Frankford Arsenal INTELLIDROPPER 1082250 User Manual

Frankford Arsenal INTELLIDROPPER 1082250 User Manual

Electronic powder measure

Advertisement

INTELLIDROPPER
ELECTRONIC
POWDER MEASURE
Product #1082250
Instructions #1105521
Rev. A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INTELLIDROPPER 1082250 and is the answer not in the manual?

Questions and answers

dave
May 30, 2025

where is the on-off button

1 comments:
Mr. Anderson
May 30, 2025

The exact location of the on-off button on the Frankford Arsenal 1082250 is not specified in the provided context.

This answer is automatically generated

Scott JARMY
March 26, 2025

Will the power unit work on a 240-volt European system, please? Or do I need to get an alternate power unit? If so, what is the amperage?

1 comments:
Mr. Anderson
March 26, 2025

The Frankford Arsenal INTELLIDROPPER 1082250 uses a 12V DC power supply. The provided information does not specify whether the included power adapter supports 240V input. If the supplied adapter is only rated for 120V, an alternate power adapter compatible with 240V input and 12V DC output will be needed. The amperage rating is not specified in the provided information.

This answer is automatically generated

Tomas Gaupsas
February 4, 2025

Where to find the GO Button? .

Summary of Contents for Frankford Arsenal INTELLIDROPPER 1082250

  • Page 1 INTELLIDROPPER ELECTRONIC ™ POWDER MEASURE Product #1082250 Instructions #1105521 Rev. A...
  • Page 2 the INTELLIDROPPER™ Powder hopper cover Powder brush Powder hopper tube (2) 50g Calibration weights Clear air draft cover Powder pan Scale tray Powder tube empty spout Bubble level Independently leveling feet 12V DC power supply with cord (not shown) NOTICE: For ideal dispensing the INTELLIDROPPER™ Powder Measure should be used on a stable level surface in an area that has a well-regulated and stable temperature with minimal air movement or vibrations.
  • Page 3 Important Safeguards • Do not store powder in the hopper for long periods of time, this may ruin the device. • Do no use this device with black powder. This device is intended for smokeless powder only. • Do no shake, drop, overload unit, or use a power supply different than the one that is supplied. setting up the INTELLIDROPPER Using the provided 12V DC power supply, provide power to the device.
  • Page 4 Once the device has stabilized, minimum of 15 minutes, it may be calibrated. To calibrate the device perform the following: 1. Remove the pan from the tray. 2. Press the ZERO button on the screen of the device. 3. Press the CAL button on the screen of the device. a.
  • Page 5 At this point the device is ready to dispense. For optimized dispense times use our PATENT PENDING POWDER CAL feature. This optimizes the dispense rate of the device for each individual powder. To use our POWDER CAL feature 1. Fill the Powder tube with powder and replace the tube cover 2.
  • Page 6 BUTTON FUNCTION MODE: Adjusting the device from AUTO to MANUAL. a. When in AUTO the device will dispense automatically after the empty pan has been placed back onto the tray after a dispensing cycle. b. When in MANUAL, the user will have to press the DISPENSE/GO button in order for it to dispense a set target again.
  • Page 7 ® SYMBOL: Is shown when Bluetooth is activated BLUETOOTH and paired with your device. FRANKFORD ARSENAL ® POWDER INTELLIDROPPER APP FREE! Download the Powder Intellidropper App from online and Bluetooth® your Phone or Tablet directly to your Intellidropper™ Powder Measure.
  • Page 8 FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Table of Contents

Save PDF