This mode is especially adapted for the analysis of pressure curves and the survey of pressure peaks (with pre-trigger) GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, www.greisinger.de...
S56.0.01.6C-04 page 2 of 7 Index GENERAL ............................1 SAFETY REGULATIONS ........................ 2 SPECIFICATION ..........................3 DISPOSAL INSTRUCTIONS ......................3 OPERATING MODES ........................4 Standard - Mode ........................4 Fast - Mode ..........................4 GENERAL HANDLING INSTRUCTIONS ..................5 To connect/change sensors....................... 5 Altitude correction of the absolute pressure sensor ..............
S56.0.01.6C-04 page 3 of 7 5. The device must be switched off and must be marked against using again, in case of obvious mal- functions of the device which are e.g.: - visible damage - no prescripted working of the device - storing the device under inappropriate conditions for longer time When not sure, the device should be sent to the manufacturer for repairing or servicing.
S56.0.01.6C-04 page 4 of 7 5 Operating modes After restart the adapter is in the standard-mode. 5.1 Standard - Mode In this mode the GDUSB1000 acts like a portable measuring instrument of the GMH3xxx-series. It gives back the wanted measurement on request. For this purpose 4 measuring channels are allocated at the adresses 1 –...
S56.0.01.6C-04 page 5 of 7 6 General handling instructions 6.1 To connect/change sensors Only sensors of the GMSD or GMXD-serial are allowed to be used! If other sensors are used the adapter and the sensor may be destroyed. To change the sensor you have to disconnect the adapter. Sensors have to be connected before acti- vating the adapter.
S56.0.01.6C-04 page 6 of 7 7 Driver Installation 7.1 Windows Vista™, Windows XP and Windows 2000 For installation of the device drivers a user account with an administrator-authorisation is required. If you haven’t an appropriate authorisation please consult your system administrator. •...
S56.0.01.6C-04 page 7 of 7 8 Frequently asked questions (FAQ) 8.1 How to check whether the adaptor has been installed correctly and via which COM- port can I approach the installed adaptor? Start the Device-Manager: start \ settings \ control panel \ performance and maintenance \ system \ hard- ware and open the submenu “Ports (COM &...
Page 8
G38.0.01.6C-04 Operating Manual Windows™ - Operating Software GSOFT_USB for USB measuring adapter GDUSB1000 as of version 1.3 Contents: General Information ________________________________________________________________ 2 Software Operation _____________________________________________________________________ 2 Software License Agreement ______________________________________________________________ 2 Software Registration ___________________________________________________________________ 2 System Requirements____________________________________________________________________ 2 Software Installation ____________________________________________________________________ 2 Operating Software GSOFT_USB _____________________________________________________ 3 Screen Elements ________________________________________________________________________ 3 2.1.1...
G38.0.01.6C-04 GSOFT_USB – Operating Manual page 2 of 7 1 General Information 1.1 Software Operation This operating manual postulates basic knowledge of how to handle a personal computer with the operating system Windows™. If this is not existent it is recommended to make oneself familiar with the main features of Windows™ before installing this software (operating manuals, specialised literature, introductory courses etc.).
G38.0.01.6C-04 GSOFT_USB – Operating Manual page 3 of 7 2 Operating Software GSOFT_USB GSOFT_USB permits the handling of an USB measuring adapter of the GDUSB1000 series. This adapter enables a direct connection of a standard pressure sensor of the type GMSD/GMXD to the USB-interface of a personal com- puter.
G38.0.01.6C-04 GSOFT_USB – Operating Manual page 4 of 7 2.2.2 Sensor Data Window register “data“ register “comment“ register “instrument“ register “extras“ measurements table current status of the re- cording; start-/stop-condition number of data sets and period of recording 2.2.3 Start Recording When recordings are restarted, all data which have been recorded until that moment will be deleted!! If necessary read in and save important information or save the data on demand before a measurement- restart!
G38.0.01.6C-04 GSOFT_USB – Operating Manual page 5 of 7 Choice of the recording mode: Output: Cycle time: here you can decide in which intervals measuring points should be recorded. At the same time you can select which value will be displayed (measured value, min/max peak). Keep this in mind: at a cycle time of more or equal than 5ms all measured values will be selected automatically.
G38.0.01.6C-04 GSOFT_USB – Operating Manual page 6 of 7 2.3 Measurement Diagrams The loaded data of the measuring windows can also be displayed in diagrams. Select for this „Create new diagram“ in the menu point „Diagram“. Then a selection of all possible graphs will be displayed. Select the desired graphs and acknowledge your selection by pressing ‘Ok’.
G38.0.01.6C-04 GSOFT_USB – Operating Manual page 7 of 7 2.4 File Operation If you have saved data by selecting menu „file“ function “save“ or “save as“ you can re-load them at any time into the program to see the data or to analyse them. In that case please select “File / open...“...