Drain Master S Series Instruction And Operation Manual

Condensate auto drain

Advertisement

PRODUCT RANGE
▶ Auto Drain Trap (Level-sensor type)
DRAIN MASTER
● DRAIN MASTER S Auto Drain Trap (Solenoid valve type)
● DRAIN MASTER HP Auto Drain Trap for High Pressure (Max 60 bar)
● DRAIN MASTER B Auto Drain Trap (Ball valve type)
● DRAIN MASTER V Auto Drain Trap for Vacuum
● DRAIN MASTER T Auto Drain Trap (Timer type)
▶ Oil-water Separator
YUSOO-BREAKER
●Filter Type Oil-water Separator
▶ Emulsion Separator
ENVISOL
● Chemical Type Oil-water Separator
Subject to technical changes without prior notice, errors not excluded.
Edition : 09.2015
CONDENSATE AUTO DRAIN
DRAIN MASTER-S / HP
Instructions and operation manual
◆ Please read this manual before installation of DRAIN MASTER
◆ Functions of DRAIN MASTER are enabled properly only when the instructions herein are observed.
ISO 9001/14001/NRTL/CE
Model : DM-5S, DM-5, DM-5N, DM-15, DM-50,
DM-150, DM-500, DM-1500,
DM-15HP, DM-50HP, DM-150HP

Advertisement

loading
Need help?

Need help?

Do you have a question about the S Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Drain Master S Series

  • Page 1 ● Chemical Type Oil-water Separator Subject to technical changes without prior notice, errors not excluded. ◆ Please read this manual before installation of DRAIN MASTER Edition : 09.2015 ◆ Functions of DRAIN MASTER are enabled properly only when the instructions herein are observed.
  • Page 2: Table Of Contents

    Green ▶ Electrical installation must be performed by qualified technician. DM-15HP Blue ▶ DRAIN MASTER S/HP is activated only when it is connected to power. Green ▶ Always use authentic components provided by the Company for replacement to be DM-50HP Blue 1.2 / 60...
  • Page 3: Dimension

    DIMENSION DIMENSION DM-5S DM-5N DM-5 DM-15...
  • Page 4 DIMENSION DIMENSION DM-50 DM-500 DM-150 DM-1500...
  • Page 5 DIMENSION DIMENSION DM-15HP DM-150HP DM-50HP...
  • Page 6: Function

    FUNCTION INSTALLATION The condensate line must be installed separately. Fig.2 Fig.1 With linear pipe line, arrange the pipe Condensate through the feed line is accumulated in the housing. When the upper flow sensor detects the line so that condensate is separated condensate level and sends a signal with the electronic control device, the valve is activated to open the from air.
  • Page 7: Electrical Installation & Data

    ELECTRICAL INSTALLATION MAINTENANCE Trouble shooting Factor Solution ※ The feed line or the discharge Check these lines. ▶ No discharge of condensate line is closed or blocked. with the Test button ※ Defective PCB Replace the PCB. ※ Defective solenoid valve Replace the solenoid valve.
  • Page 8: Components

    COMPONENTS COMPONENTS DM-5S DM-5 Wearing part kits SP DM5 101 2, 8, 13, 31, 32, 33, 35, 37, 42 Wearing part kits SP DM5S 101 3, 6, 9, 12, 30, 31, 32, 34, 35, 37, 46 Housing SP DM5 102 1, 2, 5, 6, 8 Housing SP DM5S 103...
  • Page 9 COMPONENTS COMPONENTS DM-5N DM-15 Wearing part kits SP DM15 101 2, 8, 13, 31, 32, 33, 36, 37, 39, 49, 50 Wearing part kits SP DM5N 101 4, 11, 29, 30, 31, 33, 34, 36, 46, 47 Housing SP DM15 102 1, 2, 5, 6, 8 Housing Upper cover SP DM5N 103...
  • Page 10 COMPONENTS COMPONENTS DM-50 Wearing part kits SP DM50 101 2, 8, 13, 31, 32, 33, 36, 37, 39, 49, 50 DM-50 DM-150 Housing SP DM50 102 1, 2, 5, 6, 8 Cover Top SP DM50 103 8, 9, 10, 11, 12 Cover Bottom SP DM50 104 2, 3, 4...
  • Page 11 COMPONENTS COMPONENTS DM-1500 DM-15HP DM-15HP Wearing part kits SP DM1500 101 5, 10, 17, 35, 36 , 37, 40, 41, 43, 53, 55 Wearing part kits SP DM15 101 2, 8, 13, 31, 32, 33, 36, 37, 39, 49, 51 Housing SP DM1500 102 1, 5, 10, 15, 16...
  • Page 12 COMPONENTS COMPONENTS DM-50HP DM-150HP Wearing part kits SP DM50 101 2, 8, 13, 31, 32, 33, 36, 37, 39, 49, 51 Wearing part kits SP DM150 101 2, 8, 16, 34, 35, 36, 39, 40, 42, 52, 54 Housing SP DM150 102 1, 5, 6 Housing SP DM50 102...