HCVA/HCVAR Table of contents Safety notes........................3 Application area ........................3 Stroke-pushing force diagram .................... 3 Features..........................4 Technical data........................4 Dimensions for type HCVA ....................4 Connection for type HCVA in single mode ................. 5 Connection for type HCVAR in single mode ............... 5 Connection for type HCVA in synchro mode and Wind-/rain sensor ........
HCVA/HCVAR Safety Notes - Operating voltage 230VAC! - Connection must be carried out by authorized electricians. - It’s necessary to ensure that people keep away from the operation area of the drives. Danger of violent pressure in accessible area! - Use only in dry rooms. Application area - For opening and closing of facade and roof windows Stroke-pushing force diagram...
HCVA/HCVAR Features - Microprocessor controlled Bus synchronization. - HCVAR is incl. remote control - Max. 4 pcs. drives can be synchronized. (1 pcs. HCVAR can be synchronized with up to 3 pcs. HCVA, but max. 1 pcs. HCVAR per synchro set) - Push / Pulling, Opening / Closing Speed and Stroke length can be programmed.
230VAC / 50Hz Caution! The white and grey wire are only for changing parameters. Parameter change can only be made by Actulux or an authorized service and sales partner by Actulux. Do not connect the white and grey wire to 230V!
Caution! The white and gray wire are used for change parameters or for bus communication for synchro mode. Parameter change can only be done by Actulux or by an authorized Actulux service and sales partner. Note! Do not connect white and grey wire to 230V!
Caution! The white and gray wire are used for change parameters or for bus communication for synchro mode. Parameter change can only be done by Actulux or by an authorized Actulux service and sales partner. Note! Do not connect white and grey wire to 230V!
HCVA/HCVAR Mounting instructions Choice of brackets: Application Bracket set Item no. Screws* Outwards opening window, top hung HMB-HCV-01 390000 Inwards opening window, bottom and side hung HMB-HCV-02 390120 Skylight HMB-HCV-03 390130 *Select suitable screws according to frame material! Bracket set HMB-HCV-01 for top hung #390000 Maximum stroke lenght for this application is 600 mm...
350 mm 227 mm 600 mm 352 mm This Document contains proprietary data of Actulux A/S. No information, reproduction or use of any part there of may be used without written permission. Tolerances unless otherwise specified: ISO 2768-mL. Actulux A/S Phone int.: +45 98 57 40 90...
Pairing HCVAR with wireless wind / rain sensor It is possible to connect a wind / rain sensor wireless to the chain drive. (See our user manual for wind and rain sensor at www.actulux.com) Rain sensor # 111960 Wind- & rain sensor # 111961...
HCVA/HCVAR Warranty We refer to www.actulux.com Disposal Electrical equipment, accessories and packaging should be recycled for environment protection! Don’t dispose electrical equipment into household waste! Only for EU-Countries: According to the European guideline 2002/96/EG about waste electrical and electronic equipment and its implementation into national law, useless electrical and electronic equipment must be separately collected and recycled for environment protection.