Advertisement

Quick Links

JOOBY
AVENUE
luminaires series
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Avenue Series and is the answer not in the manual?

Questions and answers

Summary of Contents for JOOBY Avenue Series

  • Page 1 ™ JOOBY AVENUE luminaires series USER MANUAL...
  • Page 2 This user manual contains information about the JOOBY AVENUE luminaires (hereinafter referred to as "luminaires"), and sets the rules of exploitation and storage of the device. 1 GENERAL INFORMATION 1.1 Luminaires are compliant to the requirements of Directive LVD 2014/35/EU, Directive EMC 2014/30/EU, EN 60598-1, EN 60598-2-3, EN 60598-2-1, EN 60598-2-5.
  • Page 3 The manufacturer reserves the right to make changes in design and designation of luminaire options, which do not worsen products technical characteristics. 1.3 Product description, serial number, manufacturing date — see chapter 11. 1.4 Manufacturer: “TELECOMMUNICATION TECHNOLOGIES Ltd” Office address: 65026, Ukraine, Odessa, 1 Mytna Ploscha Phone: +380 48 759-09-09 E-mail: sales@jooby.com.ua, www.jooby.com.ua...
  • Page 4: About Product

    2 ABOUT PRODUCT 2.1 The luminaire is intended for illumination of streets, roads, highways, tunnels, bridges, parks, residential areas, industrial locations, public spaces, administrative buildings, parking lots, etc. The luminaire can be used for general internal illumination of production halls, warehouses, stores, auxiliary rooms, etc.
  • Page 5: Technical Specification

    3 TECHNICAL SPECIFICATION 3.1 Basic characteristics: – Limit voltage value, V – min 120, max 280 – AC frequency, Hz – 50 – Power factor – ≥0,95 – Colour rendering index (CRI) – ≥70 – Ingress protection according to EN 60529 –...
  • Page 6 Table 3.2 Intensity distribution Optical system type Average beam angle diagram 145°/65° figure 3.1 170°/120° figure 3.2 160°/80° figure 3.3 150°/70° figure 3.4 145°/80° S6/T1 figure 3.5 160°/50° S6/T2 figure 3.6 150°/60° S6/T3 figure 3.7 140° S6/T5s figure 3.8 160°/65° S6/Sc figure 3.9 45°...
  • Page 7 Figure 3.10 Figure 3.11 Figure 3.12 Figure 3.13 Figure 3.14 Figure 3.15 Figure 3.16 Figure 3.17 Figure 3.18 Figure 3.19 Figure 3.20 Figure 3.21 Figure 3.22 Figure 3.23...
  • Page 8 3.7 The correlated colour temperature in depending on luminaire options is encoded according to table 3.3. Table 3.3 Correlated colour temperature, K Luminaire option Rated value Tolerance intervals 3К Avenue …- ХХ-… 3000 2850 - 3250 4К Avenue …- ХХ-… 4000 3750 - 4250 5К...
  • Page 9: Delivery Set

    4 DELIVERY SET 4.1 The delivery set of the luminaire is specified in table 4.1. Table 4.1 Item Quantity Commentary Luminaire 1 pcs. М10х60 screw Avenue СХ-… 2 pcs. Т1 mount set 1 pcs. Avenue SX-…-T1 F1 mount set 1 pcs. Avenue SX-…-F1 F2 mount set 1 pcs.
  • Page 10 6 DESCRIPTION 6.1 Common description The luminaire has a module structure. The basic functional unit of luminaire is the light module, which consists of aluminum housing, LED light source, driver and secondary optical system (lens with accompanying parts). Depending on the housing type, there are two types of modules: “Console” and “Middle”. Depending on the embodiment, luminaires can contain from one to five light modules and one (Avenue СХ-...
  • Page 11 Figure 6.2 – Luminaire set on a L-type console Figure 6.3 - Luminaire set on a vertical pole 6.3 Suspended luminaires (Avenue SХ option) The suspended luminaire consist of Middle Light Modules (from 1 to 5 depending on the model) and two front sections. Suspended luminaires can be equipped with different mount types.
  • Page 12 Continuation of table 6.1 Compatible Code Title Description Figure luminaires Wide For mount on hard surface (wall, ceiling, Avenue S3-…-F3 floodlight, and metal construction). Adjustability: Avenue S4-…-F3 transversal slope angle ±90°. lyre Avenue S5-…-F3 Wide For mount on hard surface (wall, ceiling, Avenue S3-…-Fw floodlight, and metal construction).
  • Page 13 Figure 6.4 – Т1 mount Figure 6.5 – F1 mount...
  • Page 14 Figure 6.6 – F2 mount Figure 6.7 – F3 mount...
  • Page 15 Figure 6.8 – Fw mount Figure 6.9 – R (Rx2) mount...
  • Page 16 7 PRE-LAUNCH PROCEDURE 7.1 Unpack the luminaire and check its integrity and assembly correctness. 7.2 Power supply connection Connection to the power grid must be executed in accordance to national installation rules. An external three-core cable is used to connect the luminaire to the power supply. For correct connection be aware of the wires colour denotation: –...
  • Page 17 7.3.3 Luminaire installation order: – connect the power wire. The luminaire cable must be passed inside of the tube; – release fastening bolts and set the luminaire on L-type console or vertical pillar. Ensure that the cable was not damaged by squeezing between surfaces and cuts of tubes; –...
  • Page 18 Figure 7.2 – T1 mount installation Figure 7.3 – F1 mount installation...
  • Page 19 Figure 7.4 – F2 mount installation Figure 7.5 – F3 mount installation...
  • Page 20 Figure 7.6 – Fw mount installation Figure 7.7 – R (Rx2) mount installation...
  • Page 21: Maintenance

    8 MAINTENANCE 8.1 Luminaires require periodical (at least annual) preventive examination of functionality and fastening security. Discovered defects must be fixed. 8.2 Luminaires require cleaning at least twice a year, or when contaminated, with a water jet to remove dirt from between the heatsink ribs and dust from the optical element.
  • Page 22: Manufacturer Warranty

    11 ACCEPTATION CERTIFICATE Luminaire manufactured and accepted with obligatory observance of state standards, existing technical documentary, and claimed suitable for usage Technological Control Department Supervisor L.S. signature Surname and initials Date 12 MANUFACTURER WARRANTY 12.1 Manufacturer guarantees the quality of the product during specified warranty period for component parts, provided that the consumer fulfills all the requirements for storage, transportation and operation of the product during specified period of time.

Table of Contents