Download Print this page

Barthelme CHROMOFLEX III Series Instruction Manual page 8

Advertisement

Available languages

Available languages

11. DIP-SWITCHES
The selected Network and the Master
mode are set with a small 4-DIP switch
inside of the module. The top of the cover
can be removed easily.
Important: Do not touch the electronic
components; electrostatic discharge my
cause damage to them. Use something
spiky and non-conductive to turn the DIP
switches.
Important: All changes of the DIP switches
are recognised only after reset or power
on!
13. MODULE LAYOUT
NOTES
12. TECHNICAL DATA
Power supply:
7 - 26 volt (+ 5%), regulated. Important:
The power supply should have an equi-
valent pulse load. Unregulated or weak
power supplies may cause flickering or
malfunctions.
Module current (without LED lamps):
ca. 10 - 20mA
Operating temperature:
0°C - max. + 50°C (recommended: < =
30°C) (Use only in dry places with suffi-
cient air ventilation)
Radio frequency:
868.3MHz (licence-free in EC, Switzerland,
Norway and Iceland)
Modulation system:
The Chromoflex modules are based on a
digital system, named „Vector-Fractal-Mo-
dulation" or „VFM". This modulation sys-
tem was optimised for minimising load
on power supplies and has considerable
advantages compared to traditional sys-
tems. The modulation frequency is in the
range from 120Hz up to (max.) 240Hz. Pa-
tent pending.
Model „Chromoflex RC i350"
Pulsed constant current, ca. 350mA per
channel (3 channels). Highly efficient swit-
ching regulators are used.
Model „Chromoflex RC Stripe"
Pulsed constant voltage, maximum al-
lowed current: 4 ampere per channel (3
channels) - max. 12 ampere.
CONTACT
Josef Barthelme GmbH & Co. KG
Oedenberger Str. 149
90491 Nuremberg | Germany
T: +49 911 42 476 0
E: info@barthelme.de
www.barthelme.de
VERSION 06|2016
SUBJECT TO TECHNICAL
CHANGES.

Advertisement