Summary of Contents for Stahl EC-710 Series

  • Page 1 Operating Instruction Fix Cameras EC-710-xxx Operating instruction version: 02.00.11 Issue: 08.09.2020...
  • Page 2: Disclaimer

    Trademarks The terms and names used in this document are registered trademarks and / or products of the companies in question. Copyright © 2020 R. STAHL HMI Systems GmbH. Subject to alterations.  Page 2 of 28 R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020...
  • Page 3: Specific Markings

    ! Warnings Caution ! In ambient temperatures exceeding +45 °C the surface of the devices may heat up. Caution when touching !  R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020 Page 3 of 28...
  • Page 4: Table Of Contents

    12.3 EC-710-xxx lens coverage 12.3.1 Horizontal lens coverage in actual figures Maintenance, service 13.1.1 Servicing Troubleshooting Disposal 15.1 RoHS directive 2011/65/EC Declaration of EC conformity 16.1  Page 4 of 28 R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020...
  • Page 5 Table of contents Operating Instructions EC-710-xxx 16.2 Control Drawing NEC / CEC Release Notes  R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020 Page 5 of 28...
  • Page 6: Preface

    Glass reinforced polyamide, survives torque test: 50 Nm at -40 °C ... +75 °C Power 12 VDC +/- 10%, consumption 250 mA heater ON, 85 mA heater OFF  Page 6 of 28 R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020...
  • Page 7: Conformity To Standards

    The IECEx certification is listed below the following number: Certificate number: IECEx KEM 09.0039 X You can access all IECEx certificates on the official DOCUMENTATION website of the IEC under their certificate number. http://iecex.iec.ch/iecex/iecexweb.nsf/welcome?openform.  R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020 Page 7 of 28...
  • Page 8: Eac

    Ex m IIC T4 Gb Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups E, F, G Class III, Division 1  Page 8 of 28 R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020...
  • Page 9: Permitted Maximum Values

    EC-710-081. NOTICE Both types of cameras (EC-710-081 and EC-710-090) have the same real horizontal viewing angle from 81°.  R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020 Page 9 of 28...
  • Page 10: Safety Advice

    -40 °C <+ 75 °C for T4 and T125°C -40 °C <+ 50 °C for T5 and T100°C -40 °C <+ 35 °C for T6 and T85°C  Page 10 of 28 R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020...
  • Page 11: Electrical Data

    The breaking capacity of the fuse must cover the short circuit current of the power supply. Please look also to the special conditions mentioned in the EC type NOTICE examination certificate !  R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020 Page 11 of 28...
  • Page 12: Assembly And Disassembly

    Government Safety Association) and the BetrSichVer (Betriebssicherheitsverordnung - German Regulation of Workplace Safety). 11.2 Mechanical dimensions Diameter 55 mm 11.2.1 Mounting diagram: M6 x 20/25  Page 12 of 28 R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020...
  • Page 13: Mechanical Installation

    The colour camera can point in any direction. Please note the NOTICE camera's position. To help you identify the correct position the top of the camera is marked by a spot inside the front window.  R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020 Page 13 of 28...
  • Page 14: Operation

    (black) Mirror * (orange) (green) For the mirror function to work the orange wire needs to be NOTICE bridged to the red wire (+ 12 VDC).  Page 14 of 28 R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020...
  • Page 15: Bend Radius

    The camera itself must be incorporated in the system's overall ATTENTION potential equalization. For this, connect a grounding cable to the camera and connect the cable to the system's potential equalization.  R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020 Page 15 of 28...
  • Page 16: Ec-710-Xxx Lens Coverage

    The EC-710 camera types have a different horizontal lens coverage due to their different horizontal viewing angles. The drawings below are intended to help you choose the suitable camera version (using the three examples) for your application.  Page 16 of 28 R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020...
  • Page 17: Horizontal Lens Coverage In Actual Figures

    For this example, this would be the EC-710-070.  R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020 Page 17 of 28...
  • Page 18: Maintenance, Service

    Repairs may only be carried out by specially trained staff who are familiar with all basic conditions of the applicable user regulations and – if requested – have been authorized by the manufacturer.  Page 18 of 28 R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020...
  • Page 19: Disposal

    2011/65/EC, extends its area of application to all electric and electronic products. The cameras are conform with the requirements from RoHS directive 2011/65/EU, dated 03.01.2013.  R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020 Page 19 of 28...
  • Page 20: Declaration Of Ec Conformity

    Operating Instructions EC-710-xxx Declaration of EC conformity 16 Declaration of EC conformity 16.1  Page 20 of 28 R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020...
  • Page 21 Declaration of EC conformity Operating Instructions EC-710-xxx 16.2  R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020 Page 21 of 28...
  • Page 22 Operating Instructions EC-710-xxx Declaration of EC conformity  Page 22 of 28 R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020...
  • Page 23 Control Drawing NEC / CEC Operating Instructions EC-710-xxx 17 Control Drawing NEC / CEC  R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020 Page 23 of 28...
  • Page 24  Changing section "Certificates" now tabular listing  Addition of notice "Documentation" according to IECEx  Addition of type code and –table  Addition of EAC declaration of conformity  Formal changes  Page 24 of 28 R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020...
  • Page 27 Release Notes Operating Instructions EC-710-xxx  R. STAHL HMI Systems GmbH / OI_Camera_EC_710-xxx_en_V_02_00_11.docx / 08.09.2020 Page 27 of 28...
  • Page 28 R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D 50829 Köln (Sales Support) +49 221 768 06 - 1000 (Technical Support) +49 221 768 06 - 5000 +49 221 768 06 - 4100 (Sales Support) sales.dehm@r-stahl.com (Technical Support) support.dehm@r-stahl.com r-stahl.com exicom.de...