Midi Solutions PROFESSIONAL Series Operating Instructions Manual

Midi Solutions PROFESSIONAL Series Operating Instructions Manual

8-output midi-controlled relay array

Advertisement

Quick Links

MIDI Solutions
PROFESSIONAL SERIES
R8
8-OUTPUT MIDI-CONTROLLED RELAY ARRAY
OPERATING INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROFESSIONAL Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Midi Solutions PROFESSIONAL Series

  • Page 1 MIDI Solutions PROFESSIONAL SERIES 8-OUTPUT MIDI-CONTROLLED RELAY ARRAY OPERATING INSTRUCTIONS...
  • Page 2 MIDI Solutions R8 Operating Instructions M426-100 2012 MIDI Solutions Inc. All rights reserved. MIDI Solutions Inc. PO Box 3010 Vancouver, BC Canada V6B 3X5 www.midisolutions.com...
  • Page 3 MIDI control. Each relay can be programmed to respond to a wide variety of MIDI messages, including Note, Control Change, Program Change, and System Exclusive messages, and programmed settings are retained even after power is removed from the unit. The MIDI Solutions R8 is MIDI-powered and requires no batteries or power supply to operate.
  • Page 4: Operation

    PROGRAMMING The R8 is programmed by sending it MIDI System Exclusive programming commands from a computer with a MIDI interface. These commands are described on the MIDI Solutions website, however the Programming Tools software creates these commands automatically (see www.midisolutions.com/support.htm).
  • Page 5 NOTE To program the R8 to respond to a Note message, send it the following System Exclusive programming command: F0 00 00 50 26 01 rr aa nn cc (pp) F7 is optional) All bytes must be in Hexadecimal format (see hexadecimal conversion table at end) = Relay (00 for Relay1 ...
  • Page 6: Control Change

    CONTROL CHANGE To program the R8 to respond to a Control Change message, send it the following System Exclusive programming command: F0 00 00 50 26 02 rr aa nn cc (tt pp) F7 ( and are optional) All bytes must be in Hexadecimal format (see hexadecimal conversion table at end) = Relay (00 for Relay1 ...
  • Page 7: Program Change

    PROGRAM CHANGE To program the R8 to respond to Program Change messages, send it the following System Exclusive programming command: F0 00 00 50 26 03 rr (aa pp) cc nn nn ... nn F7 aa pp ) is optional All bytes must be in Hexadecimal format (see hexadecimal conversion table at end) = Relay (00 for Relay1 ...
  • Page 8: System Exclusive

    SYSTEM EXCLUSIVE To program the R8 to CLOSE upon receiving a System Exclusive message, send it the following programming commands: F0 00 00 50 26 04 rr 01 (pp) F7 followed by F0 ... F7 is optional) where F0 ... F7 is the System Exclusive message the relay is being programmed to respond to (max.
  • Page 9: Midi Control Change Table

    MIDI CHANNEL TABLE The value in the programming commands is assigned according to the following table: MIDI Channel MIDI CONTROL CHANGE TABLE Decimal Hexadecimal Control Function Bank Select Modulation wheel or lever Breath Controller Undefined Foot controller Portamento time Data entry MSB Channel Volume Balance Undefined...
  • Page 10: Relay Contact Ratings

    WARRANTY MIDI Solutions Inc. warrants this product to be free from defects in material and workmanship for a period of one (1) year from date of purchase. This warranty is void if the product has been damaged by accident, misuse, alteration, unauthorized repairs or other causes not arising out of defects in material or workmanship.

This manual is also suitable for:

R8

Table of Contents