Hide thumbs Also See for Magma 200:

Advertisement

Quick Links

Quick troubleshooting
(Nothing will ever go wrong, but just in case here are some possible solutions)

Table of contents

1.
Errors, interlocks and safeties ............................................................................................ 2
1.1.
Magma 25 .................................................................................................................... 2
1.1.1.
Safety window ...................................................................................................... 2
1.1.
Diodes .......................................................................................................................... 2
1.1.1.
Interlocks .............................................................................................................. 2
1.2.
Chillers ......................................................................................................................... 3
1.2.1.
Water level ........................................................................................................... 3
1.2.2.
Temperature ......................................................................................................... 4
1.2.3.
Flow ...................................................................................................................... 4
1.3.
Deionising unit ............................................................................................................. 4
1.3.1.
Water flow ............................................................................................................ 4
1.3.2.
Water resistivity ................................................................................................... 4
1.4.
High voltage unit .......................................................................................................... 4
2.
No output from the Regenerative amplifier ...................................................................... 4
2.1.
Easy checks .................................................................................................................. 4
2.1.1.
There is something in front of the diagnostic cameras ....................................... 4
2.1.2.
Oscillator is not started ........................................................................................ 4
2.1.3.
Synchronisation signals ........................................................................................ 5
2.1.4.
Pump diode is not on ........................................................................................... 5
2.1.5.
Shutter is closed. .................................................................................................. 5
2.1.6.
Room temperature ............................................................................................... 5
2.1.7.
PulseShaper not set .............................................................................................. 6
2.1.8.
External devices .................................................................................................... 6
2.2.
Hard checks .................................................................................................................. 6
2.2.1.
Input seed pulse in the regen amplifier ............................................................... 6
3.
Device not responding ....................................................................................................... 7
3.1.
Compressor translation or rotation not responding ................................................... 7
3.2.
Motorised mounts in the amplifiers not responding .................................................. 7
1
Magma 200
Quick troubleshooting guide
Version 1.00
11 avenue de Canteranne, Cité de la Photonique - Bâtiment MEROP A 33600 Pessac - France
Headquarters
/
Capital social: 317 100 €
Amplitude Laser Group
/
Tel: +33 (0)5 56 46 40 60
Headquarters
Amplitude Laser Group
Tel: +33 (0)5 56 46 40 60
/
Siret 434 637 005 - APE 6420Z
/
Fax: +33 (0)5 56 46 06 94
/ info@amplitude-laser.com / www.amplitude-laser.com
/
11 avenue de Canteranne, Cité de la Photonique - Bâtiment MEROPA 33600 Pessac - France
Capital social : 320 925 €
/
/
SIRET: 434 637 005 - APE 6420Z
/
Fax: +33 (0)5 56 46 06 94
/
info@amplitude-laser.com
N°TVA Intracom: FR 70 434 637 005
/
/
N°TVA Intracom: FR 70 434 637 005
/ www.amplitude-laser.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Magma 200 and is the answer not in the manual?

Questions and answers

Summary of Contents for AMPLITUDE Magma 200

  • Page 1 Siret 434 637 005 - APE 6420Z Tel: +33 (0)5 56 46 40 60 Fax: +33 (0)5 56 46 06 94 / info@amplitude-laser.com / www.amplitude-laser.com Headquarters 11 avenue de Canteranne, Cité de la Photonique - Bâtiment MEROPA 33600 Pessac - France Capital social : 320 925 €...
  • Page 2 Siret 434 637 005 - APE 6420Z Tel: +33 (0)5 56 46 40 60 Fax: +33 (0)5 56 46 06 94 / info@amplitude-laser.com / www.amplitude-laser.com Headquarters 11 avenue de Canteranne, Cité de la Photonique - Bâtiment MEROPA 33600 Pessac - France Capital social : 320 925 €...
  • Page 3 Unscrew the desiccant plug, put the new one, close the lid, push the unit back in (pay attention not to bend the fibre when pushing) and reconnect the cables. The desiccant plugs can be bought form Amplitude. 1.1.1.5.
  • Page 4 If the high voltage power supply of the Pockels cell has the “Failure” LED on, power it down to let it cool down and check the cable connection to the Pockels switch on the Regen amplifier. If the failure still appears, contact Amplitude for service. 2. No output from the Regenerative amplifier This should be seen with the diode at 50 % or 53 %.
  • Page 5 Siret 434 637 005 - APE 6420Z Tel: +33 (0)5 56 46 40 60 Fax: +33 (0)5 56 46 06 94 / info@amplitude-laser.com / www.amplitude-laser.com Headquarters 11 avenue de Canteranne, Cité de la Photonique - Bâtiment MEROPA 33600 Pessac - France Capital social : 320 925 €...
  • Page 6 Magma 200 Quick troubleshooting guide Version 1.00 This is not an easy task and should not be attempted by the user; please contact Amplitude for service. 2.1.7. PulseShaper not set If the PulseShaper was powered down, it loses its configuration and by default blocks the pulses.
  • Page 7 If the beam is there, check that the power is around 50 mW. If no beam appears or if the power is too low, the oscillator needs servicing. If the oscillator’s output is as expected, then the PulseShaper needs servicing. Please contact Amplitude. 3. Device not responding “Have you tried turning it off and on again?”...
  • Page 8 Version 1.00 powered. If so, try restarting the embedded computer and the switch. If the problem is not solved, please contact Amplitude for further diagnostics. 11 avenue de Canteranne, Cité de la Photonique - Bâtiment MEROP A 33600 Pessac - France Headquarters Capital social: 317 100 €...

Table of Contents