TECHNICAL MANUAL Operating and Maintenance Instructions DATAGONE HARD DRIVE DEGAUSSER ZZ001203 / ZZ001204...
Page 2
RECOMMENDED THAT THIS EQUIPMENT SHOULD BE OPERATED FROM A SEPARATE SWITCHED ISOLATOR COPYRIGHT This document is the property of VS Security Products Ltd and it may not be reproduced, copied or exhibited to a third party without the written permission of VS Security Products Ltd.
Control Panel Using the Control Panel Operation Guide Error Messages Maintenance Cleaning Safety This document refers to DATAGONE degausser Part No ZZ001203 240/220volts 50Hz ZZ001204 110volts 60Hz ________________________________________________________________________________ VS SECURITY PRODUCTS ZZ001203 - ZZ001204 Page 3 of 13 Operating Instructions...
Waste electrical products should not be thrown away with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice. VS Security Products reserves the right to amend or modify the specifications and design criteria applying to these products ________________________________________________________________________________...
INTRODUCTION TO THE DATAGONE DEGAUSSER The DATAGONE is a high energy, hard drive eraser designed to offer complete and secure erasure of magnetic media including perpendicular recording hard drives. The DATAGONE is also capable of erasing data storage media including DLT, LTO, 8mm, DDS and more.
Power Wiring Power connection is made to the DATAGONE degausser in the form of a IEC type electrical lead (supplied). The user should ensure that their power supply meets those outlined on page four.
The LCD panel will display the progress, completion of the cycle and total number of degauss cycles completed. If the LCD repeatedly indicates a failure you should contact your nearest VS Security Products support department for further assistance.
6.1.2 Erasure of 2.5” & 1.8” Hard Drives and small media 4 and 4mm cassettes etc 1. To erase small hard drives 2.5”& 1.8” and also small media 8mm cassettes etc. they should be placed in the Small Media Carrier supplied with your DATAGONE. 2. Connect the unit to the power supply 3.
ERROR MESSAGES If the DATAGONE is not performing correctly the following error messages may be displayed. To validate the message switch the unit off and the on again using the power switch on the rear of the unit. ‘START UP ERROR’...
MAINTENANCE The DATAGONE Degausser contains extremely high electrical voltages and currents. For safety reasons, VS Security Products Ltd does not recommend that the covers be removed by anyone other than trained VS Security Products technicians. Cleaning the Input Optical Sensor The Input Sensor is an optical device that looks across the degauss chute to detect the media when it enters the unit.
Cleaning the Degauss Chute Media and hard drives that are dusty should be brushed off to remove loose dust and dirt before they are inserted into the Datagone. If the degauss chute becomes very dirty the drives may become stuck and not release after the degausser has fired.
Resetting the Circuit Breaker The DATAGONE Degasser is not equipped with any on-board fuses that require replacement. All the systems within the unit are protected by the circuit breaker which is located on the rear of the unit – this can be manually reset by the user.
Page 13
VS SECURITY PRODUCTS LIMITED VS AND ASSOCIATES 17 Pegasus Court 3160 Texas Hill Road North Lane Placerville Aldershot CA 95667 Hampshire GU12 4QP Tel: +44 (0) 1252 333577 Tel: 530-626-6924 Fax: +44 (0) 1252 333448 Fax: 530-626-6989 Email: sales@vssecurityproducts.com Email: ussales@vssecurityproducts.com...