Do you have a question about the ICP HMP-03 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for UTC ICP HMP-03
Page 1
Model: HMP-03 Manufactured by: UTC Canada Corporation ICP Division 3400, Industrial Boulevard Sherbrooke, Quebec J1L 1V8 INDIRECT OIL FIRED SWIMMING POOL Caution : Do not tamper with HEATER the unit or its controls. Call a qualified service technician. Save these instructions for future reference...
PART 1 INSTALLATION 1.1) DANGER, WARNING AND CAUTION A QUALIFIED TECHNICIAN MUST INSTALL THE INDIRECT OIL - FIRED SWIMMING POOL HEATER. The signal words DANGER, WARNING and CAUTION are used to identify levels of hazard seriousness. It is important that you understand their meaning.
Page 3
1.2) DELIVERY 1.3.4) Installation of the Outdoor Diffuser Kit Check the SWIMMING POOL HEATER carefully upon delivery for any The HMP-03 swimming pool heater must be installed with the Outdoor evidence of damage that may have occurred during shipping and Diffuser Kit model "GDK", manufactured by ICP (Canada), according to handling.
Page 4
1.7.2) Outdoor diffuser kit model GDK 1.6) OIL TANK INSTALLATION AND HOOK-UP With the outdoor-diffuser kit no draft regulator is needed and the The oil tank must be installed in accordance with local codes and maximum over fire draft should be +0.045" W.C. after 5 minutes of regulations and CSA Code B139.
PART 2 MAINTENANCE AND OPERATION We recommend that a qualified technician Check the electrical supply circuits (breakers); start-up and service the swimming pool heater. Check the burner electrode adjustments (refer to the burner instruction manual); Ensure that the heater and the system are Check if the pool thermostat is calling for heat;...
Page 6
2.6) START-UP AT THE BEGINNING OF THE WARNING SWIMMING SEASON Have the chimney and the connecting pipes swept (INSIDE At 60°C (140°F) hot water can produce third INSTALLATION ONLY). degree burns in 6 seconds; at 54°C (130°F) in 30 Have all heating surfaces cleaned if deemed necessary after a visual seconds.
Page 7
FIGURE 1 DNS-0527 Rev. B Automatic air vent Junction electrical box Outlet water temperature control (setting, max. = 130 Oil burner diff = 10 Pool thermostat Drain valve (at the back of the appliance) ON-OFF switch Ground terminal Green light, correct water level Observation door Red light, low water level Pool heater water outlet...
Page 8
PART 3 INFORMATION Serial number: Date of installation of the HMP-03: Service telephone - Day: Night: Dealer name and address: START-UP TEST RESULTS Nozzle: Pressure: lb/psi Burner adjustments: Primary air Fine air Draw Assembly Smoke scale: (Bacharach) Gross stack temperature: Ambient temperature: Chimney draft: "W.C.
Page 12
PARTS LIST Model : HMP-03 DNS-0540 Rev. B ITEM DESCRIPTION NUMBER ITEM DESCRIPTION NUMBER Tankless coil ass'y B02125 Top front panel ass'y (HMP-03-T only) B02148-02 Gasket, tankless coil B02113 Front door ass'y B02151 Heat exchanger ass'y B02131 Water leak pan B02117 Combustion chamber bottom insulation B00618-04...
Page 13
PARTS LIST Model : GDK-24 DNS-0557 Rev. A ITEM DESCRIPTION NUMBER COMMENTS Hex washer head self-drilling screw #1/4-14 x 1" F03G010 Stainless steel Diffuser ass'y B01504 Diffuser bracket ass'y B01506 Hex washer head self-drilling screw #8-18 x 1/2" F03G009 Quantity: 4, stainless steel Flue pipe casing B01486 Stainless steel flue pipe...