Download Print this page

Zhendre SPF B Series User Manual

Split & multisplit wall mounted console floor/ceiling duct cassette, r410a inverter/r410a/r407c/r22

Advertisement

Quick Links

USER'S MANUAL
ENGLISH VERSION
SPLIT & MULTISPLIT
Wall Mounted – Console – Floor / Ceiling
Duct – Cassette
R410A INVERTER
SCI - SHI – SQI
DHI - THI – QHI – IMHI – IMMI – ICMI - IKMI
ASI – GSI – KSI
R410A
SCR – SHF – SHR – SQR - DHR – THR
ASR – GSR - KSR12B/18B - KSR24/36/48
R407C
SPFxxB– SPRxxB – SPFxxC – SQP
R22
SGF – SGR - ATF – ATR – GTF – GTR – KTF –KTR
EN
090317-NUT-SPLIT-MULTISPLIT-EN
1/24

Advertisement

loading

Summary of Contents for Zhendre SPF B Series

  • Page 1 USER’S MANUAL ENGLISH VERSION SPLIT & MULTISPLIT Wall Mounted – Console – Floor / Ceiling Duct – Cassette R410A INVERTER SCI - SHI – SQI DHI - THI – QHI – IMHI – IMMI – ICMI - IKMI ASI – GSI – KSI R410A SCR –...
  • Page 2 090317-NUT-SPLIT-MULTISPLIT-EN 2/24...
  • Page 3 PRELIMINARY INSTRUCTIONS • Please read all these instructions before switching the product on. • Contact an approved repair technician to install, repair and maintain this product. • If the power cable is damaged, replacement must be carried out by an authorised technician. •...
  • Page 4 1- GENERAL POINTS • This air conditioning unit is composed of an outdoor unit, an indoor wall/ceiling/cassette/ducted/vertical unit for split models, or several indoor units for multisplit models. • The outdoor unit (which includes the compressor) are designed to be installed outside the building. •...
  • Page 5 Keep firearms well away from Do not place the power cable near Do not use the power cable the appliance. to any apparatus that produces near to inflammable gas or heat. combustibles, such as diesel, benzene, solvents, etc. •Risk of fire. •This can cause electric shocks or •Risk of explosion and fire.
  • Page 6 3- COMMAND  INFRARED REMOTE CONTROL The different types of remote control that can be supplied with the products are shown below. Each indoor unit is delivered with an infrared remote control. Type : R51 Type : R11 Type: R05 A receiver located on a display panel on the front of the indoor unit (products of the wall, floor/ceiling, cassette and console type) or on the front of a separate control box (DUCT type product) receives the remote control infrared signal.
  • Page 7  RECEIVER (wall-mounted model SQR – SQI – SQP – SCI) This is located on the display panel on the front of the indoor unit Signal receptor  RECEIVER (wall-mounted model SCR) This is located on the display panel on the front of the indoor unit ...
  • Page 8  RECEIVER (Floor / ceiling model ATF - ATR - ACF) This is located on the display panel on the front of the indoor unit K = Signal receptor  RECEIVER (Floor / ceiling model ASR18A - ASR24A) This is located on the display panel on the front of the indoor unit ...
  • Page 9 DESCRIPTION OF BUTTONS Type : R51M/E Type : R11HG/E Type: R05/BGE 1 TEMP  This reduces the set temperature. 2 MODE This enables the operating mode to be selected. Each time the button is pressed, the operational mode changes, in the following order: AUTO (automatic) ->...
  • Page 10 6 LOCK This locks the remote control settings. Pressing this button a second time deletes this function. 7 TIMER OFF This allows the user to programme a duration after which time the product stops. 8 TIMER ON This allows the user to programme a duration after which time the product starts. 9 ON/OFF This starts or stops the product.
  • Page 11  REMOTE CONTROL DISPLAY          Type : R51 Type R05          Type : R11 1 Infrared transmission indicator This indicator appears when the remote control transmits a signal to the receiver. The receiver then emits a BEEP to acknowledge the signal.
  • Page 12  REMOTE CONTROL INSTRUCTIONS • Insertion and replacement of batteries - The Infrared remote control requires two R03 type batteries. -When using for the first time, insert the two R03 batteries (provided with the product) into the compartment in the back of the remote control by opening the sliding cover.
  • Page 13 Note: -To limit the effect of the dehumidification mode on the room temperature, the product alternates the cooling (COOL) mode with the fan only (FAN) mode. • Selecting the fan speed By pressing the FAN SPEED button on the remote control, the fan speed of the indoor unit can be selected in the following order: automatic speed ->...
  • Page 14 • Override (MANUAL / AUTO COOL) If the remote control is out of order or lost, the user can operate the product manually by using the override button: - On ducted, cassette, floor/ceiling or console products, this button is located on the indoor unit display panel (m-F-O-3);...
  • Page 15 • Display panel (wall-mounted model) This is located behind the front panel of the indoor unit. = Automatic operating mode indicator "AUTO" = Hot start or "DEFROST" indicator (heating mode) = Set temperature display (and default temperature on some models) = Operational indicator "OPERATION"...
  • Page 16 • Display panel (Floor/Ceiling models ACF / ATF / ATR) This is located at the top centre of the front panel of the indoor unit. = Infrared receiver = “OPERATION“ Operating status indicator = “TIMER” Timer setting indicator = Indicator for warm start-up or defrosting “DEFROST” (heating mode) = Indicator for unit safety mode (see self-diagnosis) = Manual start up button (override) 5- INSTRUCTIONS FOR USE...
  • Page 17 • Cassette model The automatic air outlet vents and sweeping vents must be carefully positioned: - A mechanical vent enables the airflow to be directed downwards. - This vent is controlled by the remote control (see above). Note: - Do not attempt to move the indoor unit mechanical vent manually. - Do not operate the indoor unit with the mechanical vent in the closed or almost closed position (loss of efficiency or risk of safety hazard).
  • Page 18 6- MAINTENANCE IMPORTANT: before cleaning the indoor unit, ensure that the product is switched off.  Use a dry, clean cloth to clean the plastic parts of the indoor unit and the infrared remote control.  A lightly dampened cloth can be used to clean the indoor unit if it is very dirty. ...
  • Page 19 • Cleaning the filters - Clean the filters with a vacuum cleaner or warm soapy water. - Rinse the filters in clean water and dry them at room temperature (do not dry in the sun or near a fire). -Replace the filters using the opposite process to the one use to dismantle them. -Ensure that the filters are repositioned as they were before dismantling;...
  • Page 20 7- DIAGNOSIS WARNING If one of the following phenomena occurs, stop the product immediately (OFF), unplug the electric cable immediately (circuit-breaker) and contact the nearest approved technician. The operating indicator "OPERATION" or other indicator on the display panel is flashing rapidly (5 times per second) and this flashing persists even when the power is switched off and on again and the product has been left to operate for more than 3 minutes after carrying out this action.
  • Page 21 NOTE __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________...
  • Page 22 Information provided in this documentation can be modified without prior notice. Information that was not available when this documentation went to press may be integrated later. The most recent updates can be consulted on www.zhendre.com 090317-NUT-SPLIT-MULTISPLIT-EN 22/24...
  • Page 23 090317-NUT-SPLIT-MULTISPLIT-EN 23/24...
  • Page 24 122, avenue des Pyrénées – BP82 – 33883 Villenave d’Ornon Cedex – France WEB : www.zhendre.com 090317-NUT-SPLIT-MULTISPLIT-EN 24/24...