Corporation shall not be held liable for damages resulting from such improper use. Limited Warranty Precision Digital Corporation warrants this product against defects in material or workmanship for the specified period under “Specifications” from the date of shipment from the factory. Precision Digital’s liability under this limited warranty shall not exceed the...
Model PDA1500 Logic Level Converter Instruction Manual INTRODUCTION The PDA1500 High VAC/VDC to Logic Level Converter is an easy to use DIN rail mounted device for converting high voltage signals into logic level signals for use as a digital input to a wide range of process control and display equipment.
Model PDA1500 Logic Level Converter Instruction Manual SPECIFICATIONS Except where noted all specifications apply to operation at +25°C. General CONFIGURATION Two latching pushbuttons for selection of output state inversion METHOD and cascade mode selection. No other programming required. INDICATORS One green power LED. Four red LED indicators to monitor live inputs on channels 1-4.
Page 7
Model PDA1500 Logic Level Converter Instruction Manual DIGITAL Four TTL Logic (5V) independent digital outputs. OUTPUTS OUTPUT LOGIC Output Low: 0 to 0.33 V LEVELS Output High: 4.4 to 5.0 V CASCADE MODE Typically used in Boiler applications to monitor for and detect fault conditions.
Model PDA1500 Logic Level Converter Instruction Manual SAFETY INFORMATION CAUTION WARNING Read complete instructions prior Risk of electric shock or personal injury. to installation and operation of the meter. WARNING Hazardous voltages exist within enclosure and at wiring connections. Installation and service should be performed only by trained service personnel.
Model PDA1500 Logic Level Converter Instruction Manual DIN Rail Mounting Instructions DIN Rail Mounting Requirements The converter requires a length of 35 mm “top hat” DIN rail 3.00" (76.3 mm) wide. The converter may be installed between other equipment on the same DIN rail without removing the other equipment.
Model PDA1500 Logic Level Converter Instruction Manual Removing the Converter from the DIN Rail Removing the converter from the DIN rail requires the use of a small slotted screwdriver or similar tool. Hazardous voltages exist within enclosure and at wiring connections. Installation and service should be performed only by trained service personnel.
Model PDA1500 Logic Level Converter Instruction Manual CONNECTIONS & SETUP Wiring & Connections All connections are made to fixed position screw terminal connectors located on the top and bottom of the enclosure. Use copper wire with 60°C or 60/75°C insulation for all line voltage connections.
Model PDA1500 Logic Level Converter Instruction Manual Connector Markings Connector markings are printed on the front of the enclosure near each terminal. These markings indicate the function of the connection terminal next to the labeling. Figure 1. Connector Markings Group Label Description OUTPUTS...
Model PDA1500 Logic Level Converter Instruction Manual Power Connections Power connections are made to the two terminals labeled PWR on Figure 2. 12-24 VDC is applied with the polarity shown by the + and - symbols. Figure 2. Power Connections Input Signal Connections High voltage input channel 1-4 signal connections are made to the terminals labeled CH1, CH2, CH3, and CH4 on Figure 3.
Model PDA1500 Logic Level Converter Instruction Manual Digital Output Connections Low voltage digital outputs 1-4 signal connections are made to the terminals labeled OUTPUTS 1, 2, 3, 4, and G on Figure 4. The terminal labeled G is the common for all four digital outputs. For input devices with a + and –...
Model PDA1500 Logic Level Converter Instruction Manual Mode Selection Latching Pushbuttons There are two latching pushbuttons located on the top of the unit within the enclosure. These are located next to the ON/OFF and H/L labels, inside the terminal connection openings. These pushbuttons are used to enable Cascade Mode and/or Inverter Mode.
Model PDA1500 Logic Level Converter Instruction Manual Output H/L Inverter Mode The H/L latching pushbutton is used to invert the output states. For example, in Normal Mode, when input channels CH1-CH4 detect high voltage, the corresponding output will provide an active high. When high voltage is not detected on an input, the corresponding output will provide an active low signal.
Model PDA1500 Logic Level Converter Instruction Manual LED INDICATORS LED Indicator Color Description POWER Green LED ON indicates unit is powered LED ON indicates high voltage is LIVE INPUTS present on corresponding input (1 - 4) channel (CH1 – CH4) LED ON if Inverted Mode is enabled INVERT Yellow...
Model PDA1500 Logic Level Converter Instruction Manual OPERATION The PDA1500 High Voltage AC/DC to Logic Level Converter accepts up to four high voltage input signals and outputs a TTL logic (5 V) signal representative of each input’s status (whether high voltage is present or not).
Model PDA1500 Logic Level Converter Instruction Manual Cascade Mode Cascade Mode is a special operation mode used for the monitoring of high voltage interlocks where one failure causes a failure of all monitoring points further down in the system. Examples of this include the many interlocks on boiler systems, where a single failure can cause a cascade of failures later in the system.
Model PDA1500 Logic Level Converter Instruction Manual Inverted Cascade Mode Inverted Mode may be applied to Cascade Mode. When the H/L pushbutton is latched in the recessed position, Inverted Mode is active. The outputs behave using the same logic as in Cascade Mode, but the output states are all inverted.
Model PDA1500 Logic Level Converter Instruction Manual Multiple Unit Cascade Mode Cascade Mode logic may be combined across multiple Logic Level Converters to monitor more than 3 alarm outputs (or 4 inputs). When wired together, output four (4) of a Logic Level Converter will monitor input CH4 and CH1 of the next Logic Level Converter wired in series with it.
Model PDA1500 Logic Level Converter Instruction Manual TROUBLESHOOTING The rugged design and simple configuration of the Logic Level Converter should make it unusual for the installer or operator to refer to this section of the manual. However, should a problem be encountered, the following tips may prove useful.
Page 24
Model PDA1500 Logic Level Converter Instruction Manual How to Contact Precision Digital For Technical Support please Call: (800) 610-5239 or (508) 655-7300 Fax: (508) 655-8990 Email: support@predig.com For Sales Support or to place an order please contact your local distributor or Call: (800) 343-1001 or (508) 655-7300 Fax: (508) 655-8990 Email: sales@predig.com...
Need help?
Do you have a question about the PDA1500 Series and is the answer not in the manual?
Questions and answers