Pin allocation DSL interface (X3)
Pin
Signal
3
2
1
1
Line A (DSL A)
2
Line B (DSL B)
3
Functional earthing and cable shield
A D V I C E
The SHDSL interface is designed as a 2 wire
interface. For an effective overvoltage protection it
is mandatory to connect the functional earthing as
well as the cable shield.
A D V I C E
Any SHDSL port supports auto-crossover detection
and correction, so signals A and B may be
interchanged.
A D V I C E
The signal lines are short-circuit protected and may
be connected while the module is powered and
working.
Serial Interfaces (Con0 - Con1)
The serial interfaces of the devices are signal
compatible to RS-232. The connector is a RJ-12 female
plug. The factory pre-sets are speed 57600 Baud,
no parity, 1 stop bit, no flow control. On delivery, the
management console can be accessed via the serial
interface.
Pin allocation serial interface RS-232 (RJ-12)
RS-232
Pin
Signal D irection Pin
1
DCD Output
2
CTS Output
3
RTS Input
6
1
4
GND -
5
RxD Output
6
TxD Input
Pin allocation serial interface RS-485 half duplex
(RJ-12)
RS-485 half duplex / 2-wire
Pin
Signal
1
2
3
B (-)
6
1
4
GND
5
6
A (+)
Pin allocation serial interface RS-485 full duplex
(RJ-12)
Power connector (X1)
The EDS500 devices are equipped with a wide range
power supply for voltages between 24 and 60 Volts DC
(power consumption see device label). The connector
is a 4-pin Phoenix plug with screw terminals.
Pin allocation power supply (X1)
RS-232 PC SUB-D9
Signal D irection
Extension interface (EXT)
1
DCD Input
The plug of the proprietary expansion bus is designed
8
CTS Input
as USB type B but uses a manufacturer specific
7
RTS Output
protocol.
5
GND -
The configuration parameters are stored directly
2
RxD Input
on the device. In addition, a configuration stick can
3
TxD Output
be connected to the expansion bus to save data
externally, in example to exchange defective devices
easily.
Direction
bi-directional
-
Alarm-Relay (X2)
The devices are equiped with a potential free alarm
bi-directional
output (relay with isolated switchover contact). This
output corresponds to a device alarm and is activated
when the device looses the power supply or the alarm
LED is constantly on. The reason for the signalling of
an alarm can be referenced in the system alarm table.
RS-485 full duplex / 4-wire
Pin
Signal
1
2
B (-)
3
B (-)
6
1
4
GND
5
A (+)
6
A (+)
Pin
Signal
1
24-60 V DC
1
2
3
4
2
Functional earth (internally wired to
pin 4)
3
GND
4
Functional earth (internally wired to
pin 2)
A D V I C E
Due to the internal overvoltage protection,
interrupt any connection to ground of the device
for the time of the measurement before you carry
out isolation measurement. This includes the
earthing of the hat rail as well as all shields of all
transmission lines and supply feedings. RJ-12 plugs
or RJ-45 plugs can establish earthing via the shield.
A D V I C E
Danger of damaging the device
Do not connect any USB devices!
Direction
Input
Output
-
Input
Output