  • Page 1 Programming Instructions Entry Controller EC 602-02...
  • Page 2: Table Of Contents

    Contents General remarks Key card Input units • Card input Programming/Operator interface • Relay selection Circuit diagram relating to • Gateway selection the programming examples • Time control Programming example • Subsequent read-in with 1 COM 611-... Programming example Key button with 1 ELM 611-...
  • Page 3 Display Display after switching on the EC 602-... After appr. 7 secs. Continuous display SSS Siedle EC 602-02 V2.xx Remark: The system is only operational if a continuous display is visible. Note If no input is made for longer than 10 minutes in a programming menu, the EC 602-...
  • Page 4: Input Units

    Input Units Address setting respective BCD switch for address COM 611-... setting. COM 611-... and/or ELM 611-... ELM 611-... and/or FPM 611-... FPM 611-... and/or DRM 611-... units combined DRM 611-... in a door station are each given the All COM 611-..., ELM 611-..., same address.
  • Page 5: Programming/Operator Interface

    Programming/Operator Interface Explanation of Symbols and Button Functions Access to the keypad and the display The lid of the housing can be opened by pulling at the upper edge. The display and keypad are located under the housing lid. Button functions Scroll buttons For scrolling forward and back between and in the programming menus, and for...
  • Page 6: Circuit Diagram Relating To The Programming Examples

    Circuit Diagram relating to the Programming Examples...
  • Page 7: Programming Example

    1. The door Terminals W0 and W2 (n.o. release is to remain switched on contacts) Continuous display SSS Siedle EC 602-02 V2.xx Use the programming button to Press the programming button access the main menu. Display SYSTEM...
  • Page 8 Using the cancel button, return to Press the cancel button the Code menu. Display CODE = Next OK = Prog Using the cancel button, quit the Press the cancel button programming level. Continuous display SSS Siedle EC 602-02 V2.xx The programming sequence is now completed.
  • Page 9: Programming Example With 1 Elm 611

    • Please number through the secs. EKC 601-... and/or EK 601-... you wish to read in starting with no. 001. Continuous display SSS Siedle EC 602-02 V2.xx Use the programming button to Press the programming button access the main menu. Display SYSTEM = Next...
  • Page 10 Key Card menu using the cancel button. Display Key card = Next OK = Prog Use the cancel button to quit the Press the cancel button programming level. Continuous display SSS Siedle EC 602-02 V2.xx The programming sequence is now completed.
  • Page 11: Programmable Menu Points

    Programmable Menu Points Programmable Programming Default Menu points possibilities setting System Language German, English German Relay function L (local), G (global) Gateway funct. 4 gateways A,B,C,D – – Changing the code 1-8-digit code – – Disable time 1-59 minutes – – Code Code input max.
  • Page 12: Programming Overview

    Programming Overview SSS Siedle EC 602-02 V2.xx wrong Enter code Code input CODE REQUEST necessary? Code..._ with and confirm with right SYSTEM CODE KEY CARD (only accessed if ELM 611- ... is connected) Language Code input Card input Relay function...
  • Page 13 Programming points marked with * only appear if the relevant conditions have been programmed in the System menu. Programming points marked with ** only appear if the relevant functions have been entered. KEY BUTTON TIME DELETE INFORMATION Relay selection Relay Delete Display code Relay 12...
  • Page 14: Inputs

    2. Code request Continuous display SSS Siedle The code request is accessed by EC 602-02 V2.xx pressing the programming button. Press the programming button If no code has been assigned or the Display if no code has been...
  • Page 15 System: Language Explanation of terms Language programming point: Operator prompting can optionally The System menu contains the Operator prompting is set as be set for English. following programming points: standard in the German language. • Language For German programmers, the •...
  • Page 16: System

    System: Relay function Relay function next menus. For this reason, a This programming point determines change of function also leads to a the function of the relays change in the next menus when (local/global function). assigning individual codes, EKC/ The function defined here is EK 601-...
  • Page 17 Sole operation of EC 602-... input units can be connected 8 input units can be connected. without ECE 602-...: (COM/ELM/FPM/DRM 611-...) In the case of local (L) programming However, if at least one of the relays of the relays, a maximum of 2 is globally programmed (G) up to On/Off function: the release time must be...
  • Page 18: Gateway Function

    System: Gateway Function Gateway function: The switching sequence can be Gateways can be initiated It is possible to implement a defined at will. The relay placed first irrespective of local/global maximum of 2 gateways (A, B) with in the switching sequence (Out 1) programming of the involved relays the EC 602-...
  • Page 19 Display Funct. Out 1/Out 2 Gateway B To define additional gateways, repeat the previous steps. If all the possibilities for gateway Display Changing the code formation have been utilized, after = Next OK = Prog confirming with the programming button, the following display appears: button scrolls forward button scrolls back...
  • Page 20: Changing The Code

    System: Changing the Code Disable Time Changing the code Display Changing the code If required, this programming point = Next OK = Prog can be used to define a code with 1 - 8 digits. Use the programming button to Press the programming button access the code programming level.
  • Page 21 Enter the units for the disable time Continue to press the scroll button by pressing the scroll button if until the required units value has necessary several times. been entered for the disable time. To enter the tens, change the cursor Press the cursor button position using the cursor button.
  • Page 22: Code

    Code: Code Input Code The programming points marked Double assignment of codes is not The Code menu contains the with * are included in the possible. following programming points: programming point „Code input“ If, for example, code 01 has been •...
  • Page 23: Card Input

    Code: Card Input Relay Selection Display = New OK = Save Code 01 Use the cursor buttons to scroll to Press the cursor button the next position. Display = New OK = Save Code 01 For the remaining digits of the code Display = New OK = Save...
  • Page 24: Gateway Selection

    Code: Gateway Selection, Time Control Display without ECE 602-... Gateway Gateway selection Code 01 Display with ECE 602-... Gateway A B C if a gateway has been programmed Code 01 in the System menu under the programming point „Gateway Starting from the display, it is the cursor to the relevant position funct.“.
  • Page 25 Key Card: Card input Key card The programming points marked The „Gateway selection“ The Key card menu is only accessed with * are included in the program- programming point only appears if if at least 1 ELM 611-... is ming routine for the programming at least one gateway has been connected.
  • Page 26 Key Card: Relay Selection, Gateway Selection Relay selection Display without ECE 602-... Relay Card 001 Display with ECE 602-... Relay 1 2 3 4 5 6 7 8 Card 001 If you do not wish to assign card 001 to any relay, press the programming button Starting from the display, it is using the cursor button to the...
  • Page 27 Key Card Gateway Selection, Time Control Assigning card 001 to gateway A Press the scroll button Display without ECE 602-... Gateway Card 001 Display with ECE 602-... Gateway A B C D Card 001 Use the programming button to save Press the programming button.
  • Page 28 Key Card: Subsequent Input of further EKC/EK 601-... units Subsequent input of further Display Key card EKC/EK 601-... units = Next OK = Prog Programming example: Pressing the programming button Press the programming button causes the programming point „Card input“ to appear. Display Card input = Next...
  • Page 29: Key Button

    Key Button Relay Selection Key button The Key button menu contains the automatically accessed there. In the Key button menu, user rights following programming points: However, they can be manually are defined for the internal key • Relay selection accessed outside this programming button in the COM 611-...
  • Page 30: Gateway Selection

    Key Button Gateway Selection, Time control Use the programming button to save Press the programming button your entry. Display Disable with Inp. 1 if no gateway has been programmed Card 001 in the System menu under „Gateway funct.“. Gateway selection Display without ECE 602-...
  • Page 31: Ok = Prog

    Key Button Display without ECE 602-... Relay External or display with ECE 602-... Relay 1 2 3 4 5 6 7 8 External The external key buttons are now released as required. This is performed using the same sequence as for the internal key buttons. The displays differ only in one point: Instead of the designation „Internal“, the word „External“...
  • Page 32: Time

    Time Time A default switching time of 3 The delay time is the time period In the Time menu, the switching seconds is set for relay 1 and 2. between switching start of the 1st times for the relays and the delay These can be changed in increments and 2nd relays in a gateway times for the gateways are defined.
  • Page 33 Time The switching times for further Display Relay relays are programmed using the = Next OK = Prog same method. After programming the switching time for the last relay, the following display appears. or display if a gateway has been Gateway programmed in the System menu = Next...
  • Page 34: Deletion

    Deletion Deletion The Delete menu contains the * These programming points only In the Delete menu, it is possible to following programming points appear if the relevant data has been delete the codes, EKC/EK 601-... and programmed. gateways. • Delete code word* The menu can only be accessed if •...
  • Page 35 Deletion If there are several codes available, the next code appears in the display. Otherwise the next programming point appears, e.g. „Delete card“. For additional deletion processes, the sequence described above applies correspondingly. Quit the programming level using Press the cancel button the cancel button.
  • Page 36: Information

    Information Information In the Information menu, the programming features of codes and the EKC/EK 601-... can be requested. The Information menu contains the following programming points: • Show code • Show card Example Display INFORMATION = Next OK = Prog Pressing the programming button Press the programming button causes the „Show code“...
  • Page 37: Ek 601

    Information Display without ECE 602-... Gateway Code XX Display with ECE 602-... Gateway A B C D if a gateway has been programmed Code XX in the System menu using the programming point „Gateway Depending on the programming funct.“ configuration, the gateway assignments are indicated in the bottom line of the displays.
  • Page 38 Information Further request points of the request procedure for EKC/EK 601-... correspond to those for requesting the code. Use the cancel button to return to Press the cancel button the initial display. Display INFORMATION = Next OK = Prog button scrolls forward button scrolls back Programming can be continued at any time using the cancel button...
  • Page 39: Reset

    If you really wish to delete the data, Press the programming button press the programming button within 5 seconds. The following display appears: Display SSS Siedle Please wait After a completed reset cycle, the Basic display SSS Siedle basic display appears again. EC 602-02 V2.xx...