R
S
EFERENCE
OG
O
'
THOSE
SETTINGS
T O
T H E
W N E R
S
,
N T H E F U T U R E
A N Y SYSTEM E X P A N S I O N
.
S E Q U E N C E
:
COVER
P500:
P500:
:
:
:
AND MAKE ALL CONNECTIONS
!
P500:
TURN ON
:
(
):
IF USED
:
•
•
•
•
•
•
•
•
•
Need help?
Do you have a question about the P500 and is the answer not in the manual?
Questions and answers